Farzad Mir

Farzad Mir

Electrical and Computer Engineering, University of Houston, Houston, Texas, USA
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 February 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Ladislau MatekovitsLadislau Matekovits
Ladislau Matekovits
Farzad MirFarzad Mir
Farzad Mir
GDGianluca Dassano
Gianluca Dassano
Ildiko PeterIldiko Peter
Ildiko Peter
The design and experimental verification of a deeply implanted conformal printed antenna is presented. The hip implant acts as the ground plane for a coaxial-cable-fed trapezoidal radiator designed to transmit biological signals collected within the body by proper biosensors. The arrangement, consisting of a metallic (or equivalent) hip implant, bio-compatible gypsum-based dielectric, and conformal radiator, was tested when the hosting 3D-printed plastic bone was immersed in tissue-like liquid contained in a plastic bucket. The dimensions of the set-up are similar to a human leg. Matching and radiation characteristics are presented in the industrial, scientific, and medical (ISM) frequency band (2.4–2.5 GHz), showing the feasibility of the proposed arrangement.

6 January 2023 in Chips
Verified
Journal Article
Open access
PDF file
LRLuis Henrique Rodovalho
Luis Henrique Rodovalho
Pedro Filipe Leite Correia de ToledoPedro Filipe Leite Correia de Toledo
Pedro Filipe Leite Correia de Toledo
Farzad MirFarzad Mir
Farzad Mir
FEFarshad Ebrahimi
Farshad Ebrahimi
Inverter-based Operational Transconductance Amplifiers (OTAs) are versatile and friendly scalable analog circuit blocks. Especially for the new CMOS technological nodes, several recent applications have been extensively using them, ranging from Analog Front End (AFE) to analog-to-digital converters (ADC). This work tracks down the current advances in inverter-based OTAs design, comparing their basic fully differential structures, such as Nauta (N), Barthelemy (B), Vieru (V) and Mafredini (M) ones, and, in addition, mixing them up to propose new fully differential single-ended and two-stage hybrid versions. The new herein-proposed fully differential hybrid OTAs are the composition of Barthelemy/Nauta (B/N), Barthelemy/Manfredini (B/M), Nauta/Vieru (N/V), and Manfredini/Vieru (M/V) OTAs. All OTAs were designed using the same Global Foundries 180 nm open-source PDK and their performances are compared for post-layout simulations.

15 October 2020
Verified
Conference Paper
Closed access
Farzad MirFarzad Mir
Farzad Mir
Ladislau MatekovitsLadislau Matekovits
Ladislau Matekovits
Lida KouhalvandiLida Kouhalvandi
Lida Kouhalvandi
EGEce Gunes
Ece Gunes
This paper presents an automated design methodology for electromagnetic- based (EM-based) optimization of an array antenna by applying bottom-up approach. Firstly, one single antenna is optimized then bottom-up optimization (BUO) method has been implemented by increasing the number of single antennas, sequentially. The proposed method leads to automatically find an optimal array by setting the distance between single antennas. The optimization method is performed in an automated environment with the help of an electronic design automation (EDA) tool and a numerical analyzer. The results of the final design have been compared by means of two EDA tools such as ADS and HFSS. The optimized array antenna works in the frequency band from 12.9 GHz to 14.3 GHz. It offers a linear gain performance higher than 7.5 dB. The simulations in both ADS and HFSS tools illustrate a good match in S-parameter and gain simulation output results.

11 November 2025 in IEEE Transactions on Electromagnetic Compatibility
Verified
Journal Article
Closed access
Farzad MirFarzad Mir
Farzad Mir
MDMingtao Du
Mingtao Du
ZZZiyu Zuo
Ziyu Zuo
LYLijian Yang
Lijian Yang
NKNorbert Kaula
Norbert Kaula
JCJi Chen
Ji Chen
Transcutaneous electrical nerve stimulation (TENS) is a widely used modality for pain relief and neuromuscular rehabilitation. However, the presence of implantable orthopedic devices can significantly distort the surrounding electric field, potentially leading to unintended neuronal activation. This study examines the influence of such implants on nerve stimulation during TENS therapy through a combination of numerical modeling and experimental validation. Electromagnetic simulations and neurophysiological modeling using NEURON, based on an anatomically accurate human body model, demonstrate pronounced electric field distortions at the edges of implantable devices, resulting in a lowered activation threshold for adjacent neurons. These findings are corroborated by phantom experiments, which show substantial alterations in electric field distribution in the presence of orthopedic plates and screws. The results suggest that TENS application should maintain a safe distance from implantable devices to minimize the risk of inadvertent nerve activation.

19 April 2023
Verified
Conference Paper
Closed access
XYXiaolin Yang
Xiaolin Yang
Farzad MirFarzad Mir
Farzad Mir
JCJi Chen
Ji Chen
This study aims to investigate the impact of cerebral artery stent on the brain neuron activation under a wireless charging system. A simplified wireless charger model is developed and positioned in close proximity tothe head region. A cerebral artery stent is modeled and placed inside the brain vessels, and two distinct models are developed, one with the stent and one without it. To determine the electrical potential along a set of nerve fiber, Finite Element Method (FEM) based on the electromagnetic simulation software is employed. A high-frequency waveform is generated and scaled by the stimulus amplitude. Based on the potential distributions and stimulus waveform, the activation thresholds are obtained by setting stimulus amplitudes for the MRG (McIntyre-Richardson-Grill) myelinated fiber models. Results indicate thatthe presence of a cerebral artery stent can cause significant variations in the activation thresholds of brain neurons, up to 22%. As a result, it is imperative to consider the impact of cerebral artery stents on the activation thresholds of brain neurons under a wireless charging.

29 May 2022
Verified
Conference Paper
Closed access
Farzad MirFarzad Mir
Farzad Mir
ASAldo De Sabata
Aldo De Sabata
Ladislau MatekovitsLadislau Matekovits
Ladislau Matekovits
Design and analysis of a miniaturized tunable periodic structure using PIN diodes is presented. The behaviour of the structure for two different incidences of electromagnetic waves, namely TE and TM incidences, is reported in the frequency range between 2 and 14 GHz. To achieve a proper way to overcome the problems introduced by the biasing of the lumped elements, biasing microstrip lines have been designed. Special care in the design had to focus on the symmetry breaking introduced by the feeding lines. The proposed tunable metasurface exhibits broadband and multiband frequency response.