Aya Mousa

Ms. Aya Mousa

Energy Engineering Department, Al Hussein Technical University, Amman, Al ‘Āşimah, Jordan
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 November 2021 in Processes
Verified
Journal Article
Open access
PDF file
Malek AlkasrawiMalek Alkasrawi
Malek Alkasrawi
EAEmad Abdelsalam
Emad Abdelsalam
HAHamza Alnawafah
Hamza Alnawafah
Fares ALMOMANIFares ALMOMANI
Fares ALMOMANI
Muhammad TawalbehMuhammad Tawalbeh
Muhammad Tawalbeh
AMAya Mousa
Aya Mousa
This work explores the technical possibilities of increasing the efficiency of a standard solar chimney power plant (SCPP) by integrating it with photovoltaic (PV) panels. The integration is possible by using the collector circumference to install the PV collectors, which provide a heat sink, allow for the better harvesting of the solar radiation, and increase energy production. The new design led to an increase in the annual electricity production from 380 to 494 MWh and water production from 278 to 326 k tons/year compared with the standard SCPP, marking an increase of 30% and 17%, respectively. The results also show that the integration reduced the greenhouse gas emissions (GHG), the localized cost of energy, and the capital cost of investment by 30%, 36%, and 20%, respectively. The proposed design supports the sustainable replacement of the existing desalination plants with zero operational costs and an excellent reduction in greenhouse gas emissions.

18 January 2023 in Energies
Verified
Journal Article
Open access
PDF file
EAEmad Abdelsalam
Emad Abdelsalam
HAHamza Alnawafah
Hamza Alnawafah
Fares ALMOMANIFares ALMOMANI
Fares ALMOMANI
AMAya Mousa
Aya Mousa
Mohammad JamjoumMohammad Jamjoum
Mohammad Jamjoum
Malek AlkasrawiMalek Alkasrawi
Malek Alkasrawi
Overheating of photovoltaic (PV) panels decreases their efficiency and lifetime, and subsequently increases the levelized cost of energy (LCOE). Passive PV cooling would enhance the PV operational stability and durability. The cooling tower (CT) technology offers an attractive approach for zero-cost capability. In this work, we developed and customized a CT specific for passive PV cooling. Since the dense downdrafted cooled air gained high velocity, a turbine was installed at the bottom of the CT for power production. At the height’s ambient temperature, the CT cooled the air from 50 °C down to 30 °C. The cooled air at 30 °C has enough capacity to cool the PV panels. This cooling capacity improved the average annual efficiency of the PV panels by 6.83%. The design specifications of the CT have the highest performance, with the maximum radius of PV area of panels that can be cooled at 50 m. Furthermore, the current design could operate during the night for power production with minimum operational cost.

12 October 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
EAEmad Abdelsalam
Emad Abdelsalam
HAHamza Alnawafah
Hamza Alnawafah
Fares ALMOMANIFares ALMOMANI
Fares ALMOMANI
AMAya Mousa
Aya Mousa
HQHassan Qandil
Hassan Qandil
This work presents a novel approach to increasing the efficiency of photovoltaic (PV) panels by integrating them with a cooling tower (CT). An infusion of water cools the hot, dry ambient air at the top of the CT. Due to gravity, the cooled air drops toward the base of the CT, where it interacts with a turbine placed at the bottom of the CT to produce electricity. The air then exits the CT base, creating a cooled air jet stream. The PV panels were placed at the base of the CT, right at the stream’s exit. As the cooled air passes underneath the PV panels, it exchanges energy with the PV, reducing the panels’ temperature. The results showed that the maximum annual efficiency improvement (6.831%) was observed using two rows of PV panels. The efficiency declined incrementally from 6.831% to 4.652% when the number of rows of PV panels was increased from two to twelve. The results also showed a significant improvement in the temperature of the PV panels. The best results were obtained at noon (maximum ambient temperature), where the solar panel temperature was lowered to 25 °C from 55 °C. Furthermore, the annual electrical energy generated with two rows of panels was 39,207.4 kWh without the CT, compared to 41,768.2 kWh with the CT. In addition, the results showed that with a 10 m diameter and 200 m height CT, the maximum number of PV rows that can be effectively cooled is 24. Future work will investigate integrating additional techniques to improve the system’s efficiency further.