The COVID-19 pandemic created the need for telerehabilitation development, while Industry 4.0 brought the key technology. As motor therapy often requires the physical support of a patient’s motion, combining robot-aided workouts with remote control is a promising solution. This may be realised with the use of the device’s digital twin, so as to give it an immersive operation. This paper presents an extensive overview of this technology’s applications within the fields of industry and health. It is followed by the in-depth analysis of needs in rehabilitation based on questionnaire research and bibliography review. As a result of these sections, the original concept of controlling a rehabilitation exoskeleton via its digital twin in the virtual reality is presented. The idea is assessed in terms of benefits and significant challenges regarding its application in real life. The presented aspects prove that it may be potentially used for manual remote kinesiotherapy, combined with the safety systems predicting potentially harmful situations. The concept is universally applicable to rehabilitation robots.
11 February 2024 in Journal of NeuroEngineering and Rehabilitation
Exoskeleton-aided active rehabilitation is a process that requires sensing and acting upon the motion intentions of the user. Typically, force sensors are used for this. However, they increase the weight and cost of these wearable devices. This paper presents the methodology for detecting users’ intentions only with encoders integrated with the drives. It is unique compared to other algorithms, as enables active kinesiotherapy while adding no sensory systems. The method is based on comparing the measured motion with the one computed with the idealised model of the multibody system. The investigation assesses the method’s performance and its robustness to model and measurement inaccuracies, as well as patients’ unintended motions. Moreover, the PID parameters are selected to provide the optimal regulation based on the dynamics requirements. The research proves the presented concept of the control approach. For all the tests with the final settings, the system reacts to a change in the user’s intention below one second and minimises the changes in proportion between the system’s acceleration and the generated user’s joint torque. The results are comparable to those obtained by EMG-based systems and significantly better than low-cost force sensors.
With pandemics, a problem of non-guaranteed constant access to rehabilitation aroused. As civilisation diseases attack a significant share of the population, providing motor treatment seems to be one of the biggest challenges towards the healthcare system of the future. While taking into account the severe level of disabilities and unexpected circumstances, the trainings may require being held in a house of a patient. Moreover, due to emergencies, a physiotherapist may not be able to participate in it personally. Thus, to mitigate the repercussions of such situations, advanced mechatronic systems for remote-home-rehabilitation have to be developed. Moreover, surveyed physiotherapists, claim that function-oriented training, robot aid, remote treatment and home therapy are the leading trends for rehabilitation of the future. Combining these is relatively difficult, as automated robotic rehabilitation requires an advanced control system. As to partially support motion along the pre-programmed trails, an optimisation problem needs to be solved. Not only to follow the trail transitionally but also to control a tilt of a gripped object and to avoid immediate large changes of velocities and accelerations if not necessary. This paper presents an approach towards an optimisation problem based on an exoskeleton of three driven and two free degrees of freedom. Simulated function-oriented training consists of diverse typical motions, such as drinking, eating, writing, steering a control wheel, lifting a bag from the ground, and lifting an object onto a shelf. Based on these, an optimisation problem is formulated. Works presented in the paper are an integral part of a planned long-term research on a home-remote-rehabilitation with a use of an exoskeleton.
31 January 2022 in Journal of Automation, Mobile Robotics and Intelligent Systems
Among past years interest in robot-assisted rehabilitation arose significantly; thus, constructions such as exoskeletons are involved in this process much more often. As a patient's bio-signals may be included in a control loop of these devices, they may be also used to support the motion of extremities in an everyday life. Therefore, a field of control over them stays a popular research topic. For this reason, an exoskeleton described in a paper was designed. The most important aim of a project was to enable all anatomical movements within ranges required for the lifting of an object while minimising the mass of the device; to enable everyday support within a wide range of motions. The following paper contains a concept of such a device with the description of a whole designing proces. It consists of antropomethric modelling, FEM simulations and topology optimisation applied to decrease the amount of material needed, and the analysis of considered manufacturing methods. As the exoskeleton was designed to be built with FDM 3-D printing technology, created parts were modelled orthotopically based on nominal mechanical parameters of filaments and directions of their beams. The design is complemented with a short description of control with EMG signals and analysis of load on a user's musculoskeletal system.
29 November 2024 in Archive of Mechanical Engineering
Exoskeletons of lower extremities are used mainly for gait treatment in physical rehabilitation. However, they are also capable of being involved in other types of exercises. Nevertheless, their structure needs to be adequately adjusted for such applications. To analyse approaches to that, this review paper investigates the mechanical designs of rehabilitation exoskeletons for lower extremities. The study seeks to identify best practices in designing and implementing these devices by analysing fifty-two articles. It covers aspects such as kinematic structures, materials used, types of drives, and the range of exercises. Standard design features include multiple degrees of freedom, primarily at the hip, knee, and ankle joints, and using lightweight materials to enhance mobility and reduce power consumption. The review also discusses the advantages of different driving systems. The findings provide valuable insights for developing effective and safe rehabilitation exoskeletons, contributing to improved patient outcomes in physiotherapy and rehabilitation settings.