Dongxu Hou

Dr. Dongxu Hou


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 June 2025 in Buildings
Verified
Journal Article
Open access
PDF file
YSYuan yuan Sun
Yuan yuan Sun
DHDongxu Hou
Dongxu Hou
石石石岩彪 石
石岩彪 石
YSYamei Sun
Yamei Sun
CXChi Xv
Chi Xv
YWYunlin Wang
Yunlin Wang
With the advancement of urbanization, recycled aggregate concrete derived from construction waste has received increasing research attention. This study primarily focuses on a novel method to enhance the mechanical properties of recycled aggregate concrete derived from brick–concrete waste by mixing short-cut BFRP fibers. A series of experimental tests, including an axial compression test, a splitting tensile test, and a bending test, were conducted on specimens of RBCAC (recycled brick–concrete aggregate concrete) with different brick–concrete ratios and BFRP fiber contents. The effects of the brick–concrete ratio and BFRP content on various mechanical properties were systematically investigated. The results indicate that the brick–concrete ratio significantly affects the mechanical properties of RBCAC. The compressive strength decreased by approximately 2.0–4.7% as the brick-to-aggregate ratio increased from 0.25 to 4, with the peak strength (34.3 MPa) occurring at a ratio of 0.67. In addition, a strong linear relationship was observed between the compressive strength and other mechanical properties of BFRP-RBCAC. Based on the experimental data, the existing constitutive model for recycled concrete was modified by introducing a brick–concrete ratio correction factor and a fiber reinforcement factor. The proposed compression constitutive model is suitable for recycled brick–concrete aggregate concrete incorporating hybrid BFRP fibers.

1 January 2014 in Mathematical Problems in Engineering
Verified
Journal Article
Open access
PDF file
DHDongxu Hou
Dongxu Hou
JPJianyun Pan
Jianyun Pan
XFXinglang Fan
Xinglang Fan
ZWZhimin Wu
Zhimin Wu
PMProsper Marindiko
Prosper Marindiko
Deficiency of the concrete strength in some regions of reinforced concrete (RC) columns in practice may weaken the seismic behaviors of columns. Its effects on RC columns should be well understood. This paper aims to investigate the influences of deteriorated segment on the seismic behaviors of partially deteriorated RC columns and attempts to recover the seismic behaviors of partially deteriorated columns with Carbon Fiber Reinforced Polymer (CFRP) composites. A finite element analysis was carried out to simulate the seismic behaviors of CFRP‐confined partially deteriorated RC columns. The numerical results were verified by the laboratory tests of six specimens. Based on the finite element results, the failure location of partially deteriorated columns in an earthquake was predicted, and the effectiveness of CFRP retrofitted on partially deteriorated columns was evaluated.

3 February 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
DHDongxu Hou
Dongxu Hou
THTieming Hu
Tieming Hu
GZGuanhua Zhang
Guanhua Zhang
Super-span, reinforced concrete, T-shaped cross-section beams (T-beams) with a service life of more than 30 years are widely used in highway bridges in China. Most of these beams have been retrofitted with glass fiber-reinforced plastic (GFRP) to prevent performance degradation. However, the actual shear performance, ultimate state, and failure mechanism of the existing retrofitted super-span concrete T-beams are currently unclear for many inextricable problems. To fill these gaps, in this study, one super-span concrete T-beam, in service for 31 years and retrofitted with GFRP, was extracted from a highway bridge to conduct shear experimentation in a structural laboratory. To assess the particularity of the specimen, finite element analysis was also conducted using ABAQUS software as a supplement to the shear tests. The failure procedure of the specimen was investigated, and the influence of the loading mode on the shear performance of a super-long and old T-beam was also studied. It is concluded that the failure of the super-span T-beam begins with small cracks at the bottom of the mid-span, rather than a loading point.

2 August 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
DHDongxu Hou
Dongxu Hou
THTieming Hu
Tieming Hu
GZGuanhua Zhang
Guanhua Zhang
BCBoqi Chu
Boqi Chu
JZJing Zhu
Jing Zhu
XYXingdong Yang
Xingdong Yang
Super-span (20 m) non-prestressed T-section reinforced concrete beams have been in service for more than 30 years and are common in Chinese highway bridges. However, the actual performance of these super-span T-section reinforced concrete (RC) beams that have been reinforced with FRP, including their process of failure from a service state to a failure state, has not been determined. In this study, original RC T-beams, with a 20 m span and retrofitted with FRP, were taken from a highway bridge. Their flexural performance was detected via experiments in a laboratory. The experiments revealed that the sectional strain distribution is more non-uniform. The mid-span ribs clearly play a role in strengthening the section and the bearing reservation was studied based on a subsequent sectional analysis. It became clear that the load-bearing reservation of an old super-span T-beam changes during the entire life of the specimen; not only because of the depression of the resistant capacity and the reinforced measure, but also due to the updates to load codes.

10 July 2025 in Buildings
Verified
Journal Article
Open access
PDF file
YSYuan yuan Sun
Yuan yuan Sun
DHDongxu Hou
Dongxu Hou
石石石岩彪 石
石岩彪 石
YSYamei Sun
Yamei Sun
FMFancheng Meng
Fancheng Meng
DCDong Chen
Dong Chen
Recycled concrete is widely recognized as favorable for environmental protection and sustainable development. However, recycled concrete, especially containing abandoned brick aggregate, is rarely used in main structural members due to its inherent defects. Concrete-filled double steel tube columns (CFDSTCs), consisting of an outer and an inner steel tube with concrete filling the entire section, are effective in load bearing and deformation resistance. The structural application of abandoned brick aggregate, resulting from urbanization renewal, might be widened through CFDSTCs. This paper presents an experimental and analytical study aiming to investigate the axial compressive behavior of recycled-brick-aggregate-concrete-filled double steel tube columns (RBCDSTs). A total of six specimens were tested under concentric compression, including five RBCDSTs and one concrete-filled single steel tube column. The varied parameters included the replacement ratios (0% and 25%) of brick aggregate and the thickness ratio of the inner and outer steel tubes (0.75, 1, and 1.25). Theoretical analysis was also carried out. A new constitutive model of RBCDST was proposed and used in finite element analysis. The investigation indicated that, under the current conditions, the presence of the inner steel tube only increased the strength by 0.14%. When the inner and outer diameter ratio is 0.73, using a 25% replacement rate of bricks in the entire cross-section or only in the ring area of the cross-section will result in 21.1% and 10.1% strength decreases, respectively. For every 0.6% increase in the diameter-to-thickness ratio of the outer tube, the strength of RBCDST increases 16.3% on average.

1 January 2013 in International Journal of Engineering and Technology
Verified
Journal Article
Closed access
ZWZ. M. Wu
Z. M. Wu
DHDongxu Hou
Dongxu Hou
Wei (David) DongWei (David) Dong
Wei (David) Dong