Marieke Gadella

Ms. Marieke Gadella

Anesthesiology and Neurosurgery, University Medical Center Groningen, Groningen, The Netherlands
orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 February 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MGMarieke Gadella
Marieke Gadella
SDSebastiaan Eckhardt Dulfer
Sebastiaan Eckhardt Dulfer
AAAnthony R. Absalom
Anthony R. Absalom
FLFiete Lange
Fiete Lange
CSCarola H. M. Scholtens-Henzen
Carola H. M. Scholtens-Henzen
Gea DrostGea Drost
Gea Drost
Muscle-recorded transcranial electrical stimulation motor-evoked potentials (mTc-MEPs) are used to assess the spinal cord integrity. They are commonly recorded with subcutaneous needle or surface electrodes, but the different characteristics of mTc-MEP signals recorded with the two types of electrodes have not been formally compared yet. In this study, mTc-MEPs were simultaneously recorded from the tibialis anterior (TA) muscles using surface and subcutaneous needle electrodes in 242 consecutive patients. Elicitability, motor thresholds, amplitude, area under the curve (AUC), signal-to-noise ratio (SNR), and the variability between mTc-MEP amplitudes were compared. Whereas amplitude and AUC were significantly higher in subcutaneous needle recordings (p < 0.01), motor thresholds and elicitability were similar for surface and subcutaneous needle recordings. Moreover, the SNRs were >2 in more than 99.5% of the surface and subcutaneous needle recordings, and the variability between consecutive amplitudes was not significantly different between the two recording electrode types (p = 0.34). Surface electrodes appear to be a good alternative to needle electrodes for spinal cord monitoring. They are non-invasive, can record signals at similar threshold intensities, have adequately high SNRs, and record signals with equivalent variability. Whether surface electrodes are non-inferior to subcutaneous needle electrodes in detecting motor warnings is investigated in part II of the NERFACE study.

22 February 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
SDSebastiaan Eckhardt Dulfer
Sebastiaan Eckhardt Dulfer
MGMarieke Gadella
Marieke Gadella
KTKatalin Tamasi
Katalin Tamasi
AAAnthony R. Absalom
Anthony R. Absalom
FLFiete Lange
Fiete Lange
Gea DrostGea Drost
Gea Drost
In the NERFACE study part I, the characteristics of muscle transcranial electrical stimulation motor evoked potentials (mTc-MEPs) recorded from the tibialis anterior (TA) muscles with surface and subcutaneous needle electrodes were compared. The aim of this study (NERFACE part II) was to investigate whether the use of surface electrodes was non-inferior to the use of subcutaneous needle electrodes in detecting mTc-MEP warnings during spinal cord monitoring. mTc-MEPs were simultaneously recorded from TA muscles with surface and subcutaneous needle electrodes. Monitoring outcomes (no warning, reversible warning, irreversible warning, complete loss of mTc-MEP amplitude) and neurological outcomes (no, transient, or permanent new motor deficits) were collected. The non-inferiority margin was 5%. In total, 210 (86.8%) out of 242 consecutive patients were included. There was a perfect agreement between both recording electrode types for the detection of mTc-MEP warnings. For both electrode types, the proportion of patients with a warning was 0.12 (25/210) (difference, 0.0% (one-sided 95% CI, 0.014)), indicating non-inferiority of the surface electrode. Moreover, reversible warnings for both electrode types were never followed by permanent new motor deficits, whereas among the 10 patients with irreversible warnings or complete loss of amplitude, more than half developed transient or permanent new motor deficits. In conclusion, the use of surface electrodes was non-inferior to the use of subcutaneous needle electrodes for the detection of mTc-MEP warnings recorded over the TA muscles.

15 May 2023 in Clinical Neurophysiology
Verified
Journal Article
Closed access
SDSebastiaan Eckhardt Dulfer
Sebastiaan Eckhardt Dulfer
MGMarieke Gadella
Marieke Gadella
MSM.M. Sahinovic
M.M. Sahinovic
FLFiete Lange
Fiete Lange
AAA.R. Absalom
A.R. Absalom
GDG. Drost
G. Drost

4 March 2026 in Clinical Neurophysiology
Verified
Journal Article
Open access
MGMarieke Gadella
Marieke Gadella
MSM. Sahinovic
M. Sahinovic
CSC.H.M. Scholtens-Henzen
C.H.M. Scholtens-Henzen
ADA. Dunker-Talen
A. Dunker-Talen
FLFiete Lange
Fiete Lange
Gea DrostGea Drost
Gea Drost
Late motor responses, such as F-waves and H-reflexes, may reflect excitability of specific spinal cord segments and motor pathway integrity, offering potential value during intraoperative neurophysiological monitoring (IONM). However, these responses are not routinely utilized. A better understanding of the effect of general anaesthesia on their characteristics, particularly across varying depths, is essential for integration into IONM. Participants received propofol/remifentanil-based anaesthesia, targeted at BIS values of 30, 40, and 50. F-waves, H-reflexes and Tc-mMEPs were recorded every 2-4 min. Anaesthetic effect was evaluated using linear mixed-effects models. 23 of 25 patients exhibited consistent H-reflexes. F-waves were elicitable in all patients, though muscle-dependant variability was observed. H-reflex amplitude decreased by 10% per 10-point BIS increase (p = 0.014), while F-wave amplitude increased by 6-9% per 10 points BIS increase in abductor hallucis and hand muscles (p < 0.01), with no significant changes in the tibialis anterior and gastrocnemius muscles. F-wave persistence varied < 5% per 10 BIS-points. Late responses can be reliably recorded during propofol/remifentanil anaesthesia. F-waves exhibit greater variability than H-reflexes, potentially limiting their utility in certain muscle groups. They were modestly influenced by deeper anaesthesia but were still elicitable and interpretable. Changing depth of anaesthesia has differential effects on late responses of different muscles.

28 October 2026 in Anesthesia & Analgesia
Verified
Journal Article
Closed access
MGMarieke Gadella
Marieke Gadella
RLRoald A. Lambrechts
Roald A. Lambrechts
MSMarko M. Sahinovic
Marko M. Sahinovic
RGRob J.M. Groen
Rob J.M. Groen
AAAnthony R. Absalom
Anthony R. Absalom
Gea DrostGea Drost
Gea Drost
Late motor responses, including F-waves and H-reflexes, are commonly recorded during electrophysiological diagnostic evaluation in awake patients. Although these responses could offer added value during intraoperative neurophysiological monitoring, their use has not yet been widely adopted. This systematic review aims to assess current knowledge on how anesthetic and surgical factors influence the recording and monitoring of spinal late responses during surgery. The authors searched PubMed and EMBASE for relevant articles on studies of late response recording. Studies were considered eligible if the influence of one or more of the following parameters on late responses were assessed: (1) ventilation and metabolic parameters, (2) volatile agents, (3) intravenous agents, (4) neuromuscular blocking agents, (5) epidural or intrathecal agents, or (6) surgical factors. The QUADAS-2 tool was used to assess the risk of bias and concerns regarding applicability. Sixty-two studies were included. Respiratory conditions like hypercapnia reduced H-reflex amplitude, whereas hyperoxia and intermittent hypoxia had limited impact. Volatile agents, including isoflurane, sevoflurane, and nitrous oxide decreased late response amplitudes, with dose-dependent effects. Most intravenous anesthetics, particularly propofol, reduced H-reflex amplitude and F-wave persistence in a dose-dependent manner. Conversely, ketamine was found to increase H-reflex amplitude. During spinal and vascular surgeries, H-reflex monitoring proved feasible and provided valuable supplementary data to the conventional motor evoked potential (MEP) and somatosensory evoked potential (SSEP) modalities. This systematic review demonstrates that H-reflexes and F-waves are significantly influenced by anesthetic factors. The reviewed studies indicate that intravenous and volatile anesthetics significantly affect late responses, by reducing H-reflex and F-wave amplitudes, whereas latencies appear unaffected. The methodological quality varied significantly across the included studies and affects the interpretation of their conclusions. These findings support the potential integration of late response monitoring into intraoperative neurophysiological monitoring (IONM) protocols, provided that anesthetic management and surgical context are carefully considered.