Yong-Zai Chang

Dr. Yong-Zai Chang


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 May 2023 in Coatings
Verified
Journal Article
Open access
PDF file
BRBaosheng Rong
Baosheng Rong
HLHao Li
Hao Li
HLHao Li
Hao Li
YCYong-Zai Chang
Yong-Zai Chang
YWYi Wang
Yi Wang
HFHanxiu Fan
Hanxiu Fan
Different types and amounts of steel fibers have varying effects on the improvement of concrete’s mechanical properties. In order to identify the most suitable steel fiber types for the practical production of prefabricated pavements and derive a formula to predict and evaluate the mechanical properties based on steel fiber volume fraction, this study conducted experimental research on the physical mechanical properties of concrete using the method of equal volume substitution of coarse aggregate. The influence of steel fiber type and volume fraction on the microstructure and failure mechanism of steel fiber reinforced concrete (SFRC) was analyzed through electron microscopy scanning. The mechanical properties of plain concrete were used as benchmark. The results showed that when the steel fiber volume fractions were 0.6% and 1.5%, the bending and split tensile strengths of milled steel fibers were 3.1% higher than those of hooked-end steel fibers and the compressive strength of SFRC was significantly increased by 13.5%. The comprehensive mechanical properties of wave-shaped steel fibers were inferior to the first two types. Considering the requirements of SFRC in engineering, milled steel fibers are more suitable to be concrete components. This is because the tangling property of the hooked-end steel fibers makes them difficult to be shaped. In contrast, the smooth surface of milled steel fibers exerts a smaller impact on the forming of specimen and they are more economical. The mechanical properties of SFRC improve as the volume fraction of steel fibers increases from 0% to 2%, but start to decline when the volume fraction exceeds 2%. A volume fraction of 0.6% for steel fibers is sufficient to meet the standard for bending and tensile strength in heavy-duty concrete pavements. Finally, the relationship expressions between the compressive strength, flexural strength, and split tensile strength of SFRC and the steel fiber volume fraction were obtained through fitting the experimental data using Origin software.

26 March 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
LWLi-Ming Wu
Li-Ming Wu
BRBaosheng Rong
Baosheng Rong
YCYong-Zai Chang
Yong-Zai Chang
FGFeng Gao
Feng Gao
BZBin ZHANG
Bin ZHANG
HFHan-Xiu Fan
Han-Xiu Fan
When constructing tunnels in mountainous areas, the drilling and blasting method is the most commonly used because of its economy. Ordinary reinforced concrete itself has defects such as poor crack resistance and brittleness. Therefore, when using the drilling and blasting method for ordinary reinforced concrete double-line tunnels, vibration phenomena will occur and cause cracks in the first-line tunnels, which will have adverse effects on the durability and safety of the tunnel. As a response, scholars have proposed the use of steel fiber-reinforced concrete as tunnel lining. In this paper, the LS-DYNA software is used to establish three models of plain concrete, ordinary concrete, and steel fiber-reinforced concrete, and numerical analysis is conducted with different amounts of explosives. The results show that the steel fiber-reinforced concrete tunnel lining has better performance than the other two concretes in tunnel construction.

18 November 2025 in Infrastructures
Verified
Journal Article
Open access
PDF file
WLWu Liming
Wu Liming
HHHu XinTong Huang
Hu XinTong Huang
YCYong-Zai Chang
Yong-Zai Chang
FGFeng Gao
Feng Gao
ZWZi Jian Wang
Zi Jian Wang
QLQi Liu
Qi Liu
In high-altitude highway tunnels, the efficiency of jet fans significantly impacts the performance and energy consumption of ventilation systems. To optimize jet fan efficiency under such conditions, this study combines outdoor model experiments with numerical simulations of physical models in longitudinal jet ventilation systems. A model was established using SpaceClaim (ANSYS 2022 R1), and numerical simulations were conducted using Fluent software (ANSYS 2022 R1) to obtain results. The effect of different mounting inclination angles (0° to 10°) on the performance of a jet fan was experimentally investigated, and a correlation formula for the lift pressure of the jet fan under different inclination angles was established. Comparative results demonstrate that the numerical simulations accurately capture the variation trend of fan lift pressure under different tilt angles observed in the experiments. Specifically, the lift pressure of the jet fan initially increases and then decreases with increasing tilt angle. Comparative analysis of pressure rise at installation angles of 0°, 2°, 3°, 4°, 5°, 6°, 8°, and 10° revealed that a peak pressure rise of 19.66 Pa was observed at 4° installation, demonstrating optimal performance at this angle. The velocity distribution indicates that tilt angles between 0° and 4° increase the airflow influence range, beyond which efficiency decreases due to kinetic energy loss at the base. The study determined that under these conditions, a jet fan installed at a 4° inclination angle exhibits optimal performance in high-altitude straight tunnels and is thus identified as the optimal installation angle. At this angle, both pressure-rise efficiency and airflow stability are effectively balanced; this configuration provides a critical design basis for energy-saving optimization in high-altitude tunnel ventilation systems.

20 August 2026 in Eng
Verified
Journal Article
Open access
PDF file
BZBin ZHANG
Bin ZHANG
RHRuizhe He
Ruizhe He
LMLijun Ma
Lijun Ma
YCYong-Zai Chang
Yong-Zai Chang
SYShijia Yuan
Shijia Yuan
PDPeng Ding
Peng Ding
To address the challenges associated with operational ventilation in high-altitude tunnels, this study investigates the distribution patterns of ventilation flow fields and optimizes the spatial layout parameters of jet fans to determine the most effective configuration. Using a case study from the Zhuohe Expressway tunnel, numerical simulations were conducted to analyze four key design parameters: the lateral clear distance (L) between two jet fans in a single group, the vertical distance (H) from the fan center to the tunnel lining, the axial distance (T) from the fan to the tunnel entrance, and the longitudinal spacing (S) between two groups of fans. The results indicate that for a single-fan group, when the parameter L is 1.25D (D is the fan diameter), pressure rise and comprehensive influence coefficients reach peak values of 20.090 Pa and 0.886, respectively. As well as the parameter H between 1.20 m and 1.25 m, the diffusion of the vertical wind field velocity is continuously reduced due to the constraint of the tunnel lining on Section BB of the tunnel fan’s symmetry axis, and the interference of the tunnel lining on the stable flow state of the fan’s outlet airflow is relatively small. Moreover, parameter T has a relatively low sensitivity impact on the increase in pressure and the variation of the influence coefficient. When the parameter T is within the range of 50 m to 100 m, the airflow at the entrance of the tunnel is smoothly connected with the airflow at the suction section of the fan. Additionally, the pressure rise and the influence coefficient increase by the parameter T. Both the fan’s pressure rise and the influence coefficient reach their maximum values when the parameter T is 100 m. Furthermore, in the case of two-fan groups, the gas is fully mixed in the tunnel when the parameter S is 150 m, and the fan pressure rise and the influence coefficient increase as well as parameter S. The gas between the two sets of fans has been fully mixed in the parameter S at 175 m, and the pressure rise and the coefficient influence reach their maximum values of 40.231 Pa and 0.887, respectively. In light of these findings, the following optimal parameters ranges are recommended for similar tunnel ventilation designs: parameter L is 1.25D for two jet fans within a single group, parameter H is between 1.20 m and 1.25 m, parameter T is 100 m from the tunnel entrance, and parameter S is between 150 m and 175 m for two groups of fans.