Mechatronics Laboratory, Łukasiewicz Research Network – Industrial Research Institute for Automation and Measurements PIAP, Warsaw, Mazowieckie, Poland
Dr. Zbigniew Pilat
Mechatronics Laboratory, Łukasiewicz Research Network – Industrial Research Institute for Automation and Measurements PIAP, Warsaw, Mazowieckie, Poland
The COVID-19 pandemic created the need for telerehabilitation development, while Industry 4.0 brought the key technology. As motor therapy often requires the physical support of a patient’s motion, combining robot-aided workouts with remote control is a promising solution. This may be realised with the use of the device’s digital twin, so as to give it an immersive operation. This paper presents an extensive overview of this technology’s applications within the fields of industry and health. It is followed by the in-depth analysis of needs in rehabilitation based on questionnaire research and bibliography review. As a result of these sections, the original concept of controlling a rehabilitation exoskeleton via its digital twin in the virtual reality is presented. The idea is assessed in terms of benefits and significant challenges regarding its application in real life. The presented aspects prove that it may be potentially used for manual remote kinesiotherapy, combined with the safety systems predicting potentially harmful situations. The concept is universally applicable to rehabilitation robots.
Current research indicates that the education from an individualistic knowledge acquisition towards a collaborative knowledge creation culture of learning. Moreover substantive and widespread research has shown active and collaborative teaching methods increase student learning and vocational skills. Large numbers of teachers and teaching institutions (including Vocational Educational and Training - VET and academic environments) have not embraced these methods because of lack of pedagogical support from experts, administrators and colleagues when organization attempts to implement these teaching techniques. The general aim of this paper is to address those issues and present approach taken to develop an ICT based collaborative training incorporating online collaborative learning solutions to be used in the field connected with VET education (including Mechatronics education). The proposed solutions will be based on results of international research projects in a field of VET education which aim is to develop a modern approach to professional education especially related to technical knowledge.
29 November 2024 in Archive of Mechanical Engineering
Exoskeletons of lower extremities are used mainly for gait treatment in physical rehabilitation. However, they are also capable of being involved in other types of exercises. Nevertheless, their structure needs to be adequately adjusted for such applications. To analyse approaches to that, this review paper investigates the mechanical designs of rehabilitation exoskeletons for lower extremities. The study seeks to identify best practices in designing and implementing these devices by analysing fifty-two articles. It covers aspects such as kinematic structures, materials used, types of drives, and the range of exercises. Standard design features include multiple degrees of freedom, primarily at the hip, knee, and ankle joints, and using lightweight materials to enhance mobility and reduce power consumption. The review also discusses the advantages of different driving systems. The findings provide valuable insights for developing effective and safe rehabilitation exoskeletons, contributing to improved patient outcomes in physiotherapy and rehabilitation settings.
22 January 2024 in Journal of Automation, Mobile Robotics and Intelligent Systems
Contemporary international pandemic proved that a flexible approach towards work, trade and healthcare is not only favourable but a must. Hence, the devices enabling home-rehabilitation became one of the urgent needs of the medical market. The following overview is a part of an R\&D project aimed at designing an exoskeleton and developing methods enabling effective home rehabilitation. It contains a comparison of current devices in terms of their kinematics, applications, weights, sizes, and integration with selected ICT technologies. The data is analysed regarding conclusions from qualitative research, based on in-depth interviews with physiotherapists and questionnaires organised beforehand. The investigation assesses whether commercial and developed devices enable feedback from a patient by all possible means; hence, if they could allow effective telerehabilitation. Moreover, their capabilities of increasing engagement and accelerating improvements by supervising techniques and measuring biomechanical parameters are evaluated. These outcomes are a base to set the constraints and requirements before designing an exoskeleton dedicated to home treatment.
Activities in the field of increasing the productivity of the production lines for welding thick metal sheets are focused in two directions. On the one hand, new technologies are being developed for welding, deeper weld penetration and faster welding process. On the other hand are focused on automation of these operations, which have the effect of reducing cost and increasing efficiency. Improved are also the working conditions of people employed in the welding processes. In both these directions the hybrid welding Plasma-GMAW could fulfill all requirements as a new technology. The article gives the concept model of the complete robotized welding cell, in which this method will be implemented and tested.
1 September 2016 in International Journal of Advanced Robotic Systems
The use of precision actuators in robotic arm comes from the need to ensure the resulting accuracy of the robot at the maximum speed of movement. The replacement of actuators by means of electrical module allows the use of carrier body of the module for gripping flanges or other modules. Development of new modules is based on the requirement of providing a complete solution for the customer’s needs. After the development of new modules, the producer checks the parameters, receives feedback, and uses the authentication options in the independent workplaces, which can provide impartial results. Based on this data, manufacturers can optimize their solutions and deliver the products to market, complying with not only their vision but mainly the needs of customers. This article describes how to verify the characteristics of the modules used in the construction of robotic wrist. It primarily focuses on verification of the accuracy of results and repeatability of position of the wrist on output flange end module. In addition, it presents the design of the testing stand and selection methodologies of measurement. The declared values are compared with the values measured during verification.