Srđan M Bošnjak

Prof. Dr. Srđan M Bošnjak


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2015 in Engineering Failure Analysis
Verified
Journal Article
Closed access
Srđan M BošnjakSrđan M Bošnjak
Srđan M Bošnjak
SSSreten D. Savićević
Sreten D. Savićević
NGNebojša B. Gnjatović
Nebojša B. Gnjatović
IMIvan L.J. Milenović
Ivan L.J. Milenović
MPMilorad P. Pantelić
Milorad P. Pantelić

20 March 2016 in Eksploatacja i Niezawodność – Maintenance and Reliability
Verified
Journal Article
Closed access
Srđan M BošnjakSrđan M Bošnjak
Srđan M Bošnjak
MAMiodrag Arsić
Miodrag Arsić
SSSreten Savićević
Sreten Savićević
GMGoran Milojević
Goran Milojević
Dušan ArsićDušan Arsić
Dušan Arsić

18 May 2016 in Journal of Zhejiang University-SCIENCE A
Verified
Journal Article
Closed access
PDF file
Srđan M BošnjakSrđan M Bošnjak
Srđan M Bošnjak
NGNebojša B. Gnjatović
Nebojša B. Gnjatović
SSSreten D. Savićević
Sreten D. Savićević
MPMilorad P. Pantelić
Milorad P. Pantelić
IMIvan Lj. Milenović
Ivan Lj. Milenović
Determining a bucket wheel excavator (BWE)’s slewing superstructure weight and its center of gravity (COG) is of extreme importance not only in the d

1 April 2015 in Case Studies in Engineering Failure Analysis
Verified
Journal Article
Open access
Srđan M BošnjakSrđan M Bošnjak
Srđan M Bošnjak
NGNebojša B. Gnjatović
Nebojša B. Gnjatović
DMDejan B. Momčilović
Dejan B. Momčilović
IMIvan L.J. Milenović
Ivan L.J. Milenović
VGVlada M. Gašić
Vlada M. Gašić
This paper presents an investigation of the accident which occurred during startup of the extending structure from the transport position. In order to clarify the causes of crack occurrence along almost the entire surface of the lever cross-section, the authors performed visual, experimental (chemical composition, tensile properties, microhardness) as well as metallographic examinations. Stress states in the critical zone are defined by applying the finite element method (FEM). Based on the investigation results it was concluded that the lever breakdown is predominantly caused by both the ‘operating-in’ defect (the malfunction of the limit switch) and the ‘manufacturing-in’ defect (poor weld quality). The investigation results presented in this paper are important because same or similar problems could arise in supporting structures of various types of transportation, construction and mining machines

20 March 2018 in Eksploatacja i Niezawodność – Maintenance and Reliability
Verified
Journal Article
Closed access
Srđan M BošnjakSrđan M Bošnjak
Srđan M Bošnjak
Nebojsa GnjatovicNebojsa Gnjatovic
Nebojsa Gnjatovic
IMIvan Milenović
Ivan Milenović

28 December 2022 in Mathematics
Verified
Journal Article
Open access
PDF file
Nebojsa GnjatovicNebojsa Gnjatovic
Nebojsa Gnjatovic
Srđan M BošnjakSrđan M Bošnjak
Srđan M Bošnjak
ASAleksandar Stefanović
Aleksandar Stefanović
Continuous earthmoving machines, such as bucket-wheel excavators (BWEs), are the largest mobile terrestrial machines exposed to the working loads of a periodic character. This paper aims to launch a new idea regarding the preservation of the load-carrying structures of these machines by the means of implementing a controllable frequency-controlled drive of the excavating device. Successful implementation of this idea requires a detailed analysis of the dynamic response of the load-carrying structure in order to determine the domains of frequency of revolutions of the bucket-wheel-drive electromotor (FREM) where the dynamic response of the structure is favorable. The main goal of the presented research was the development of a unique three-step method for the identification of the FREM ranges, where the vibroactivity of the load-carrying structure is within the allowed boundaries. A methodologically original study of the dynamic response was conducted on a unique dynamic model of the BWE slewing superstructure that allows for continuous variation of the FREM, i.e., of the frequency of excitation caused by the forces resisting the excavation. Validation of the spatial reduced dynamic model of the slewing superstructure and the corresponding mathematical model, as well as the overall approach to the determination of the dynamic response, were performed by the means of vibrodiagnostics under the real exploitation conditions. Application of the developed method has yielded: (1) the resonant-free FREM domains; (2) the FREM domains, where the structure is not exposed to the excessive dynamic impacts; and (3) the frequency ratio ranges defining the resonant areas. Additionally, the results of the research have pointed out that the resonant-free state represents a necessary but insufficient condition for the proper dynamic behavior of the BWE slewing superstructure.