Manual material handling tasks in industry cause work-related musculoskeletal disorders. Exoskeletons are being introduced to reduce the risk of musculoskeletal injuries. This study investigated the effect of using a passive lumbar exoskeleton in terms of moderate ergonomic risk. Eight participants were monitored by electromyogram (EMG) and motion capture (MoCap) while performing tasks with and without the lumbar exoskeleton. The results showed a significant reduction in the root mean square (VRMS) for all muscles tracked: erector spinae (), semitendinosus (), gluteus (), and quadriceps (). The classic fatigue parameters showed a significant reduction in the case of the semitendinosus: zero-crossing rate, mean frequency, and median frequency. In addition, the logarithm of the normalized Dimitrov’s index showed reductions of 11.5, 8, and 14% in erector spinae, semitendinosus, and gluteus, respectively. The calculation of range of motion in the relevant joints demonstrated significant differences, but in almost all cases, the differences were smaller than . The findings of the study indicate that the passive exoskeleton reduces muscle activity and introduces some changes of strategies for motion. Thus, EMG and MoCap appear to be appropriate measurements for designing an exoskeleton assessment procedure.
A study is made to correlate the electrical and mechanical activity of the smooth muscle of the small bowel. Bioelectrical signal recording from the intestinal serosa (electroenterogram) comprises a slow wave (SW) and spike burst (SB), though only the latter reflects intestinal pressure. The electroenterogram and smooth muscle pressure are simultaneously recorded in the canine small bowel. Spectral and time series analysis of the electroenterogram are performed to establish those electrical parameters that best reflect intestinal pressure. The results reveal an underlying correlation between the estimated parameters of electrical activity and smooth muscle pressure. In addition, parameters derived from the spectral techniques were closely correlated to pressure events in the intestine, even more so than the variables directly acquired from the classical time domain analyses. Specifically, spectral energy above 2 Hz and mean frequency (both calculated from the biosignal periodogram), are parameters that identify intestinal pressure. The extrapolation of these spectral parameters to long time periods could serve to define a motility index (MI) from electrical gut activity. In this context, electroenterogram recording and analysis can contribute to solve problems inherent to manometric recording, though the need for surgical intervention restricts electrical methods to experimental or surgical studies.
Electrohysterography (EHG) has emerged as an alternative technique to predict preterm labor, which still remains a challenge for the scientific-technical community. Based on EHG parameters, complex classification algorithms involving non-linear transformation of the input features, which clinicians found difficult to interpret, were generally used to predict preterm labor. We proposed to use genetic algorithm to identify the optimum feature subset to predict preterm labor using simple classification algorithms. A total of 203 parameters from 326 multichannel EHG recordings and obstetric data were used as input features. We designed and validated 3 base classifiers based on k-nearest neighbors, linear discriminant analysis and logistic regression, achieving F1-score of 84.63 ± 2.76%, 89.34 ± 3.5% and 86.87 ± 4.53%, respectively, for incoming new data. The results reveal that temporal, spectral and non-linear EHG parameters computed in different bandwidths from multichannel recordings provide complementary information on preterm labor prediction. We also developed an ensemble classifier that not only outperformed base classifiers but also reduced their variability, achieving an F1-score of 92.04 ± 2.97%, which is comparable with those obtained using complex classifiers. Our results suggest the feasibility of developing a preterm labor prediction system with high generalization capacity using simple easy-to-interpret classification algorithms to assist in transferring the EHG technique to clinical practice.
5 July 2024 in Computer Methods and Programs in Biomedicine
Preterm delivery is an important factor in the disease burden of the newborn and infants worldwide. Electrohysterography (EHG) has become a promising technique for predicting this condition, thanks to its high degree of sensitivity. Despite the technological progress made in predicting preterm labor, its use in clinical practice is still limited, one of the main barriers being the lack of tools for automatic signal processing without expert supervision, i.e. automatic screening of motion and respiratory artifacts in EHG records. Our main objective was thus to design and validate an automatic system of segmenting and screening the physiological segments of uterine origin in EHG records for robust characterization of uterine myoelectric activity, predicting preterm labor and help to promote the transferability of the EHG technique to clinical practice. For this, we combined 300 EHG recordings from the TPEHG DS database and 69 EHG recordings from our own database (Ci2B-La Fe) of women with singleton gestations. This dataset was used to train and evaluate U-Net, U-Net++, and U-Net 3+ for semantic segmentation of the physiological and artifacted segments of EHG signals. The model's predictions were then fine-tuned by post-processing. U-Net 3+ outperformed the other models, achieving an area under the ROC curve of 91.4 % and an average precision of 96.4 % in detecting physiological activity. Thresholds from 0.6 to 0.8 achieved precision from 93.7 % to 97.4 % and specificity from 81.7 % to 94.5 %, detecting high-quality physiological segments while maintaining a trade-off between recall and specificity. Post-processing improved the model's adaptability by fine-tuning both the physiological and corrupted segments, ensuring accurate artifact detection while maintaining physiological segment integrity in EHG signals. As automatic segmentation proved to be as effective as double-blind manual segmentation in predicting preterm labor, this automatic segmentation tool fills a crucial gap in the existing preterm delivery prediction system workflow by eliminating the need for double-blind segmentation by experts and facilitates the practical clinical use of EHG. This work potentially contributes to the early detection of authentic preterm labor women and will allow clinicians to design individual patient strategies for maternal health surveillance systems and predict adverse pregnancy outcomes.
Approximately 25 % of diabetic patients develop diabetic foot ulcers (DFUs), significantly increasing morbidity, mortality, and healthcare costs. Effective control and prevention are crucial. This study aims to identify easily measurable parameters for predicting DFU risk by assessing the correlation between Phase Angle (PA) and the Triglyceride-Glucose (TyG) index with DFU risk. A comparative case-control study was conducted at the General Hospital of Elche from March to June 2023 with 70 participants (33 with diabetes, 37 without). Cases had diabetes for over five years and a diabetic foot risk grade of 0, 1, or 2 (IWGDF 2019). Exclusion criteria included inability to walk, prior use of orthoses, and severe complications like edema or wounds. Predictive variables were PA, TyG index, body composition, and biochemical markers. Statistical analyses included Pearson/Spearman tests for correlations, Student's t-test/Mann-Whitney test for group comparisons, and ANOVA/Kruskal-Wallis tests for normally and non-normally distributed variables. PAand TyG index were strongly linked to diabetic foot risk, supporting their potential as biomarkers. Significant relationships with other relevant biomarkers were also confirmed. PA and TyG index are valuable, easily measurable biomarkers for assessing diabetic foot risk, and can be monitored in primary care settings. Implementing these biomarkers in routine practice could enhance the management of diabetic complications, particularly in resource-limited settings, by enabling early detection and intervention, thus improving patient outcomes and reducing the burden of advanced complications.
Diabetic peripheral neuropathy (DPN) is a prevalent complication of chronic diabetes mellitus and has a significant impact on quality of life. DPN typically manifests itself as a symmetrical, length-dependent sensorimotor polyneuropathy with severe effects on gait. Surface electromyography (sEMG) is a valuable low-cost tool for assessing muscle activation patterns and precise identification of abnormalities. For the present study, we used information theory methods, such as cross-correlation (CC), normalized mutual information (NMI), conditional granger causality (CG-Causality), and transfer entropy (TE), to evaluate muscle network connectivity in three population groups: 33 controls (healthy volunteers, CT), 10 diabetic patients with a low risk of DPN (LW), and 17 moderate/high risk patients (MH). The results obtained indicated significant alterations in the intermuscular coupling mechanisms due to diabetes and DPN, with the TE group showing the best performance in detecting differences. The data revealed a significant increase in information transfer and muscle connectivity in the LW group over the CT group, while the MH group obtained significantly lower values for these metrics than the other two groups. These findings highlight the sEMG coupling metrics’ potential to reveal neuromuscular mechanisms that could aid the development of targeted rehabilitation strategies and help monitor DPN patients.