Xin Shen

Xin Shen

Auto-generated profile, based on publicly available information

Xin Shen

Radiology and Biomedical Imaging, University of California San Francisco, CA, USA

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 September 2022 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
XSXin Shen
Xin Shen
AÖAli Caglar Özen
Ali Caglar Özen
ASAntonia Sunjar
Antonia Sunjar
SISerhat Ilbey
Serhat Ilbey
SSStephen Sawiak
Stephen Sawiak
Uzay EmirUzay Emir
Uzay Emir
Purpose: This study aimed to develop a new 3D dual‐echo rosette k‐space trajectory, specifically designed for UTE MRI applications. The imaging of the ultra‐short transverse relaxation time (uT2) of brain was acquired to test the performance of the proposed UTE sequence.Theory and Methods: The rosette trajectory was developed based on rotations of a “petal‐like” pattern in the kx–ky plane, with oscillated extensions in the kz‐direction for 3D coverage. Five healthy volunteers underwent 10 dual‐echo 3D rosette UTE scans with various TEs. Dual‐exponential complex model fitting was performed on the magnitude data to separate uT2 signals, with the output of uT2 fraction, uT2 value, and long‐T2 value.Results: The 3D rosette dual‐echo UTE sequence showed better performance than a 3D radial UTE acquisition. More significant signal intensity decay in white matter than gray matter was observed along with the TEs. The white matter regions had higher uT2 fraction values than gray matter (10.9% ± 1.9% vs. 5.7% ± 2.4%). The uT2 value was approximately 0.10 ms in white matter .Conclusion: The higher uT2 fraction value in white matter compared to gray matter demonstrated the ability of the proposed sequence to capture rapidly decaying signals.

1 December 2020 in European Journal of Pharmaceutics and Biopharmaceutics
Verified
Journal Article
Closed access
YWYidan Wei
Yidan Wei
YHYingli Hu
Yingli Hu
XSXin Shen
Xin Shen
XZXin Zhang
Xin Zhang
JGJian Guan
Jian Guan
SMShirui Mao
Shirui Mao

25 March 2024 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
XSXin Shen
Xin Shen
ECEduardo Caverzasi
Eduardo Caverzasi
YYYang Yang
Yang Yang
XLXiaoxi Liu
Xiaoxi Liu
AGAri Green
Ari Green
PLPeder Larson
Peder Larson

22 July 2025 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
SASeyma Alcicek
Seyma Alcicek
ACAlexander R. Craven
Alexander R. Craven
XSXin Shen
Xin Shen
MCMark Chiew
Mark Chiew
AOAli Ozen
Ali Ozen
Uzay EmirUzay Emir
Uzay Emir
Purpose: This study aims (1) to implement a robust acquisition, fully automated reconstruction, and processing pipeline using a novel rosette k‐space pattern for UTE 31P 3D MRSI and (2) to evaluate the clinical applicability and reproducibility at different experimental setups.Methods: A multi‐center feasibility/reproducibility study was conducted for the novel UTE 31P 3D MRSI sequence with rosette petal trajectory (PETALUTE) at three institutions with different experimental setups (Siemens Prisma with volume head coil or surface coil, Siemens Biograph mMR with volume head coil). Five healthy subjects at each site were measured with an acquisition delay of 65 μs and a final resolution of 10 × 10 × 10 mm3 in 9 min. The measurement was repeated three times and averaged for the spectral analysis using the LCModel package. The potential for acceleration was assessed using compressed sensing on retrospectively undersampled data. Reproducibility at each site was evaluated using the inter‐subject coefficient of variance.Results: This novel acquisition and advanced processing techniques yielded high‐quality spectra and enabled the detection of the critical brain metabolites at three different sites with different hardware specifications. In vivo, feasibility with an acceleration factor of 4 in 6.75 min resulted in a mean Cramér‐Rao lower bounds below 20% for phosphocreatine (PCr), adenosine triphosphate (ATP), phosphomonoesters (PME), and a mean coefficient of variation for ATP/PCr below 20%.Conclusion: We demonstrated that UTE 31P 3D rosette MRSI acquisition, combined with compressed sensing and LCModel analysis, allows clinically feasible, robust, high‐resolution 31P MRSI to be acquired at clinical setups.

30 January 2024 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
NDNikhil Deveshwar
Nikhil Deveshwar
JYJingwen Yao
Jingwen Yao
MHMisung Han
Misung Han
NDNicholas Dwork
Nicholas Dwork
XSXin Shen
Xin Shen
PLPeder Larson
Peder Larson

3 May 2024 in medRxiv
Verified
Preprint
Open access
PDF file
CVCameron X. Villarreal
Cameron X. Villarreal
XSXin Shen
Xin Shen
AAAhmad Abdulrahman Alhulail
Ahmad Abdulrahman Alhulail
NBNicholas M. Buffo
Nicholas M. Buffo
XZXiaopeng Zhou
Xiaopeng Zhou
DCDeva Chan
Deva Chan
In this work, we demonstrate the sodium magnetic resonance imaging (MRI) capabilities of a three-dimensional (3D) dual-echo ultrashort echo time (UTE) sequence with a novel rosette petal trajectory (PETALUTE), in comparison to the 3D density-adapted (DA) radial spokes UTE sequence. We scanned five healthy subjects using a 3D dual-echo PETALUTE acquisition and two comparable implementations of 3D DA-radial spokes acquisitions, one matching the number of k-space projections (Radial – Matched Spokes) and the other matching the total number of samples (Radial – Matched Samples) acquired in k-space. The PETALUTE acquisition enabled equivalent sodium quantification in articular cartilage volumes of interest (168.8 ± 29.9 mM) to those derived from the 3D radial acquisitions (171.62 ± 28.7 mM and 149.8 ± 22.2 mM, respectively). We achieved a 41% shorter scan time of 2:06 for 3D PETALUTE, compared to 3:36 for 3D radial acquisitions. We also evaluated the feasibility of further acceleration of the PETALUTE sequence through retrospective compressed sensing with 2× and 4× acceleration of the first echo and showed structural similarity of 0.89 ± 0.03 and 0.87 ± 0.03 when compared to non-retrospectively accelerated reconstruction. Together, these results demonstrate improved scan time with equivalent performance of the PETALUTE sequence compared to the 3D DA-radial sequence for sodium MRI of articular cartilage.