Serhat Ilbey

Mr. Serhat Ilbey

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 September 2022 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
XSXin Shen
Xin Shen
AÖAli Caglar Özen
Ali Caglar Özen
ASAntonia Sunjar
Antonia Sunjar
SISerhat Ilbey
Serhat Ilbey
SSStephen Sawiak
Stephen Sawiak
Uzay EmirUzay Emir
Uzay Emir
Purpose: This study aimed to develop a new 3D dual‐echo rosette k‐space trajectory, specifically designed for UTE MRI applications. The imaging of the ultra‐short transverse relaxation time (uT2) of brain was acquired to test the performance of the proposed UTE sequence.Theory and Methods: The rosette trajectory was developed based on rotations of a “petal‐like” pattern in the kx–ky plane, with oscillated extensions in the kz‐direction for 3D coverage. Five healthy volunteers underwent 10 dual‐echo 3D rosette UTE scans with various TEs. Dual‐exponential complex model fitting was performed on the magnitude data to separate uT2 signals, with the output of uT2 fraction, uT2 value, and long‐T2 value.Results: The 3D rosette dual‐echo UTE sequence showed better performance than a 3D radial UTE acquisition. More significant signal intensity decay in white matter than gray matter was observed along with the TEs. The white matter regions had higher uT2 fraction values than gray matter (10.9% ± 1.9% vs. 5.7% ± 2.4%). The uT2 value was approximately 0.10 ms in white matter .Conclusion: The higher uT2 fraction value in white matter compared to gray matter demonstrated the ability of the proposed sequence to capture rapidly decaying signals.

29 January 2019 in Medical Physics
Verified
Journal Article
Closed access
PDF file
CTCan Barış Top
Can Barış Top
AGAlper Güngör
Alper Güngör
SISerhat Ilbey
Serhat Ilbey
HGH. Emre Güven
H. Emre Güven

28 October 2017 in Medical Physics
Verified
Journal Article
Closed access
PDF file
CTCan Barış Top
Can Barış Top
SISerhat Ilbey
Serhat Ilbey
HGHüseyin Emre Güven
Hüseyin Emre Güven

12 January 2023 in Nanomaterials
Verified
Journal Article
Open access
PDF file
HVHamidreza Saeidi Varnamkhasti
Hamidreza Saeidi Varnamkhasti
MMMorteza Mozaffari
Morteza Mozaffari
SISerhat Ilbey
Serhat Ilbey
SDSilvio Dutz
Silvio Dutz
DZDiana Zahn
Diana Zahn
MBMichael Bock
Michael Bock
Magnetic nanoparticles (MNPs) have been widely applied as magnetic resonance imaging (MRI) contrast agents. MNPs offer significant contrast improvements in MRI through their tunable relaxivities, but to apply them as clinical contrast agents effectively, they should exhibit a high saturation magnetization, good colloidal stability and sufficient biocompatibility. In this work, we present a detailed description of the synthesis and the characterizations of europium-substituted Mn–Zn ferrite (Mn0.6Zn0.4EuxFe2−xO4, x = 0.00, 0.02, 0.04, 0.06, 0.08, 0.10, and 0.15, herein named MZF for x = 0.00 and EuMZF for others). MNPs were synthesized by the coprecipitation method and subsequent hydrothermal treatment, coated with citric acid (CA) or pluronic F127 (PF-127) and finally characterized by X-ray Diffraction (XRD), Inductively Coupled Plasma (ICP), Vibrating Sample Magnetometry (VSM), Fourier-Transform Infrared (FTIR), Dynamic Light Scattering (DLS) and MRI Relaxometry at 3T methods. The XRD studies revealed that all main diffraction peaks are matched with the spinel structure very well, so they are nearly single phase. Furthermore, XRD study showed that, although there are no significant changes in lattice constants, crystallite sizes are affected by europium substitution significantly. Room-temperature magnetometry showed that, in addition to coercivity, both saturation and remnant magnetizations decrease with increasing europium substitution and coating with pluronic F127. FTIR study confirmed the presence of citric acid and poloxamer (pluronic F127) coatings on the surface of the nanoparticles. Relaxometry measurements illustrated that, although the europium-free sample is an excellent negative contrast agent with a high r2 relaxivity, it does not show a positive contrast enhancement as the concentration of nanoparticles increases. By increasing the europium to x = 0.15, r1 relaxivity increased significantly. On the contrary, europium substitution decreased r2 relaxivity due to a reduction in saturation magnetization. The ratio of r2/r1 decreased from 152 for the europium-free sample to 11.2 for x = 0.15, which indicates that Mn0.6Zn0.4Eu0.15Fe1.85O4 is a suitable candidate for dual-mode MRI contrast agent potentially. The samples with citric acid coating had higher r1 and lower r2 relaxivities than those of pluronic F127-coated samples.

17 January 2022 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
SISerhat Ilbey
Serhat Ilbey
PJPia M. Jungmann
Pia M. Jungmann
JFJohannes Fischer
Johannes Fischer
MJMatthias Jung
Matthias Jung
MBMichael Bock
Michael Bock
AÖAli Caglar Özen
Ali Caglar Özen
Purpose: To accelerate the Pointwise Encoding Time Reduction with Radial Acquisition (PETRA) sequence using compressed sensing while preserving the image quality for high‐resolution MRI of tissue with ultra‐short values.Methods: Compressed sensing was introduced in the PETRA sequence (csPETRA) to accelerate the time‐consuming single point acquisition of the k‐space center data. Random undersampling was applied to achieve acceleration factors up to Acc = 32. Phantom and in vivo images of the knee joint of six volunteers were measured at 3T using csPETRA sequence with Acc = 4, 8, 12, 16, 24, and 32. Images were compared against fully sampled PETRA data (Acc = 1) for structural similarity and normalized‐mean‐square‐error. Qualitative and semi‐quantitative analyses were performed to assess the effect of the acceleration on image artifacts, image quality, and delineation of anatomical structures at the knee.Results: Even at high acceleration factors of Acc = 16 no aliasing artifacts were observed, and the anatomical details were preserved compared with the fully sampled data. The normalized‐mean‐square‐error was less than 1% for Acc = 16, in which single point imaging acquisition time was reduced from 165 to 10 s, reducing the total scan time from 7.8 to 5.2 min. Semi‐quantitative analyses suggest that Acc = 16 yields comparable diagnostic quality as the fully sampled data for knee imaging at a scan time of 5.2 min.Conclusion: csPETRA allows for ultra‐short imaging of the knee joint in clinically acceptable scan times while maintaining the image quality of original non‐accelerated PETRA sequence.

23 June 2023 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
AÖAli Caglar Özen
Ali Caglar Özen
SISerhat Ilbey
Serhat Ilbey
FJFeng Jia
Feng Jia
DIDjaudat Sh Idiyatullin
Djaudat Sh Idiyatullin
MGMichael Garwood
Michael Garwood
MBMichael Bock
Michael Bock
Purpose: To improve intraoral transverse loop coil design for high‐resolution dental MRI.Methods: The transverse intraoral loop coil (tLoop) was modified (mtLoop) by overlapping the feed port conductors, bending the posterior section, introducing a parallel plate capacitor, optimizing the insulation thickness, and using it in receive‐only mode. In addition, an MR‐silent insulation was introduced. The performances of the mtLoop and tLoop coils were compared in terms of sensitivity, image SNR, and eddy currents using electromagnetic simulations and MRI measurements at 3T.Results: The receive‐only mode of the mtLoop increases the sensitivity at the apices of the roots, and the overlapped feed port design eliminated signal voids along the incisors. The bent posterior section with the parallel plate capacitor reduced the unwanted signal of the tongue by a factor of 2.3 in the selected region off interest and lowered the eddy currents by 10%. The proposed new coil provided higher SNR by elevenfold and 2.5‐fold at the incisors and apices of the molar roots within the selected regions of interest, respectively, in the experiments, as well as improved comfort. Optimal insulation thickness was determined as 1 mm. With the mtLoop, a (250 μm)3 isotropic resolution of the dental arch could be realized using a UTE sequence within 2 min total acquisition time. A T2‐SPACE protocol with (350 μm)2 in‐plane resolution was also demonstrated.Conclusion: The proposed new coil offers higher SNR at the incisors and apices of the molar roots, less unwanted signals from tongue, lower eddy currents, and improved patient comfort.