Muhammad Aswin

Dr. Muhammad Aswin

Civil Engineering, University of North Sumatra, Medan, Sumatera Utara, Indonesia
Senior Lecturer

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2016 in Structures
Verified
Journal Article
Closed access
BMBashar Mohammed
Bashar Mohammed
Muhammad AswinMuhammad Aswin
Muhammad Aswin
WBWalden Harry Beatty
Walden Harry Beatty
MHMuhammad Hafiz
Muhammad Hafiz

3 November 2016 in Advances in Materials Science and Engineering
Verified
Journal Article
Open access
PDF file
BMBashar Mohammed
Bashar Mohammed
MNM. F. Nuruddin
M. F. Nuruddin
Muhammad AswinMuhammad Aswin
Muhammad Aswin
NMNursyuhada Mahamood
Nursyuhada Mahamood
HAHashem Al-Mattarneh
Hashem Al-Mattarneh
Eight large-scale reinforced self-compacted engineered cementitious composite (R-SC-ECC) beams with different steel reinforcement ratios have been designed, prepared, cast, cured, and tested to failure at the age of 28 days. The experimental results have been compared with theoretical values predicted using EC2, RILEM, and VecTor2 models. Results show that failure modes in flexure and shear of R-SC-ECC beams are comparable to that of normal reinforced concrete beam. Nevertheless, contrary to VecTor2, models of EC2 and RILEM are not suitable for predicting reasonable ultimate moments for the beams, while results using VecTor2 model have successfully predicted the failure modes and load-deflection curves for all R-SC-ECC beams. It has been concluded that R-SC-ECC fall in the category of ductility class medium to high which gives advantages of using R-SC-ECC beams in regions susceptible to seismic activities.

2 September 2019 in International Journal of Concrete Structures and Materials
Verified
Journal Article
Open access
PDF file
BMBashar Mohammed
Bashar Mohammed
Muhammad AswinMuhammad Aswin
Muhammad Aswin
MLM. S. Liew
M. S. Liew
Noor Amila ZawawiNoor Amila Zawawi
Noor Amila Zawawi
Twenty-seven large-scale beams with dapped-end have been prepared, cast and tested to failure in the three points loading arrangement. One control beam has been designed in accordance with...

26 May 2020 in Materials
Verified
Journal Article
Open access
PDF file
MLM. S. Liew
M. S. Liew
Muhammad AswinMuhammad Aswin
Muhammad Aswin
KDKamaluddeen Usman Danyaro
Kamaluddeen Usman Danyaro
BMBashar Mohammed
Bashar Mohammed
AAAhmad Mahamad Al-Yacouby
Ahmad Mahamad Al-Yacouby
In relation to the use of retrofit materials on damaged constructions, application on earthquake-resistant buildings, and for the strengthening and rehabilitation on weakened regions, there is a need for a more superior material than concrete. Application sites include beam-column joints, corbels, link-slabs, deep beams, support regions and dapped-end areas. Fiber reinforced engineered cementitious composites (FR-ECC) can address this issue, because FR-ECC is one of the composite materials that has high strength, ductility and durability. In order to develop FR-ECC, this study was done to investigate the effect of adding quartz powder on the compressive strength capacity and properties of FR-ECC through the use of polyvinyl alcohol (PVA) and steel fibers. The volume fraction of fiber was set to 0%–2%. To support the friendly environment, FR-ECC uses by-product materials such as fly ash and silica fume, with a cement content less than 600 kg/m3. In terms of the experimental investigation on FR-ECC, this work conducted the fresh property tests showing that PVA fibers have quite an influence on ECC workability, due to their hydrophilic behavior. By adjusting the superplasticizer (SP) content, the consistency and high workability of the ECC mixes have been achieved and maintained. The test results indicated that the PVA and steel fibers-based ECC mixes can be classified as self-compacting composites and high early compressive strength composites. Significantly, addition of quartz powder into the ECC mixes increased the compressive strength ratio of the ECC samples up to 1.0747. Furthermore, the steel fiber-based ECC samples exhibited greater compressive strength than the PVA fibers-based ECC samples with the strength ratio of 1.1760. Due to effect of the pozzolanic reaction, the fibers dispersion and orientation in the fresh ECC mixes, so that the cementitious matrices provided the high strength on the FR-ECC samples. During the compression loading, the bulging effect always occurred before the failures of the fibers-based ECC samples. No spalling occurred at the time of rupture and the collapse occurred slowly. Thus, FR-ECC has provided unique characteristics, which will reduce the high cost of maintenance.

3 January 2023 in Buildings
Verified
Journal Article
Open access
PDF file
Muhammad AswinMuhammad Aswin
Muhammad Aswin
Amin Al-FakihAmin Al-Fakih
Amin Al-Fakih
ZSZubair Syed
Zubair Syed
MLM. S. Liew
M. S. Liew
Severe damage or collapse of reinforced concrete dapped-end beams (RC-DEBs) may occur during the service life. The collapse of the Concorde overpass structure in Laval, Quebec, Canada, in 2006 revealed the causes of collapse, i.e., insufficient shear strength (no stirrups), misplacement of hanger reinforcement, etc. In addition, the inspection report of RC half-joint bridges in England until 2018 expressed that damages or failures of half-joint structures can be attributed to the poor condition of structures or non-compliant reinforcement detailing. These conditions exhibited how important it is to understand the proper detailing of dapped-end reinforcement. To date, some studies have performed investigations on the effect of inadequate dapped-end reinforcement on the structural behavior of DEBs. However, the results of the research to date were not yet complete enough to disclose the role of each group of dapped-end reinforcement in resisting the working load. Therefore, this study was carried out to investigate the main role of each group of dapped-end reinforcement separately on the structural performance of RC-DEBs. Eight large-scaled RC-DEBs (with sizes of 1800 mm length, 120 mm width and 250 mm height) were prepared, cast and cured. All DEB specimens were tested under the three-point loading up to failure. To localize the effect of shear failure, the shear span-depth ratio (av⁄d) of 1.43 was set. Test results exhibited that arrangement of a specific group of dapped-end reinforcement separately affects the structural performance of DEBs significantly. The diagonal reinforcement (DR) group was found to be more effective than the vertical hanger reinforcement (HR) group. The failure load capacity of the DR group (DEB-18) achieved 0.29 times that of the control beam (DEB-3). Meantime, the nib flexure reinforcement (NFR) group demonstrated the most important role in the structural performance of DEBs compared to other dapped-end reinforcement groups. The failure load capacity of the NFR group (DEB-39) reached 0.62 times that of the control beam, while rupture deflection of the NFR group also exhibited the highest value than other groups, i.e., 0.62 times that of the control beam. In addition, analysis results of rosette strain gages (RSGs) data indicated that regions near to re-entrant corner and its vicinity experienced the highest stress concentration factor (SCF) compared to other places of the beams. These regions were more susceptible to experiencing the first crack, progressive crack, damage or failure first than other regions of DEBs. The greater the value of SCF, the greater the probability of collapse occurring in the related structural elements, which is also followed by a lower failure load capacity. DEB-1 (without dapped-end reinforcement) has the highest SCF (205.68), and the lowest failure load capacity (12.58 kN), whilst DEB-3 (with the complete dapped-end reinforcement) has the lowest SCF (79.62), but the highest failure load capacity (105.26 kN). Obviously, DEB-3 can withstand the working load properly. Its adequate dapped-end reinforcement is able to accommodate and distribute the high stress flows in the dapped-end region properly, which causes the SCF value to decrease.

1 December 2020 in Case Studies in Construction Materials
Verified
Journal Article
Open access
BMBashar S. Mohammed
Bashar S. Mohammed
Muhammad AswinMuhammad Aswin
Muhammad Aswin
MLM.S. Liew
M.S. Liew