Tomasz Osiak

Mr. Tomasz Osiak


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 January 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Piotr FalkowskiPiotr Falkowski
Piotr Falkowski
TOTomasz Osiak
Tomasz Osiak
JWJulia Małgorzata Wilk
Julia Małgorzata Wilk
NPNorbert Prokopiuk
Norbert Prokopiuk
PIAP LeczkowskiPIAP Leczkowski
PIAP Leczkowski
CRCezary Rzymkowski
Cezary Rzymkowski
The COVID-19 pandemic created the need for telerehabilitation development, while Industry 4.0 brought the key technology. As motor therapy often requires the physical support of a patient’s motion, combining robot-aided workouts with remote control is a promising solution. This may be realised with the use of the device’s digital twin, so as to give it an immersive operation. This paper presents an extensive overview of this technology’s applications within the fields of industry and health. It is followed by the in-depth analysis of needs in rehabilitation based on questionnaire research and bibliography review. As a result of these sections, the original concept of controlling a rehabilitation exoskeleton via its digital twin in the virtual reality is presented. The idea is assessed in terms of benefits and significant challenges regarding its application in real life. The presented aspects prove that it may be potentially used for manual remote kinesiotherapy, combined with the safety systems predicting potentially harmful situations. The concept is universally applicable to rehabilitation robots.

7 March 2024 in Journal of Automation, Mobile Robotics and Intelligent Systems
Verified
Journal Article
Open access
PDF file
JWJulia Małgorzata Wilk
Julia Małgorzata Wilk
Piotr FalkowskiPiotr Falkowski
Piotr Falkowski
TOTomasz Osiak
Tomasz Osiak
Home, minimally‐supervised rehabilitation has become an arising technological trend due to the shortages in medical staff. Implementing such requires providing advanced tools for automatic real‐time safety monitoring. The paper presents an approach to designing the mentioned safety system based on measurements and modelling the interface between a patient’s musculoskeletal system and a rehabilitation device. The content covers the segmentation of patients regarding their health conditions and assigns them suitable measurement techniques. The defined groups are described with the hazards, which they are most endangered, and their causes. Each case is correlated with the appropriate data type that may be used to detect potential risk. Moreover, a concept of using presented knowledge for tracking the safety of bones and soft tissues according to the biomechanical standards is included. The paper forms a set of guidelines for designing safety systems based on measurements for robot‐aided home kinesiotherapy. It can be used to select an appropriate approach regarding a specific case; so to decrease costs and increase the accuracy of the designed tools.

1 January 2024
Verified
Book Chapter
Closed access
PDF file
TOTomasz Osiak
Tomasz Osiak
NONatalia Osiak
Natalia Osiak
Piotr FalkowskiPiotr Falkowski
Piotr Falkowski
MAMehmet Emin Aktan
Mehmet Emin Aktan
PCPiotr Czerechowicz
Piotr Czerechowicz
VÖVasfi Emre Ömürlü
Vasfi Emre Ömürlü

15 March 2026 in Sensors
Verified
Journal Article
Open access
PDF file
Piotr FalkowskiPiotr Falkowski
Piotr Falkowski
PKPiotr Kołodziejski
Piotr Kołodziejski
KZKrzysztof Zawalski
Krzysztof Zawalski
MPMaciej Pikuliński
Maciej Pikuliński
JOJan Oleksiuk
Jan Oleksiuk
DŚDaniel Ireneusz Śliż
Daniel Ireneusz Śliż
Contemporary physiotherapy requires technological tools to provide effective therapy to the increasing group of patients with neurological conditions, among others. This can be achieved with rehabilitation robots, which can also be exoskeletons—wearable devices that mobilize multiple joints with complex motions representing activities of daily living. To perform kinesiotherapy conveniently in home-like environments, the exoskeletons need to be relatively lightweight. The paper presents the methodology for decreasing the mass of the exoskeleton design with real-life data-driven simulations of motions, followed by multibody dynamics simulations, and finite element method (FEM) multistep optimization. The process includes sequential initial parametric optimization, topology optimization, and final parametric optimization. The steps are used to set initial dimensional and material parameters, extract new geometrical features, and adjust the final geometry dimensions of a new design. The presented case of the SmartEx-Home exoskeleton resulted in a total mass reduction of almost 50% for the main construction elements while meeting the criteria of the minimum safety factor and maximum internal stress and strain for all components. The final design was manufactured and tested with humans, reflecting an almost fully automatic passive and active therapy.

25 September 2024
Verified
Conference Paper
Closed access
Piotr FalkowskiPiotr Falkowski
Piotr Falkowski
JOJan Oleksiuk
Jan Oleksiuk
TOTomasz Osiak
Tomasz Osiak
Rehabilitation robots support specialists physically and automate tasks. However, exercising with them requires a patient to understand the intended therapy movements. This paper explores the impact of visual interfaces on the accuracy of robot-aided physiotherapy motions. The experimental study compares three visualisation types: 2D with bar sliders, 3D with phantoms, and immersive 3D in virtual reality with phantoms. Evaluation criteria include motion accuracy, muscle loads based on the registered accelerations, and user feedback. The experiments involve trials with a passive exoskeleton setup and three visual interfaces. Participants follow the presented daily life-like movements while the sensors measure their real joint rotations. The trajectories are compared based on six dynamic-related accuracy indicators. Results show that phantom-based interfaces significantly improve motion accuracy compared to 2D, with participants favouring these methods. However, no significant superiority of the virtual reality-based method was observed. The study highlights the importance of choosing appropriate visualisations for effective robot-aided physiotherapy. The observed trends can be used to design user interfaces for exoskeletons but also end-effector rehabilitation devices.

14 August 2026 in Acta Mechanica et Automatica
Verified
Journal Article
Open access
PDF file
Piotr FalkowskiPiotr Falkowski
Piotr Falkowski
KJKajetan Jeznach
Kajetan Jeznach
TOTomasz Osiak
Tomasz Osiak
JOJan Oleksiuk
Jan Oleksiuk
KZKrzysztof Zawalski
Krzysztof Zawalski
TCTomasz Chomiuk
Tomasz Chomiuk
Population ageing, neurological and orthopaedical diseases, and shortages in medical staff result in the need to develop tools for minimally su-pervised therapy. To guarantee effective kinesiotherapy in high doses, rehabilitation robots are required. However, they require additional tech-nologies for automating treatment and monitoring patients' safety. This paper presents and assesses such technologies integrated with the SmartEx-Twin exoskeleton of a lower extremity and its digital twin in virtual reality (VR) for teleoperation during emergency cases. The intelligent algorithms were proven to increase the effectiveness of the therapy, as assessed based on the EMG measured. The VR system was validated as also increasing the effectiveness, but reducing the perception of tiring exercises, based on EEG tracking. Additionally, the accuracy of controlling exoskeleton movements was measured. It was found out that the poor operation skills of the physiotherapist in the VR environment can increase motion inaccuracies by as much as 30 degrees per joint. Additional emergency tools trig-gered by spastic cramps detected and risk of pain were assessed as fully reliable and working with the delay of up to 125 ms and 2 s, respec-tively. The whole system was implemented for the exoskeleton and will undergo further tests to minimize control inaccuracies and teleoperation delays.