Elena Macrelli

Dr. Elena Macrelli

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 January 2023 in Sensors
Verified
Journal Article
Open access
PDF file
MSMichele Sintoni
Michele Sintoni
EMElena Macrelli
Elena Macrelli
Alberto BelliniAlberto Bellini
Alberto Bellini
Claudio BianchiniClaudio Bianchini
Claudio Bianchini
In this paper, a diagnostic procedure for rotor bar faults in induction motors is presented, based on the Hilbert and discrete wavelet transforms. The method is compared with other procedures with the same data, which are based on time–frequency analysis, frequency analysis and time domain. The results show that this method improves the rotor fault detection in transient conditions. Variable speed drive applications are common in industry. However, traditional condition monitoring methods fail in time-varying conditions or with load oscillations. This method is based on the combined use of the Hilbert and discrete wavelet transforms, which compute the energy in a bandwidth corresponding to the maximum fault signature. Theoretical analysis, numerical simulation and experiments are presented, which confirm the enhanced performance of the proposed method with respect to prior solutions, especially in time-varying conditions. The comparison is based on quantitative analysis that helps in choosing the optimal trade-off between performance and (computational) cost.

8 January 2023 in Machines
Verified
Journal Article
Open access
PDF file
Claudio BianchiniClaudio Bianchini
Claudio Bianchini
GBGiorgio Bisceglie
Giorgio Bisceglie
ATAmbra Torreggiani
Ambra Torreggiani
MDMatteo Davoli
Matteo Davoli
EMElena Macrelli
Elena Macrelli
MFMatteo Frigieri
Matteo Frigieri
Interior permanent-magnet synchronous machines are widely spreading in automotive and vehicle traction applications, because of their high efficiency over a wide speed range. This capability can be achieved by appropriated control strategies: Maximum Torque per Ampere (MTPA), Flux Weakening (FW) and Maximum Torque per Volt (MTPV). However, these control trajectories are often based on an simplified magnetic model of the electrical machine. In order to improve the evaluation of machine output capabilities, nonlinear magnetic behavior must be modeled. This is not only related to the final application with a given drive and control structure, but also during the design process of the electric machine. In the design process, the output torque Vs. speed characteristic must be calculated following MTPA, MTPV and FW in the most accurate way to avoid significant error. This paper proposes a set of algorithms to compute MTPA, FW and MTPV curves for interior permanent-magnet synchronous machines taking into account the machines’ nonlinearities caused by iron saturation and compares differed approaches to highlight the torque–speed capabilities for the same machine following different methods. The algorithms are based on the maps of the equivalent inductances of a reference interior permanent-magnet synchronous machine and inductances maps were obtained via 2-D Finite Element Analysis over the machine’s operating points in id−iq reference plane. The effects of different 2-D finite element methods are also computed by both standard nonlinear magnetostatic simulations and Frozen Permeability simulations. Results show that the nonlinear model computed via frozen permeability is more accurate than the conventional linear and nonlinear models computed via standard magnetostatic simulations; for this reason, during the electrical machine design, it is important to check the expected performance employing a complete inductance map and frozen permeability.

1 September 2024
Verified
Conference Paper
Closed access
Claudio BianchiniClaudio Bianchini
Claudio Bianchini
GSGiada Sala
Giada Sala
MFMatteo Frigieri
Matteo Frigieri
MVMattia Vogni
Mattia Vogni
NGNICOLA GIANNOTTA
NICOLA GIANNOTTA
EMElena Macrelli
Elena Macrelli
This paper presents a new extended constant power region control model for interior permanent magnet synchronous machine (IPMSM) powered by a current source inverter (CSI). The IPMSM constant power region is usually obtained with voltage source inverter (VSI) employing flux weakening (FW) and maximum torque per volt (MTPV) control strategy when the voltage at the motor terminal exceed the available DC BUS voltage. This is due to the fact that VSI essentially operates as a step down converter. Even if these control strategy are well know in literature their implementation is always critical, specially when the MTPV is needed. As CSI is intrinsically a step up converter, it is possible to delay FW operation, provided that the voltage applied to the motor does not exceed the voltage rating of the power devices and the limits for the insulation system. So, in order to obtain a wide constant power region, an extend MTPA-FW is here proposed avoiding the need of MTPV and taking the advantage of the step-up intrinsic capability of the CSI.

20 January 2026 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
MVMattia Vogni
Mattia Vogni
GSGiada Sala
Giada Sala
EMElena Macrelli
Elena Macrelli
Claudio BianchiniClaudio Bianchini
Claudio Bianchini
Alberto BelliniAlberto Bellini
Alberto Bellini
Accurate loss modeling in electric machines is a critical enabler for design optimization. By providing more faithful estimates of thermal stress, loss models may also contribute to extended insulation and permanent-magnet lifetimes. Loss modeling has been widely investigated, and existing approaches can be broadly grouped into three classes: (i) analytical models; (ii) numerical finite-element (FEA) methods; and (iii) hybrid schemes that combine analytical formulations with numerical field solutions. Ironless (coreless) machines constitute a special case for AC loss prediction. In such topologies, iron-core losses are essentially absent, so winding AC losses tend to dominate, and magnet losses may become non-negligible under high-frequency excitation. AC losses of these machines, which are suitable for FESS applications, have been under-investigated in literature. This paper presents a comprehensive loss model for ironless machines that jointly treats winding and magnet losses and distinguishes between fundamental and carrier-frequency components for both coils and magnets. The framework is experimentally assessed on a prototype for a flywheel energy storage system (FESS) application. A current source inverter (CSI) supply appears to reduce AC losses and current ripple relative to a conventional voltage source inverter (VSI), suggesting potential efficiency and thermal advantages for ironless drives under comparable conditions.