This manuscript aims to explore the hemocompatibility of titanium surfaces for achieving enhanced implant life. The surface treatment techniques investigated have shown that different surface properties can be tuned to improve hemocompatibility.
In the midst of a huge demand for high-precision miniaturized medical implants made up of potential biomaterials, the biomedical Ti-6Al-4V alloy meets the uncompromising standards for longevity, biocompatibility, and sterilizability required to interact with living cells in medical settings. This research tailored the existing capabilities of a traditional micro-electric discharge machining (µ-EDM) setup by adding 0, 2, 4, 6, 8, and 10 g/l bioactive zinc powder particle concentrations (PPCs) to the dielectric. A copper and brass micro-tool electrode (C-µ-TE and B-µ-TE) was employed in association with each PPC. Experiments were executed using the one-variable-at-a-time (OVAT) approach. Machining time and dimensional deviation were chosen as the response variables of Zn powder mixed-micro-EDM (Zn-PM-µ-EDM). According to the analytical findings, the combination of C-µ-TE and 6 g/l Zn PPC achieved 23.52%, 3.29%, and 17.96% lesser machining time, dimensional deviation, and recast layer thickness, respectively, compared to the B-µ-TE. The detailed study of this surface endorsed a significant modification in terms of improved recast layer thickness (26.44 µm), topography (Ra = 743.65 nm), and wettability (contact angle < 90 deg), suggesting its dental application. In addition, the observation of ZnO and TiO in X-ray diffraction and appealing in vitro cytocompatibility encourage the subsequent biological and therapeutic studies to validate the anticipated antiviral activity of the modified Ti-6Al-4V alloy surface against coronavirus (COVID-19).
This study investigated the influence of parameters such as pH condition, polyelectrolyte concentration, polymer ratio, and order of addition of the commercial polyelectrolytes chitosan and iota-carrageenan (ι-carrageenan) on the formation of polymeric nanoparticles in suspension (coacervates). A preliminary purification step of the polymers was essential for obtaining stable nanoparticles with small sizes as impurities, particularly metal ions that interfere with complexation, are removed by dialysis. Microparticles (13.5 μm in dry diameter) are obtained when aliquots of chitosan solution are poured into the ι-carrageenan solution. In general, an excess of chitosan results in the formation of agglomerated particles. The addition of an aliquot of ι-carrageenan solution (30 mL at 0.6 mg/mL and pH 4.0) to the chitosan solution (6.0 mL at 0.3 mg/mL and pH 4.0) leads to dispersed nanoparticles with a hydrodynamic radius of 278 ± 5 nm, a zeta potential of −31 ± 3 mV, and an average dry diameter of 45 ± 11 nm. The hydrodynamic radius increases as the pH rises. The partial deprotonation of ι-carrageenan chains enhances the interaction with water molecules, causing the particles to swell. These findings contribute to the fundamental understanding of polyelectrolyte complexation processes in aqueous suspension and provide insights for developing stable nanomaterials for potential practical applications.