Sebastiaan Eckhardt Dulfer

Mr. Sebastiaan Eckhardt Dulfer

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 January 2021 in Journal of Clinical Monitoring and Computing
Verified
Journal Article
Open access
PDF file
SDSebastiaan Eckhardt Dulfer
Sebastiaan Eckhardt Dulfer
MSM. M. Sahinovic
M. M. Sahinovic
FLF. Lange
F. Lange
FWF. H. Wapstra
F. H. Wapstra
DPD. Postmus
D. Postmus
GDG. Drost
G. Drost
For high-risk spinal surgeries, intraoperative neurophysiological monitoring (IONM) is used to detect and prevent intraoperative neurological injury. The motor tracts are monitored by recording and analyzing muscle transcranial electrical stimulation motor evoked potentials (mTc-MEPs). A mTc-MEP amplitude decrease of 50–80% is the most common warning criterion for possible neurological injury. However, these warning criteria often result in false positive warnings. False positives may be caused by inadequate depth of anesthesia and blood pressure on mTc-MEP amplitudes. The aim of this paper is to validate the study protocol in which the goal is to investigate the effects of depth of anesthesia (part 1) and blood pressure (part 2) on mTc-MEPs. Per part, 25 patients will be included. In order to investigate the effects of depth of anesthesia, a processed electroencephalogram (pEEG) monitor will be used. At pEEG values of 30, 40 and 50, mTc-MEP measurements will be performed. To examine the effect of blood pressure on mTc-MEPs the mean arterial pressure will be elevated from 60 to 100 mmHg during which mTc-MEP measurements will be performed. We hypothesize that by understanding the effects of depth of anesthesia and blood pressure on mTc-MEPs, the mTc-MEP monitoring can be interpreted more reliably. This may contribute to fewer false positive warnings. By performing this study after induction and prior to incision, this protocol provides a unique opportunity to study the effects of depths of anesthesia and blood pressure on mTc-MEPs alone with as little confounders as possible.Trial registration numberNL7772.

10 February 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MGMarieke Gadella
Marieke Gadella
SDSebastiaan Eckhardt Dulfer
Sebastiaan Eckhardt Dulfer
AAAnthony R. Absalom
Anthony R. Absalom
FLFiete Lange
Fiete Lange
CSCarola H. M. Scholtens-Henzen
Carola H. M. Scholtens-Henzen
Gea DrostGea Drost
Gea Drost
Muscle-recorded transcranial electrical stimulation motor-evoked potentials (mTc-MEPs) are used to assess the spinal cord integrity. They are commonly recorded with subcutaneous needle or surface electrodes, but the different characteristics of mTc-MEP signals recorded with the two types of electrodes have not been formally compared yet. In this study, mTc-MEPs were simultaneously recorded from the tibialis anterior (TA) muscles using surface and subcutaneous needle electrodes in 242 consecutive patients. Elicitability, motor thresholds, amplitude, area under the curve (AUC), signal-to-noise ratio (SNR), and the variability between mTc-MEP amplitudes were compared. Whereas amplitude and AUC were significantly higher in subcutaneous needle recordings (p < 0.01), motor thresholds and elicitability were similar for surface and subcutaneous needle recordings. Moreover, the SNRs were >2 in more than 99.5% of the surface and subcutaneous needle recordings, and the variability between consecutive amplitudes was not significantly different between the two recording electrode types (p = 0.34). Surface electrodes appear to be a good alternative to needle electrodes for spinal cord monitoring. They are non-invasive, can record signals at similar threshold intensities, have adequately high SNRs, and record signals with equivalent variability. Whether surface electrodes are non-inferior to subcutaneous needle electrodes in detecting motor warnings is investigated in part II of the NERFACE study.

21 May 2020 in European Spine Journal
Verified
Journal Article
Open access
PDF file
SDSebastiaan Eckhardt Dulfer
Sebastiaan Eckhardt Dulfer
FLF. Lange
F. Lange
FWF. H. Wapstra
F. H. Wapstra
APA. R. E. Potgieser
A. R. E. Potgieser
JVJ. P. Valk
J. P. Valk
GDG. Drost
G. Drost
Purpose: Little is known about the reliability and value of intraoperative neurophysiological monitoring (IONM) in patients with Duchenne muscular dystrophy (DMD) undergoing scoliosis correction surgery. The aim of this study was to investigate the feasibility of IONM and the cortical excitability in these patients. Methods: Fifteen patients with DMD and scoliosis and 15 patients with adolescent idiopathic scoliosis (AIS) underwent scoliosis correction surgery with the use of IONM. IONM consisted of transcranial electrical stimulation motor evoked potential (Tc-MEP) and somatosensory evoked potential (SSEP) monitoring. The highest Tc-MEP amplitudes were collected to test the feasibility. Preoperative compound muscle action potentials (CMAPs) and transcranial magnetic stimulation (TMS)-MEPs were recorded to test the cortical excitability. SSEPs were scored as elicitable or not elicitable. Results: Tc-MEP amplitudes were significantly lower in the DMD group for both the gastrocnemius and tibialis anterior muscles. However, the abductor hallucis muscle had similar amplitudes in both the DMD as the AIS group. TMS/CMAP and Tc-MEP/CMAP ratios were similar in the DMD and AIS group (P = 0.126 and P = 0.792 respectively). Conclusions: Tc-MEP and SSEP monitoring is feasible, particularly when Tc-MEPs are recorded from the abductor hallucis muscle in patients with DMD. Similar TMS/CMAP and Tc-MEP/CMAP ratios show that there were no differences observed in cortical excitability between the groups. IONM seems a feasible and valuable neurophysiological tool to signal possible surgically induced damage to the spinal cord during scoliosis correction surgery in patients with DMD.

22 February 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
SDSebastiaan Eckhardt Dulfer
Sebastiaan Eckhardt Dulfer
MGMarieke Gadella
Marieke Gadella
KTKatalin Tamasi
Katalin Tamasi
AAAnthony R. Absalom
Anthony R. Absalom
FLFiete Lange
Fiete Lange
Gea DrostGea Drost
Gea Drost
In the NERFACE study part I, the characteristics of muscle transcranial electrical stimulation motor evoked potentials (mTc-MEPs) recorded from the tibialis anterior (TA) muscles with surface and subcutaneous needle electrodes were compared. The aim of this study (NERFACE part II) was to investigate whether the use of surface electrodes was non-inferior to the use of subcutaneous needle electrodes in detecting mTc-MEP warnings during spinal cord monitoring. mTc-MEPs were simultaneously recorded from TA muscles with surface and subcutaneous needle electrodes. Monitoring outcomes (no warning, reversible warning, irreversible warning, complete loss of mTc-MEP amplitude) and neurological outcomes (no, transient, or permanent new motor deficits) were collected. The non-inferiority margin was 5%. In total, 210 (86.8%) out of 242 consecutive patients were included. There was a perfect agreement between both recording electrode types for the detection of mTc-MEP warnings. For both electrode types, the proportion of patients with a warning was 0.12 (25/210) (difference, 0.0% (one-sided 95% CI, 0.014)), indicating non-inferiority of the surface electrode. Moreover, reversible warnings for both electrode types were never followed by permanent new motor deficits, whereas among the 10 patients with irreversible warnings or complete loss of amplitude, more than half developed transient or permanent new motor deficits. In conclusion, the use of surface electrodes was non-inferior to the use of subcutaneous needle electrodes for the detection of mTc-MEP warnings recorded over the TA muscles.

28 December 2023 in Anesthesia & Analgesia
Verified
Journal Article
Open access
SDSebastiaan Eckhardt Dulfer
Sebastiaan Eckhardt Dulfer
HGHenk Groen
Henk Groen
RGRobertus J. M. Groen
Robertus J. M. Groen
AAAnthony R. Absalom
Anthony R. Absalom
MSMarko M. Sahinovic
Marko M. Sahinovic
GDGea Drost
Gea Drost
BACKGROUND: During spinal surgery, the motor tracts can be monitored using muscle-recorded transcranial electrical stimulation motor-evoked potentials (mTc-MEPs). We aimed to investigate the association of anesthetic and physiological parameters with mTc-MEPs. METHODS: Intraoperative mTc-MEP amplitudes, mTc-MEP area under the curves (AUC), and anesthetic and physiological measurements were collected retrospectively from the records of 108 consecutive patients undergoing elective spinal surgery. Pharmacological parameters of interest included propofol and opioid concentration, ketamine and noradrenaline infusion rates. Physiological parameters recorded included mean arterial pressure (MAP), bispectral index (BIS), heart rate, hemoglobin O 2 saturation, temperature, and Et co 2 . A forward selection procedure was performed using multivariable mixed model analysis. RESULTS: Data from 75 (69.4%) patients were included. MAP and BIS were significantly associated with mTc-MEP amplitude ( P < .001). mTc-MEP amplitudes increased by 6.6% (95% confidence interval [CI], 2.7%–10.4%) per 10 mm Hg increase in MAP and by 2.79% (CI, 2.26%–3.32%) for every unit increase in BIS. MAP ( P < .001), BIS ( P < .001), heart rate ( P = .01), and temperature ( P = .02) were significantly associated with mTc-MEP AUC. The AUC increased by 7.5% (CI, 3.3%–11.7%) per 10 mm Hg increase of MAP, by 2.98% (CI, 2.41%–3.54%) per unit increase in BIS, and by 0.68% (CI, 0.13%–1.23%) per beat per minute increase in heart rate. mTc-MEP AUC decreased by 21.4% (CI, −38.11% to −3.98%) per degree increase in temperature. CONCLUSIONS: MAP, BIS, heart rate, and temperature were significantly associated with mTc-MEP amplitude and/or AUC. Maintenance of BIS and MAP at the high normal values may attenuate anesthetic effects on mTc-MEPs.

3 March 2023 in Clinical Neurophysiology
Verified
Journal Article
Open access
SDSebastiaan Eckhardt Dulfer
Sebastiaan Eckhardt Dulfer
MGM.C. Gadella
M.C. Gadella
MSM.M. Sahinovic
M.M. Sahinovic
FLFiete Lange
Fiete Lange
AAA.R. Absalom
A.R. Absalom
GDG. Drost
G. Drost
The aim of this systematic review was to find the optimal stimulation parameters for muscle recorded transcranial electrical stimulation motor evoked potential (mTc-MEP) and D-wave monitoring during spinal cord monitoring. A PRISMA systematic search in Medline and EMBASE and a QUADAS-2 quality evaluation was performed to identify studies that compared stimulation parameters consisting of stimulation location, number of pulses, pulse duration, interstimulus interval, double train (DTS) or recurrent train stimulation (RTS) and intertrain interval (ITI) for performing mTc-MEP and D-wave monitoring. Only studies that used total intravenous anaesthesia (TIVA) were included. Ten studies that compared stimulation parameters for performing mTc-MEP monitoring (stimulation location n = 4, number of pulses n = 2, pulse duration n = 1, interstimulus interval n = 4, DTS n = 1, RTS n = 2, ITI n = 2) were included. No studies compared stimulation parameters (stimulation location and pulse duration) for performing D-wave monitoring. Few studies examined the optimal stimulation parameters for monitoring mTc-MEPs and no studies were included for D-wave monitoring. There is a need for prospective research to investigate the optimal stimulation parameters for mTc-MEP with the use of TIVA and D-wave monitoring. For mTc-MEP monitoring, a table is provided in which the recommended stimulation parameters are stated.