Vicarious calibration is the determination of an on-orbit sensor’s radiometric response using measurements over test sites such as Railroad Valley (RRV), Nevada. It has the highest accuracy when a remote sensor’s view angle is aligned with that of the surface measurements, namely at a nadir view. For view angles greater than 10°, the dominant error is the uncertainty in the off-nadir correction factor. The factor is largest in the back-scatter principal plane and can reach 20%. The Orbiting-Carbon Observatory has access to a number of datasets to determine this deviation. These include measurements from field instruments such as the Portable Apparatus for Rapid Acquisition of Bidirectional Observation of the Land and Atmosphere (PARABOLA), as well as satellite measurements from Multi-angle Imaging SpectroRadiometer (MISR) and MODerate resolution Imaging Spectroradiometer (MODIS). The correction factor derived from PARABOLA is consistent in time and space to within 2% for view angles as large as 30°. Field spectrometer data show that the correction term is spectrally invariant. For this reason, a time-invariant model of RRV surface reflectance, along with empirically derived coefficients, is sufficient to use in the calibration of off-nadir sensors, provided there has been no recent rainfall. With this off-nadir correction, calibrations can be expected to have uncertainties within 5%.
The objective of the Ground to Space CALibration Experiment (G-SCALE) is to demonstrate the use of convex mirrors as a radiometric and spatial calibration and validation technology for Earth Observation assets, operating at multiple altitudes and spatial scales. Specifically, point sources with NIST-traceable absolute radiance signal are evaluated for simultaneous vicarious calibration of multi- and hyperspectral sensors in the VNIR/SWIR range, aboard Unmanned Aerial Vehicles (UAVs), manned aircraft, and satellite platforms. We introduce the experimental process, field site, instrumentation, and preliminary results of the G-SCALE, providing context for forthcoming papers that will detail the results of intercomparison between sensor technologies and remote sensing applications utilizing the mirror-based calibration approach, which is scalable across a wide range of pixel sizes with appropriate facilities. The experiment was carried out at the Rochester Institute of Technology’s Tait Preserve in Penfield, NY, USA on 23 July 2021. The G-SCALE represents a unique, international collaboration between commercial, academic, and government entities for the purpose of evaluating a novel method to improve vicarious calibration and validation for Earth Observation.