Composite piles have emerged as a popular alternative to conventional piling materials for deep foundations and have gained significant traction as a specific type of pile due to their potential to mitigate durability issues often associated with standard piling materials. A new type of composite piles can improve structural behavior and extend service life. This research uses an inclusive review methodology to evaluate the geotechnical and structural behaviors of fiber-reinforced polymer (FRP) composite piles. Scopus was utilized to address the relevant keywords and state-of-the-art documents, and VSOviewer software was adopted to spot recurring patterns in the data using scientometric maps. Low-stiffness composite materials are a concern, according to the research work. Thus, researchers are working on confined concrete-filled FRP piles to improve the structural and geotechnical properties used in various load-bearing conditions. However, more research is required to comprehensively understand the behaviors of the studied types of composite piles. Indeed, there is a need for large-scale lab and field studies to determine how axial and lateral loads influence composite piles. This could help create guidelines for constructing the reviewed types of composite piles.
2 January 2025 in Geotechnical and Geological Engineering
Recent advancements in foundation engineering have introduced composite piles, specifically the Confined Concrete-Filled Aluminum Tube (CCFAT) pile system, which can effectively support both vertical and lateral loads. However, the behavior of composite piles under combined loading conditions remains largely unexplored. This research investigates the performance of CCFAT pile groups installed in loose sand and subjected to combined loads. Experimental studies focused on 1 × 2 and 2 × 2 CCFAT configurations with varying slenderness ratios (Lm/d) of 10, 15, and 20. These experiments were used to validate Finite Element (FE) models. Numerical simulations were then conducted for new configurations, including 2 × 3 and 3 × 3 CCFAT piles, to gather additional performance data. Results indicated that the ultimate vertical capacity of the CCFAT pile groups increased with the Lm/d ratio. Under combined loading, the ultimate lateral capacity also improved with higher vertical loads for a given Lm/d ratio. The laboratory findings showed a near-linear relationship between both ultimate vertical and lateral capacities and the Lm/d ratio. Failure mechanisms identified through numerical simulations revealed that CCFAT pile groups experienced punching shear failure, indicative of confined deep flow behavior. Under specific vertical loads, lateral loading resulted in soil compression on the right and tension on the left, causing heave and depression zones, significant soil yielding, and wedge formations. Sensitivity analyses highlighted that, for pure lateral loads, the internal friction angle and Young’s modulus significantly affect CCFAT pile group behavior, while under vertical loads at 80% of ultimate vertical load (Puv), the internal friction and dilatancy angles have a greater impact on lateral capacity than other parameters. Based on these findings, new expressions were proposed to calculate the ultimate lateral load (Pulv) for CCFAT pile groups under combined loading conditions, integrating the identified influencing factors.