Vaishnavi M Nayak

Dr. Vaishnavi M Nayak


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 January 2025 in F1000Research
Verified
Journal Article
Open access
PDF file
KSKavishma Sulaya
Kavishma Sulaya
SVSwapna B V
Swapna B V
VNVaishnavi M Nayak
Vaishnavi M Nayak
Objective To analyze the effectiveness of various techniques available for printing, finishing and polishing of 3D printed prosthesis. Methods The articles were selected from electronic databases including PubMed and Scopus. Recently, lot of advancements have been observed in the field of 3D printing in dentistry. Results Numerous studies were found explaining the factors affecting the surface roughness such as printing speed, direction, layer thickness, post curing, etc., and the significance in achieving a smooth surface finish of a 3D printed prosthesis. The methods employed to achieve this range, similar to conventional and chairside polishing, are to use advanced coating materials such as light cured glazes to nanoparticles. Conclusion 3D printing is being used in day-to-day practice and the prosthesis must be aesthetic looking to satisfy the patients’ expectations. There is a lack of data supporting any one polishing method for the prosthesis. There is a need for further research on the existing techniques and newer advancements yielding aesthetic prostheses with an optimal surface finish.

23 October 2024 in F1000Research
Verified
Journal Article
Open access
PDF file
KSKavishma Sulaya
Kavishma Sulaya
SVSwapna B V
Swapna B V
VNVaishnavi M Nayak
Vaishnavi M Nayak
Objective To analyze the effectiveness of various techniques available for printing, finishing and polishing of 3D printed prosthesis. Methods The articles were selected from electronic databases including PubMed and Scopus. Recently, lot of advancements have been observed in the field of 3D printing in dentistry. Results Numerous studies were found explaining the factors affecting the surface roughness such as printing speed, direction, layer thickness, post curing, etc., and the significance in achieving a smooth surface finish of a 3D printed prosthesis. The methods employed to achieve this range, similar to conventional and chairside polishing, are to use advanced coating materials such as light cured glazes to nanoparticles. Conclusion 3D printing is being used in day-to-day practice and the prosthesis must be aesthetic looking to satisfy the patients’ expectations. There is a lack of data supporting any one polishing method for the prosthesis. There is a need for further research on the existing techniques and newer advancements yielding aesthetic prostheses with an optimal surface finish.

26 November 2024 in Journal of Oral Biology and Craniofacial Research
Verified
Journal Article
Open access
SVSwapna B V
Swapna B V
VNVaishnavi M Nayak
Vaishnavi M Nayak
KSKavishma Sulaya
Kavishma Sulaya
SSSmitha Sammith Shetty
Smitha Sammith Shetty
Intraoral scanners used for the fabrication of milled and 3D-printed complete dentures simplify the procedure. However, its effectiveness in recording the functional peripheral seal area needs to be researched. Therefore, this study aims to assess the retention of conventional, milled and 3D-printed denture bases made from conventional impression technique and digital scans in different types of post palatal seal area. Completely edentulous participants were divided into group A and group B based on type of posterior palatal seal area. Each group received three denture bases fabricated using compression molding, milling and 3D printing. The retention was evaluated using a digital dynamometer at 45° and 90° inclination. The ANOVA test revealed statistically significant difference in the retention of denture bases fabricated using three different techniques. When compared between the three groups at 45 and 90°, statistically significant difference in the retentive values between the control and other two groups were observed. All three of the fabrication processes have retention that falls within a clinically acceptable range. 3D printed dentures had better adaptation on the PPS area whereas the milled dentures had a better peripheral seal although the conventional process showed highest retention values.

1 August 2025 in Prosthesis
Verified
Journal Article
Open access
PDF file
SVSwapna B V
Swapna B V
Basavannadevaru ShivamurthyBasavannadevaru Shivamurthy
Basavannadevaru Shivamurthy
VGVinu Thomas George
Vinu Thomas George
KSKavishma Sulaya
Kavishma Sulaya
VNVaishnavi M Nayak
Vaishnavi M Nayak
Background/Objectives: Additive manufacturing (AM) technology has emerged as an innovative approach in dentistry. Recently, manufacturers have developed permanent resins engineered explicitly for the fabrication of definitive prostheses using AM techniques. This systematic review evaluated the mechanical and physical properties of 3D-printed permanent resins in comparison to milled resins and hybrid ceramics for the fabrication of indirect dental restorations. Methods: Three electronic databases—Scopus, Web of Science, and PubMed—were searched for English-language articles. Two independent researchers conducted study selection, data extraction, quality assessment, and the evaluation of the certainty of evidence. In vitro studies assessing the mechanical and physical properties of the permanent resins were included in this review. Results: A total of 1779 articles were identified through electronic databases. Following full-text screening and eligibility assessment, 13 studies published between 2023 and 2024 were included in this qualitative review. The investigated outcomes included physical properties (surface roughness, color changes, water sorption/solubility) and mechanical properties (flexural strength, elastic modulus, microhardness). Conclusions: Three-dimensionally printed permanent resins show promising potential for fabricating indirect dental restorations. However, the current evidence regarding their mechanical and physical properties remain limited and inconsistent, mainly due to variability in study methodologies.

8 October 2025 in IEEE Access
Verified
Journal Article
Open access
RBR Srikar Bharadwaj
R Srikar Bharadwaj
VNVaishnavi M Nayak
Vaishnavi M Nayak
NPNayana Prabhu
Nayana Prabhu
PSPrajwal Shenoy
Prajwal Shenoy
Dental implants are an effective solution for tooth loss, offering long-term success rates exceeding 95%. However, challenges such as surgical complications, improper implant position, and prosthetic inaccuracies persists, often due to operator inexperience or anatomical complexities. Previously, Static Computer-Assisted Implant Surgery (sCAIS) and Dynamic Navigation Systems (DNS) have shown improved precision in implant placement. However, sCAIS often incurs high costs and manufacturing delays, while DNS faces challenges like line-of-sight issues and magnetic interference. Inertial measurement units (IMUs) present a promising alternative, offering real-time orientation feedback with advantages such as low cost, portability, and no line-of-sight restrictions. Despite their potential, research on IMU-based guidance for dental implant placement is limited, with unresolved issues related to accuracy under drilling vibrations, device miniaturization, and clinical usability. This paper presents the design and validation of a compact IMU-based system that measures handpiece angulation in real-time, transmitting mesiodistal and buccolingual orientation data to a wireless clinician-worn watch. A thorough validation was conducted to measure both the static and dynamic accuracies, as well as the response time of the system when exposed to dental handpiece drill vibrations. The impact of the built-in filtering features of the IMU and various tuning parameters on performance was also assessed. The validation results indicate that the IMU-assisted implantology device is a cost-effective and adaptable solution for precise implant placement.