Vasja Plesec

Mr. Vasja Plesec

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 May 2024 in Polymers
Verified
Journal Article
Open access
PDF file
VSVukasin Radovan Slavkovic
Vukasin Radovan Slavkovic
BHBlaž Hanželič
Blaž Hanželič
VPVasja Plesec
Vasja Plesec
Strahinja MilenkovićStrahinja Milenković
Strahinja Milenković
GHGregor Harih
Gregor Harih
This study investigated the thermomechanical behavior of 4D-printed polylactic acid (PLA), focusing on its response to varying temperatures and strain rates in a wide range below the glass transition temperature (Tg). The material was characterized using tension, compression, and dynamic mechanical thermal analysis (DMTA), confirming PLA’s strong dependency on strain rate and temperature. The glass transition temperature of 4D-printed PLA was determined to be 65 °C using a thermal analysis (DMTA). The elastic modulus changed from 1045.7 MPa in the glassy phase to 1.2 MPa in the rubber phase, showing the great shape memory potential of 4D-printed PLA. The filament tension tests revealed that the material’s yield stress strongly depended on the strain rate at room temperature, with values ranging from 56 MPa to 43 MPA as the strain rate decreased. Using a commercial FDM Ultimaker printer, cylindrical compression samples were 3D-printed and then characterized under thermo-mechanical conditions. Thermo-mechanical compression tests were conducted at strain rates ranging from 0.0001 s−1 to 0.1 s−1 and at temperatures below the glass transition temperature (Tg) at 25, 37, and 50 °C. The conducted experimental tests showed that the material had distinct yield stress, strain softening, and strain hardening at very large deformations. Clear strain rate dependence was observed, particularly at quasi-static rates, with the temperature and strain rate significantly influencing PLA’s mechanical properties, including yield stress. Yield stress values varied from 110 MPa at room temperature with a strain rate of 0.1 s−1 to 42 MPa at 50 °C with a strain rate of 0.0001 s−1. This study also included thermo-mechanical adiabatic tests, which revealed that higher strain rates of 0.01 s−1 and 0.1 s−1 led to self-heating due to non-dissipated generated heat. This internal heating caused additional softening at higher strain rates and lower stress values. Thermal imaging revealed temperature increases of 15 °C and 18 °C for strain rates of 0.01 s−1 and 0.1 s−1, respectively.

28 February 2023 in Materials
Verified
Journal Article
Open access
PDF file
VPVasja Plesec
Vasja Plesec
JHJani Humar
Jani Humar
Polona Dobnik DubrovskiPolona Dobnik Dubrovski
Polona Dobnik Dubrovski
GHGregor Harih
Gregor Harih
Lower-limb prosthesis design and manufacturing still rely mostly on the workshop process of trial-and-error using expensive unrecyclable composite materials, resulting in time-consuming, material-wasting, and, ultimately, expensive prostheses. Therefore, we investigated the possibility of utilizing Fused Deposition Modeling 3D-printing technology with inexpensive bio-based and bio-degradable Polylactic Acid (PLA) material for prosthesis socket development and manufacturing. The safety and stability of the proposed 3D-printed PLA socket were analyzed using a recently developed generic transtibial numeric model, with boundary conditions of donning and newly developed realistic gait cycle phases of a heel strike and forefoot loading according to ISO 10328. The material properties of the 3D-printed PLA were determined using uniaxial tensile and compression tests on transverse and longitudinal samples. Numerical simulations with all boundary conditions were performed for the 3D-printed PLA and traditional polystyrene check and definitive composite socket. The results showed that the 3D-printed PLA socket withstands the occurring von-Mises stresses of 5.4 MPa and 10.8 MPa under heel strike and push-off gait conditions, respectively. Furthermore, the maximum deformations observed in the 3D-printed PLA socket of 0.74 mm and 2.66 mm were similar to the check socket deformations of 0.67 mm and 2.52 mm during heel strike and push-off, respectively, hence providing the same stability for the amputees. We have shown that an inexpensive, bio-based, and bio-degradable PLA material can be considered for manufacturing the lower-limb prosthesis, resulting in an environmentally friendly and inexpensive solution.

11 February 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
VPVasja Plesec
Vasja Plesec
GHGregor Harih
Gregor Harih
The well-established finite element method (FEM) has been used successfully to evaluate and develop medical devices for lower-limb prosthetics over recent decades. Most numerical models are based on a specific 3D geometry, which, although allowing for an accurate analysis of a specific case, may differ significantly from the target group that is often geometrically closer to the average residual limb. In order to address this issue, a generic numerical transtibial model was developed with the corresponding definitive socket and silicone liner. Three load cases were performed to analyse the applicability of the model: donning, single-leg stance, and the static P5 test according to ISO 10328. While the first two cases were used commonly in previous studies, the ISO test was only used in physical tests and not in a numerical environment. The results of the simulations in terms of contact pressure, as well as the relative deformation of the socket, fit into the range reported in the literature for similar boundary conditions, thus verifying the model in biomechanical terms. The generic transtibial model serves as a numerical tool for the relative comparison of different socket-liner designs prior to the fabrication, providing insights into results that are otherwise difficult to obtain.

6 September 2024 in Biomimetics
Verified
Journal Article
Open access
PDF file
VPVasja Plesec
Vasja Plesec
GHGregor Harih
Gregor Harih
Traditional prosthetic liners are often limited in customization due to constraints in manufacturing processes and materials. Typically made from non-compressible elastomers, these liners can cause discomfort through uneven contact pressures and inadequate adaptation to the complex shape of the residual limb. This study explores the development of bioinspired cellular metamaterial prosthetic liners, designed using additive manufacturing techniques to improve comfort by reducing contact pressure and redistributing deformation at the limb–prosthesis interface. The gyroid unit cell was selected due to its favorable isotropic properties, ease of manufacturing, and ability to distribute loads efficiently. Following the initial unit cell identification analysis, the results from the uniaxial compression test on the metamaterial cellular samples were used to develop a multilinear material model, approximating the response of the metamaterial structure. Finite Element Analysis (FEA) using a previously developed generic limb–liner–socket model was employed to simulate and compare the biomechanical behavior of these novel liners against conventional silicone liners, focusing on key parameters such as peak contact pressure and liner deformation during donning, heel strike, and the push-off phase of the gait cycle. The results showed that while silicone liners provide good overall contact pressure reduction, cellular liners offer superior customization and performance optimization. The soft cellular liner significantly reduced peak contact pressure during donning compared to silicone liners but exhibited higher deformation, making it more suitable for sedentary individuals. In contrast, medium and hard cellular liners outperformed silicone liners for active individuals by reducing both contact pressure and deformation during dynamic gait phases, thereby enhancing stability. Specifically, a medium-density liner (10% infill) balanced contact pressure reduction with low deformation, offering a balance of comfort and stability. The hard cellular liner, ideal for high-impact activities, provided superior shape retention and support with lower liner deformation and comparable contact pressures to silicone liners. The results show that customizable stiffness in cellular metamaterial liners enables personalized design to address individual needs, whether focusing on comfort, stability, or both. These findings suggest that 3D-printed metamaterial liners could be a promising alternative to traditional prosthetic materials, warranting further research and clinical validation.

8 August 2025 in Biomimetics
Verified
Journal Article
Open access
PDF file
GHGregor Harih
Gregor Harih
VPVasja Plesec
Vasja Plesec
The design of ergonomic tool handles is crucial for user comfort and performance, yet conventional stiff materials often lead to uneven pressure distribution and discomfort. This study investigates the application of 3D-printed cellular metamaterials with tunable stiffness, specifically gyroid structures, to enhance the ergonomic and haptic properties of tool handles. We employed finite element analysis to simulate finger–handle interactions and conducted subjective comfort evaluations with participants using a foxtail saw with handles of varying gyroid infill densities and a rigid PLA handle. Numerical results demonstrated that handles with medium stiffness significantly reduced peak contact pressures and promoted a more uniform pressure distribution compared to the stiff PLA handle. The softest gyroid handle, while compliant, exhibited excessive deformation, potentially compromising stability. Subjective comfort ratings corroborated these findings, with medium-stiffness handles receiving the highest scores for overall comfort, fit, and force transmission. These results highlight that a plateau-like mechanical response of the 3D-printed cellular metamaterial handle, inversely bioinspired by human soft tissue, effectively balances pressure redistribution and grip stability. This bioinspired design approach offers a promising direction for developing user-centered products that mitigate fatigue and discomfort in force-intensive tasks.