Aims: To evaluate the impact of the COVID-19 pandemic on patient admissions to Italian cardiac care units (CCUs). Methods and Results: We conducted a multicentre, observational, nationwide survey to collect data on admissions for acute myocardial infarction (AMI) at Italian CCUs throughout a 1 week period during the COVID-19 outbreak, compared with the equivalent week in 2019. We observed a 48.4% reduction in admissions for AMI compared with the equivalent week in 2019 (P < 0.001). The reduction was significant for both ST-segment elevation myocardial infarction [STEMI; 26.5%, 95% confidence interval (CI) 21.7–32.3; P = 0.009] and non-STEMI (NSTEMI; 65.1%, 95% CI 60.3–70.3; P < 0.001). Among STEMIs, the reduction was higher for women (41.2%; P = 0.011) than men (17.8%; P = 0.191). A similar reduction in AMI admissions was registered in North Italy (52.1%), Central Italy (59.3%), and South Italy (52.1%). The STEMI case fatality rate during the pandemic was substantially increased compared with 2019 [risk ratio (RR) = 3.3, 95% CI 1.7–6.6; P < 0.001]. A parallel increase in complications was also registered (RR = 1.8, 95% CI 1.1–2.8; P = 0.009). Conclusion: Admissions for AMI were significantly reduced during the COVID-19 pandemic across Italy, with a parallel increase in fatality and complication rates. This constitutes a serious social issue, demanding attention by the scientific and healthcare communities and public regulatory agencies.
Aims: We aimed at investigating the feasibility and outcome of Micra implant in patients who have previously undergone transvenous lead extraction (TLE), in comparison to naïve patients implanted with the same device. Methods and results: Eighty-three patients (65 males, 78.31%; 77.27 ± 9.96 years) underwent Micra implant at our centre. The entire cohort was divided between ‘post-extraction’ (Group 1) and naïve patients (Group 2). In 23 of 83 patients (20 males, 86.96%; 73.83 ± 10.29 years), Micra was implanted after TLE. Indication to TLE was an infection in 15 patients (65.21%), leads malfunction in four (17.39%), superior vena cava syndrome in three (13.05%), and severe tricuspid regurgitation in one case (4.35%). The implant procedure was successful in all patients and no device-related events occurred at follow-up (median: 18 months; interquartile range: 1–24). No differences were observed between groups in fluoroscopy time (13.88 ± 10.98 min vs. 13.15 ± 6.64 min, P = 0.45), single device delivery (Group 1 vs. Group 2: 69.56% vs. 55%, P = 0.22), electrical performance at implant and at 12-month follow-up (Group 1 vs. Group 2: pacing threshold 0.48 ± 0.05 V/0.24 ms vs. 0.56 ± 0.25 V/0.24 ms, P = 0.70; impedance 640 ± 148.83 Ohm vs. 583.43 ± 99.7 Ohm, P = 0.27; and R wave amplitude 10.33 ± 2.88 mV vs. 12.62 ± 5.31 mV, P = 0.40). A non-apical site of implant was achievable in the majority of cases (72.3%) without differences among groups (78.26% vs. 70%; P = 0.42). Conclusion: Micra implant is an effective and safe procedure in patients still requiring a ventricular pacing after TLE, with similar electrical performance and outcome compared with naïve patients at long-term follow-up.
25 July 2020 in Journal of Interventional Cardiac Electrophysiology
Introduction: Mitral valve prolapse (MVP) is a common clinical condition in the general population. A subgroup of patients with MVP may experience ventricular arrhythmias and sudden cardiac death (“arrhythmic mitral valve prolapse” [AMVP]) but how to stratify arrhythmic risk is still unclear. Our meta‐analysis aims to identify predictive factors for arrhythmic risk in patients with MVP.Methods: We systematically searched Medline, Cochrane, Journals@Ovid, Scopus electronic databases for studies published up to December 28, 2022 and comparing AMVP and nonarrhythmic mitral valve prolapse (NAMVP) for what concerns history, electrocardiographic, echocardiographic and cardiac magnetic resonance features. The effect size was estimated using a random‐effect model as odds ratio (OR) and mean difference (MD).Results: A total of 10 studies enrolling 1715 patients were included. Late gadolinium enhancement (LGE) (OR: 16.67; p = .005), T‐wave inversion (TWI) (OR: 2.63; p < .0001), bileaflet MVP (OR: 1.92; p < .0001) and mitral anulus disjunction (MAD) (OR: 2.60; p < .0001) were more represented among patients with AMVP than in NAMVP. Patients with AMVP were shown to have longer anterior mitral leaflet (AML) (MD: 2.63 mm; p < .0001), posterior mitral leaflet (MD: 2.96 mm; p < .0001), thicker AML (MD: 0.49 mm; p < .0001), longer MAD length (MD: 1.24 mm; p < .0001) and higher amount of LGE (MD: 1.41%; p < .0001) than NAMVP. AMVP showed increased mechanical dispersion (MD: 8.04 ms; 95% confidence interval: 5.13–10.96; p < .0001) compared with NAMVP.Conclusions: Our meta‐analysis proved that LGE, TWI, bileaflet MVP, and MAD are predictive factors for arrhythmic risk in MVP patients.
13 May 2020 in Journal of Interventional Cardiac Electrophysiology
Aims: Pre-procedural imaging can facilitate scar-related ventricular tachycardia (VT) ablation, although only limited data have been reported. This prospective registry aimed to analyse procedural data and outcomes in a multi-centre setting of a pre-defined VT ablation strategy facilitated by the integration of pre-procedural imaging into the navigation system. Methods and results: Consecutive patients referred for scar-related left-sided VT ablation were prospectively enrolled at five European tertiary hospitals. Pre-procedural cardiac magnetic resonance (CMR)–derived scar maps and/or multi-detector computed tomography (MDCT)–derived wall thinning maps of the left ventricle (LV) were obtained and integrated into the navigation system. An endocardial or endoepicardial approach was chosen based on the scar distribution at pre-procedural imaging. The decision of performing a detailed electro-anatomical map (EAM) of the LV (image-aided) or to using the pre-procedural imaging for guiding the ablation without obtaining an EAM (image-guided) was left to the physician’s discretion. One hundred and seventy-one patients (71% with ischaemic cardiomyopathy) were included. Cardiac magnetic resonance was integrated in 159 (93%), MDCT in 113 (66%), and both in 101 (59%) procedures. Procedure-related complications occurred in 9 (5%) patients. At a mean follow-up of 18 ± 19 months, the overall survival and VT recurrence-free survival were 91 and 74.4%, respectively. There were no significant differences in long-term ablation outcomes based on the type of cardiomyopathy (P = 0.88) or the pre-procedural imaging modality employed (P = 0.33). An image-guided approach appears feasible, safe, and faster, with reduced procedure, radiofrequency, and fluoroscopy times, without compromising efficacy. Conclusion: In a large multi-centre prospective cohort, VT ablation facilitated by pre-procedural imaging is associated with favourable long-term outcomes.