1 April 2015 in Case Studies in Engineering Failure Analysis
This paper presents an investigation of the accident which occurred during startup of the extending structure from the transport position. In order to clarify the causes of crack occurrence along almost the entire surface of the lever cross-section, the authors performed visual, experimental (chemical composition, tensile properties, microhardness) as well as metallographic examinations. Stress states in the critical zone are defined by applying the finite element method (FEM). Based on the investigation results it was concluded that the lever breakdown is predominantly caused by both the ‘operating-in’ defect (the malfunction of the limit switch) and the ‘manufacturing-in’ defect (poor weld quality). The investigation results presented in this paper are important because same or similar problems could arise in supporting structures of various types of transportation, construction and mining machines
11 January 2013 in Advanced Materials Research
Energy efficiency is a key issue worldwide, and not confined solely to the realm of engineers. Past failures of mechanical power system components must be examined carefully in order to minimise future occurrences and increase energy efficiencies. Improved design procedures have been highly sought by engineers and researchers over the past few decades. The latest verified method with strong application potential within the power industry is that of the Theory of Critical Distances (TCD). TCD is not one method, but a group of methods that have a common feature; the use of a characteristic material length parameter, the critical distance L, for calculating the influence of notch-like stress raisers under static and fatigue loading. A case study from a hydro power plant turbine shaft was chosen to illustrate the development of this methodology. The paper illustrates the application of TCD to the fatigue life assessment of a turbine shaft with stress concentrations due to pitting corrosion.
1 January 2026 in Tehnika
BSBratislav N. Stojiljković
Bratislav N. Stojiljković
Among the numerous artifacts in the scientist's legacy in the Nikola Tesla Museum in Belgrade there are sketches of original conceptual solutions, technical drawings, patent documentation, several sheets of handwritten calculations related to the design of a new fountain model (engine characteristics, fluid flow parameters, dimensions of structural elements), as well as other archival material that testifies to his work on this invention. This research aims to analyze the preserved technical and other archival documents related to the development of several different conceptual solutions of the fountain model for which Tesla, in cooperation with his lawyers, prepared and submitted an application to the Patent Office of the United States of America at the end of October 1913 and for which he was granted US patent No. 1,113,716. We reviewed all the modifications to the construction of the imagined models of the new fountain, which were carried out during the entire development process, from the initial idea to the final patented solutions. To that end, we also made computer models based on original technical and patent documentation.
1 January 2025 in FME Transactions
ASAleksandar Z. Stefanović
This paper presents the results of the holistic failure-based root cause analysis of a sudden collapse of the inclined belt conveyor bridge (IBCB), which is a vital subsystem of a steel mill raw material handling system. Through a comprehensive analysis of the set of possible causes ('design-in' defects, 'manufacturing-in' defects, 'exploitation-in' defects and 'environmental-in' defects), by the method of elimination it has been determined that the inadequate maintenance of the anti-corrosion coating was the root cause of collapse of the IBCB. Due to inadequate maintenance of the anti-corrosion coating of the IBCB structure, heavy and uniform corrosion, provoked by increased acidity of precipitations in the area of the steel mill, had led to disintegration of structural elements and, ultimately, collapse of the IBCB structure. Additionally, based on the appearance and position of the collapsed remains of the IBCB, as well as state of the objects connected by it before the breakdown, the structural collapse scenario was established. Results of the presented investigation underline the importance of the corrosion inspection and monitoring, especially in cases of facilities exposed to chemically aggressive environments. The expenses of planned standstills for the purpose of corrosion inspection and potential repairs on the structural elements damaged by corrosion are significantly lower than direct and indirect expenses of by accidental destruction.