In 2011, a working group of the Consultative Committee for Thermometry published their best estimates of the differences between the thermodynamic temperature T and its approximation (T90), the temperature according to the International Temperature Scale of 1990, ITS-90. These consensus estimates, in combination with measurements made in accordance with ITS-90, are an important alternative to primary thermometry for those requiring accurate measurements of thermodynamic temperature. Since 2011, there has been a change in the definition of the kelvin and significant improvements in primary thermometry. This paper updates the (T − T90) estimates by combining and analyzing the data used for the 2011 estimates and data from more recent primary thermometry. The results of the analysis are presented as a 12th-order polynomial representing the updated consensus values for the differences and a sixth-order polynomial for their uncertainty estimates.
7 May 2021 in Journal of the Korean Physical Society
We determined accurate values of ratios among the average molar masses MAr of 9 argon samples using two completely-independent techniques: (1) mass spectrometry and (2) measured ratios of acoustic resonance frequencies. The two techniques yielded mutually consistent ratios (RMS deviation of 0.16 × 10−6MAr from the expected correlation) for the 9 samples of highly-purified, commercially-purchased argon with values of MAr spanning a range of 2 × 10−6MAr. Among the 9 argon samples, two were traceable to recent, accurate, argon-based measurements of the Boltzmann constant kB using primary acoustic gas thermometers (AGT). Additionally we determined our absolute values of MAr traceable to two, completely-independent, isotopic-reference standards; one standard was prepared gravimetrically at KRISS in 2006; the other standard was isotopically-enriched 40Ar that was used during NIST's 1988 measurement of kB and was sent to NIM for this research. The absolute values of MAr determined using the KRISS standard have the relative standard uncertainty ur(MAr) = 0.70 × 10−6 (Uncertainties here are one standard uncertainty.); they agree with values of MAr determined at NIM using an AGT within the uncertainty of the comparison ur(MAr) = 0.93 × 10−6. If our measurements of MAr are accepted, the difference between two, recent, argon-based, AGT measurements of kB decreases from (2.77 ± 1.43) × 10−6kB to (0.16 ± 1.28) × 10−6kB. This decrease enables the calculation of a meaningful, weighted average value of kB with a uncertainty ur(kB) ≈ 0.6 × 10−6.
Main text: This is a report to the Consultative Committee for Thermometry (CCT) on the key comparison 9 of Standard Platinum Resistance Thermometer (SPRT) calibration on the International Temperature Scale of 1990 (ITS-90) [1] from 83.8058 K (the Ar triple point) to 692.677 K (the Zn freezing point). The comparison followed a collapsed star protocol, with each of the fourteen participating laboratories shipping two standard platinum resistance thermometers (SPRTs) as transfer standards to the pilot laboratory (National Institute of Standards and Technology, NIST) for a direct comparison of SPRT calibration at the National Metrology Institute (NMI) of origin to calibration at NIST. Measurements were taken at the participating laboratories before and after measurement at NIST to assess the effect of transportation on the transfer standards. The pooled results from all laboratories were combined to calculate a key comparison reference value (KCRV). This report includes the calculation of, and comparisons to, the KCRV as well as bilateral comparisons between labs. In addition, there is space devoted to analysis of the shifts in SPRT values following travel. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
In this study, we realized the triple point (TP) temperature of sulfur hexafluoride (SF 6 ) at the National Institute of Metrology (NIM), China. To this end, we designed an iso-thermal and immersion type apparatus with an open cell with a height of 18 cm, diameter of 5 cm, and a capacity of approximately 275 ml. The cell was designed with four thermometer wells for the simultaneous temperature measurements with four standard platinum resistance thermometers (SPRTs). The cell is connected with two buffer tanks that allow a sufficient amount of SF 6 to surround the thermometer wells during the solidification and melting processes to ensure stable temperature plateaus with long durations. An SF 6 sample with a purity of 99.9997%, which is the highest purity currently available, was supplied and analyzed from the Korea Research Institute of Standards and Science. The SF 6 TP temperature was determined using four long-stem SPRTs. The melting plateaus obtained had a duration longer than 15 h, and the TP temperature of SF 6 was determined to be 223.556 03(54) K ( k = 1). These results are consistent with those of previous studies and further indicate that the SF 6 TP is a good candidate to replace mercury TP, which is one of the fixed points defined in the International Temperature Scale of 1990, for the calibration of SPRTs.