Muscle-recorded transcranial electrical stimulation motor-evoked potentials (mTc-MEPs) are used to assess the spinal cord integrity. They are commonly recorded with subcutaneous needle or surface electrodes, but the different characteristics of mTc-MEP signals recorded with the two types of electrodes have not been formally compared yet. In this study, mTc-MEPs were simultaneously recorded from the tibialis anterior (TA) muscles using surface and subcutaneous needle electrodes in 242 consecutive patients. Elicitability, motor thresholds, amplitude, area under the curve (AUC), signal-to-noise ratio (SNR), and the variability between mTc-MEP amplitudes were compared. Whereas amplitude and AUC were significantly higher in subcutaneous needle recordings (p < 0.01), motor thresholds and elicitability were similar for surface and subcutaneous needle recordings. Moreover, the SNRs were >2 in more than 99.5% of the surface and subcutaneous needle recordings, and the variability between consecutive amplitudes was not significantly different between the two recording electrode types (p = 0.34). Surface electrodes appear to be a good alternative to needle electrodes for spinal cord monitoring. They are non-invasive, can record signals at similar threshold intensities, have adequately high SNRs, and record signals with equivalent variability. Whether surface electrodes are non-inferior to subcutaneous needle electrodes in detecting motor warnings is investigated in part II of the NERFACE study.
In the NERFACE study part I, the characteristics of muscle transcranial electrical stimulation motor evoked potentials (mTc-MEPs) recorded from the tibialis anterior (TA) muscles with surface and subcutaneous needle electrodes were compared. The aim of this study (NERFACE part II) was to investigate whether the use of surface electrodes was non-inferior to the use of subcutaneous needle electrodes in detecting mTc-MEP warnings during spinal cord monitoring. mTc-MEPs were simultaneously recorded from TA muscles with surface and subcutaneous needle electrodes. Monitoring outcomes (no warning, reversible warning, irreversible warning, complete loss of mTc-MEP amplitude) and neurological outcomes (no, transient, or permanent new motor deficits) were collected. The non-inferiority margin was 5%. In total, 210 (86.8%) out of 242 consecutive patients were included. There was a perfect agreement between both recording electrode types for the detection of mTc-MEP warnings. For both electrode types, the proportion of patients with a warning was 0.12 (25/210) (difference, 0.0% (one-sided 95% CI, 0.014)), indicating non-inferiority of the surface electrode. Moreover, reversible warnings for both electrode types were never followed by permanent new motor deficits, whereas among the 10 patients with irreversible warnings or complete loss of amplitude, more than half developed transient or permanent new motor deficits. In conclusion, the use of surface electrodes was non-inferior to the use of subcutaneous needle electrodes for the detection of mTc-MEP warnings recorded over the TA muscles.
The aim of this systematic review was to find the optimal stimulation parameters for muscle recorded transcranial electrical stimulation motor evoked potential (mTc-MEP) and D-wave monitoring during spinal cord monitoring. A PRISMA systematic search in Medline and EMBASE and a QUADAS-2 quality evaluation was performed to identify studies that compared stimulation parameters consisting of stimulation location, number of pulses, pulse duration, interstimulus interval, double train (DTS) or recurrent train stimulation (RTS) and intertrain interval (ITI) for performing mTc-MEP and D-wave monitoring. Only studies that used total intravenous anaesthesia (TIVA) were included. Ten studies that compared stimulation parameters for performing mTc-MEP monitoring (stimulation location n = 4, number of pulses n = 2, pulse duration n = 1, interstimulus interval n = 4, DTS n = 1, RTS n = 2, ITI n = 2) were included. No studies compared stimulation parameters (stimulation location and pulse duration) for performing D-wave monitoring. Few studies examined the optimal stimulation parameters for monitoring mTc-MEPs and no studies were included for D-wave monitoring. There is a need for prospective research to investigate the optimal stimulation parameters for mTc-MEP with the use of TIVA and D-wave monitoring. For mTc-MEP monitoring, a table is provided in which the recommended stimulation parameters are stated.
26 October 2022 in Clinical Parkinsonism & Related Disorders
Vertical supranuclear gaze palsy is a key feature of Niemann-Pick type C (NP-C) and is commonly quantified using video-oculography (VOG). VOG requires sitting still for long times and performing specific tasks, thus it can be challenging or impossible for patients severely affected by movement disorders or cognitive impairment. To overcome this limitation, we measure saccades of NP-C patients using a fast eye tracking test based on continuous psychophysics and compare it to VOG. Saccades of six NP-C patients and six age-matched controls were assessed using VOG and Standardized Oculomotor and Neuro-ophthalmic Disorders Assessment (SONDA). In SONDA, participants continuously track a semi-randomly moving dot on a computer screen while their gaze is being tracked. For both assessments, saccades were quantified using four conventional measures: amplitude, gain, latency, and peak velocity. Furthermore, SONDA’s continuous measures were quantified with several novel spatio-temporal properties. In the NP-C patients, both methods revealed reduced amplitude, gain, peak velocity, and increased latency of vertical saccades compared to horizontal saccades and compared to healthy controls. Effect sizes obtained with SONDA were overall larger than those for VOG. SONDA’s spatio-temporal properties showed similar trends. SONDA reveals a deterioration of vertical saccades in NP-C patients that is consistent with VOG. SONDA’s measures based on continuous psychophysics are consistent with traditional saccadic parameters and can potentially provide complementary information. SONDA shows larger effect sizes than VOG, suggesting that it provides robust and clinically relevant outcomes with a more intuitive task and shorter testing time.
Late motor responses, such as F-waves and H-reflexes, may reflect excitability of specific spinal cord segments and motor pathway integrity, offering potential value during intraoperative neurophysiological monitoring (IONM). However, these responses are not routinely utilized. A better understanding of the effect of general anaesthesia on their characteristics, particularly across varying depths, is essential for integration into IONM. Participants received propofol/remifentanil-based anaesthesia, targeted at BIS values of 30, 40, and 50. F-waves, H-reflexes and Tc-mMEPs were recorded every 2-4 min. Anaesthetic effect was evaluated using linear mixed-effects models. 23 of 25 patients exhibited consistent H-reflexes. F-waves were elicitable in all patients, though muscle-dependant variability was observed. H-reflex amplitude decreased by 10% per 10-point BIS increase (p = 0.014), while F-wave amplitude increased by 6-9% per 10 points BIS increase in abductor hallucis and hand muscles (p < 0.01), with no significant changes in the tibialis anterior and gastrocnemius muscles. F-wave persistence varied < 5% per 10 BIS-points. Late responses can be reliably recorded during propofol/remifentanil anaesthesia. F-waves exhibit greater variability than H-reflexes, potentially limiting their utility in certain muscle groups. They were modestly influenced by deeper anaesthesia but were still elicitable and interpretable. Changing depth of anaesthesia has differential effects on late responses of different muscles.