Martina Oder

Dr. Martina Oder

University of Ljubljana, Ljubljana, Slovenia
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2016 in Ultrasonics Sonochemistry
Verified
Journal Article
Open access
MDMatevž Dular
Matevž Dular
TGTjaša Griessler-Bulc
Tjaša Griessler-Bulc
IGIon Gutierrez-Aguirre
Ion Gutierrez-Aguirre
EHEster Heath
Ester Heath
TKTina Kosjek
Tina Kosjek
BKBoris Kompare
Boris Kompare
The use of acoustic cavitation for water and wastewater treatment (cleaning) is a well known procedure. Yet, the use of hydrodynamic cavitation as a sole technique or in combination with other techniques such as ultrasound has only recently been suggested and employed. In the first part of this paper a general overview of techniques that employ hydrodynamic cavitation for cleaning of water and wastewater is presented. In the second part of the paper the focus is on our own most recent work using hydrodynamic cavitation for removal of pharmaceuticals (clofibric acid, ibuprofen, ketoprofen, naproxen, diclofenac, carbamazepine), toxic cyanobacteria (Microcystis aeruginosa), green microalgae (Chlorella vulgaris), bacteria (Legionella pneumophila) and viruses (Rotavirus) from water and wastewater. As will be shown, hydrodynamic cavitation, like acoustic, can manifest itself in many different forms each having its own distinctive properties and mechanisms. This was until now neglected, which eventually led to poor performance of the technique. We will show that a different type of hydrodynamic cavitation (different removal mechanism) is required for successful removal of different pollutants. The path to use hydrodynamic cavitation as a routine water cleaning method is still long, but recent results have already shown great potential for optimisation, which could lead to a low energy tool for water and wastewater cleaning.

1 January 2016 in Desalination and Water Treatment
Verified
Journal Article
Open access
AŠAndrej Šarc
Andrej Šarc
Martina OderMartina Oder
Martina Oder
MDMatevž Dular
Matevž Dular
The presence of Legionella pneumophila bacteria in engineered water systems can pose a significant health risk. Current prevention and outbreak treatments are cost and environmentally ineffective. Moreover they do not prevent rapid bacteria recolonization. Although cavitation was already suggested as a possible water treatment technique a systematic study has not yet been performed. In the present experimental campaign we set out to evaluate the efficiency of removal of L. pneumophila by three types of cavitation—the most commonly used acoustic cavitation, the aggressive developed hydrodynamic cavitation, and the supercavitation. We show that it is probably not the pressure peaks or the high local temperatures that cause the eradication of the bacteria, but the rapid pressure decrease which was initiated in supercavitating flow regime. Results of the study show promising ground for further optimization of a methodology for L. pneumophila removal by cavitation.

KPKaća Piletić
Kaća Piletić
BKBruno Kovač
Bruno Kovač
Marko PerčićMarko Perčić
Marko Perčić
JŽJure Žigon
Jure Žigon
DBDalibor Broznić
Dalibor Broznić
Ivana GobinIvana Gobin
Ivana Gobin
Klebsiella pneumoniae is an emerging multidrug-resistant pathogen that can contaminate hospital surfaces in the form of a biofilm which is hard to remove with standard disinfectants. Because of biofilm resistance to conservative disinfectants, the application of new disinfection technologies is becoming more frequent. Ozone gas has antimicrobial activity but there is lack of data on its action against K. pneumoniae biofilm. The aim of this study was to investigate the effects and mechanisms of action of gaseous ozone on the OXA-48-procuding K. pneumoniae biofilm. A 24 h biofilm of K. pneumoniae formed on ceramic tiles was subsequently exposed to different concentrations of ozone during one and two hours to determine the optimal ozone concentration. Afterwards, the total bacteria count, total biomass and oxidative stress levels were monitored. A total of 25 ppm of gaseous ozone was determined to be optimal ozone concentration and caused reduction in total bacteria number in all strains of K. pneumoniae for 2.0 log10 CFU/cm2, followed by reduction in total biomass up to 88.15%. Reactive oxygen species levels significantly increased after the ozone treatment at 182% for the representative K. pneumoniae NCTC 13442 strain. Ozone gas in the concentration of 25 ppm caused significant biofilm reduction but did not completely eradicate the K. pneumoniae biofilm formed on ceramics. In conclusion, ozone gas has great potential to be used as an additional hygiene measure in joint combat against biofilm in hospital environments.

13 October 2014 in International Journal of Environmental Health Research
Verified
Journal Article
Closed access
Martina OderMartina Oder
Martina Oder
BKBoris Kompare
Boris Kompare
KBKlemen Bohinc
Klemen Bohinc
KTKarmen Godič Torkar
Karmen Godič Torkar
The adhesion of bacterial cells to various surfaces is based on physical and chemical interactions between the micro-organisms and the surfaces. The main purpose of this research is to determine the effect of material roughness and incubation temperature on the adhesion of bacteria. To determine the adhesion of the bacterial strain of Legionella pneumophila ATCC 33153 to the glass coupons, a spectrophotometric method of measuring the optical density of crystal violet dye that is released from pre-stained bacterial cells attached to the test surface was used. The intensity of adhesion is in positive correlation to the increase in surface roughness (p < 0.05). The adhesion is the greatest at an optimal temperature of 36 °C, whereas the temperature of 15 °C has a bacteriostatic effect and the temperature of 55 °C a bactericidal effect.

6 December 2021 in Soft Matter
Verified
Journal Article
Closed access
PDF file
JJJasmina Jukić
Jasmina Jukić
DKDavor Kovacevic
Davor Kovacevic
NCNikola Cindro
Nikola Cindro
Rok FinkRok Fink
Rok Fink
Martina OderMartina Oder
Martina Oder
Josip PozarJosip Pozar
Josip Pozar
The study was carried out with the aim of establishing how the outcomes of polyelectrolyte multilayer formation can be predicted on the basis of the results of complexation studies in solution and vice versa .

5 September 2022 in Processes
Verified
Journal Article
Open access
PDF file
KPKaća Piletić
Kaća Piletić
BKBruno Kovač
Bruno Kovač
MPMatej Planinić
Matej Planinić
VVVanja Vasiljev
Vanja Vasiljev
Irena Brčić KaračonjiIrena Brčić Karačonji
Irena Brčić Karačonji
Martina OderMartina Oder
Martina Oder
Acinetobacter baumannii is a prominent emerging pathogen responsible for a variety of hospital-acquired infections. It can contaminate inanimate surfaces and survive in harsh environmental conditions for prolonged periods of time in the form of biofilm. Biofilm is difficult to remove with only one method of disinfection, so combined disinfection methods and biocidal active substances are needed for biofilm eradication. Additionally, having in mind ecological demands, legislators are more prone using fewer toxic substances for disinfection that produce less solid waste and hazardous disinfection byproducts. Gaseous ozone and citric acid are natural biocidal compounds, and the purpose of this study was to determine their combined biocidal effects on A. baumannii biofilm formed on ceramics and polystyrene. Twenty-four-hour A. baumannii biofilm formed on ceramic tiles and polystyrene was exposed to different combinations of disinfection protocols with 25 ppm of gaseous ozone for 1 h exposure time and 15% citric acid for 10 min exposure. The total number of bacteria was counted afterwards and expressed as CFU/cm2. The determined disinfection protocols of A. baumannii biofilm with combined citric acid and gaseous ozone caused reduction of 2.8 to 5.89 log10 CFU (99.99% inhibition rate) of total viable bacteria for each method, with the citric acid–ozone–citric acid disinfection protocol being most successful in eradication of viable bacteria on both ceramics and polystyrene. In conclusion, gaseous ozone and citric acid showed good combined biocidal effects on A. baumannii biofilm and successfully reduced early A. baumannii biofilm from ceramic and polystyrene surfaces. The given combination of active substances can be a good option for eco-friendly disinfection of hospital inanimate surfaces from A. baumannii biofilm contamination with prior mechanical cleaning.