Different types and amounts of steel fibers have varying effects on the improvement of concrete’s mechanical properties. In order to identify the most suitable steel fiber types for the practical production of prefabricated pavements and derive a formula to predict and evaluate the mechanical properties based on steel fiber volume fraction, this study conducted experimental research on the physical mechanical properties of concrete using the method of equal volume substitution of coarse aggregate. The influence of steel fiber type and volume fraction on the microstructure and failure mechanism of steel fiber reinforced concrete (SFRC) was analyzed through electron microscopy scanning. The mechanical properties of plain concrete were used as benchmark. The results showed that when the steel fiber volume fractions were 0.6% and 1.5%, the bending and split tensile strengths of milled steel fibers were 3.1% higher than those of hooked-end steel fibers and the compressive strength of SFRC was significantly increased by 13.5%. The comprehensive mechanical properties of wave-shaped steel fibers were inferior to the first two types. Considering the requirements of SFRC in engineering, milled steel fibers are more suitable to be concrete components. This is because the tangling property of the hooked-end steel fibers makes them difficult to be shaped. In contrast, the smooth surface of milled steel fibers exerts a smaller impact on the forming of specimen and they are more economical. The mechanical properties of SFRC improve as the volume fraction of steel fibers increases from 0% to 2%, but start to decline when the volume fraction exceeds 2%. A volume fraction of 0.6% for steel fibers is sufficient to meet the standard for bending and tensile strength in heavy-duty concrete pavements. Finally, the relationship expressions between the compressive strength, flexural strength, and split tensile strength of SFRC and the steel fiber volume fraction were obtained through fitting the experimental data using Origin software.
During the operational ventilation process of high-altitude helical tunnels, the installation method of jet fans is a key factor in determining the ventilation efficiency of the tunnel. In this study, the CFD numerical simulation method is adopted to establish three-dimensional ventilation models of helical tunnels with different curvature radii. Through orthogonal experiments, the effects of tunnel curvature radius on the characteristics of the air jet flow field, under the coupled influences of factors such as lateral spacing of jet fans, vertical height of fans, longitudinal spacing, and lateral offset, are investigated. The results show that when R = 500 m, 600 m, 700 m, and 800 m, the longitudinal spacing has the most significant impact on ventilation efficiency, followed by vertical height, with lateral offset and fan spacing having the least impact. The optimal spacing and vertical height of the fan groups remain consistent under different curvature radii, at 1.25D (fan diameter) and 15 cm, respectively. The optimal longitudinal spacing of the fan groups is 90 m, 90 m, 135 m, and 90 m, respectively. Shifting the fan groups 0.25 to 0.75 m towards the inner side of the tunnel helix (for R < 700 m) can optimize the flow field distribution within the tunnel. Finally, expressions for the relationship between the helical radius and the lateral offset and longitudinal spacing of the fan groups are established for the optimal installation parameters of fan spatial positions under different helical tunnel radii.
In tunnel operation ventilation systems, the arrangement of jet fans plays a decisive role in ensuring ventilation efficiency. Curved tunnels, due to their unique radius of curvature, exhibit significant differences in fan installation parameters and jet flow field distribution compared to traditional straight-line tunnels. In order to investigate the distinct characteristics, this research utilized computational fluid dynamics (CFD) simulation methods to analyze the ventilation performance of both an innovative, adjustable jet fan system and conventional jet fans within the context of curved tunnel configurations. The findings reveal that by adjusting the horizontal deflection angle of the novel jet fan, the flow field distribution can be effectively optimized, and the jet effect can be enhanced, thereby improving ventilation efficiency. Compared to traditional jet fans, the novel fan demonstrates a significantly greater capability in flow field optimization, especially when its horizontal deflection angle is adjusted, showing a trend where the jet effect initially increases and then decreases, with the longitudinal impact range being adjustable within a range of 5 m to 25 m.