Giampaolo Vetta

Dr. Giampaolo Vetta

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 April 2023 in Pacing and Clinical Electrophysiology
Verified
Journal Article
Closed access
APAntonio Parlavecchio
Antonio Parlavecchio
GVGiampaolo Vetta
Giampaolo Vetta
RCRodolfo Caminiti
Rodolfo Caminiti
GCGiovanni Coluccia
Giovanni Coluccia
MMMichele Magnocavallo
Michele Magnocavallo
PPPietro Palmisano
Pietro Palmisano

1 September 2024 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Closed access
DRDomenico Giovanni Della Rocca
Domenico Giovanni Della Rocca
MCMaría Cespón-Fernández
María Cespón-Fernández
AKAhmad Keelani
Ahmad Keelani
SRSanti Raffa
Santi Raffa
LPLuigi Pannone
Luigi Pannone
IEIvan Eltzov
Ivan Eltzov
BACKGROUND: Pulsed field ablation (PFA) is a novel technology for catheter-based atrial arrhythmia treatment. Evidence of its application for ventricular arrhythmia ablation is still limited. In this study, we describe the feasibility and efficacy of focal PFA for premature ventricular contraction (PVC) ablation. METHODS: A prospective cohort of 20 patients referred for PVC ablation at 2 centers was enrolled, regardless of the presence of structural heart disease, PVC morphology, or previous ablation attempts. All procedures were performed using the CENTAURI System in combination with contact force sensing catheters and 3-dimensional electroanatomical mapping systems. Energy output and the number of applications were left to the operator’s discretion. RESULTS: Eleven (55%) procedures were conducted under general anesthesia, 6 (30%) under deep sedation, and 3 (15%) under light sedation. Muscular contraction was observed in one case (5%). Median procedural and fluoroscopy times were 95.5 and 6.55 minutes, respectively. The median number of PFA applications was 8 with a median contact force of 10 g . A statistically significant (76%) reduction was observed in mean peak-to-peak bipolar electrogram voltage before and after ablation (0.707 versus 0.098 mV; P =0.008). Ventricular irritative firing was observed in 11 (55%) patients after PFA. The median follow-up was 120 days. Acute procedural success was achieved in 17 of 20 (85% [95% CI, 0.70–1]) patients. Two of the patients with procedural failure had late success with >80% clinical PVC burden suppression during follow-up, and 2 of 17 patients with acute success had late PVC recurrence, which accounts for a total of 17 of 20 (85% [95% CI, 0.70–1]) patients with chronic success. Transient ST-segment depression occurred in 1 patient, and the right bundle branch block was induced in 2 others (permanently only in one case). CONCLUSIONS: PVC ablation using a focal PFA is feasible, effective, and safe, with promising acute and long-term results in several ventricular locations. Irritative firing is frequently observed. Coronary evaluation should be considered when targeting the outflow tract.

28 December 2023 in EP Europace
Verified
Journal Article
Open access
PDF file
DRDomenico Giovanni. Della Rocca
Domenico Giovanni. Della Rocca
MMMichele Magnocavallo
Michele Magnocavallo
CGCarola Gianni
Carola Gianni
SMSanghamitra Mohanty
Sanghamitra Mohanty
AAAmin Al-Ahmad
Amin Al-Ahmad
ANAndrea Natale
Andrea Natale
Left atrial appendage (LAA) imaging is critical during percutaneous occlusion procedures. 3D-intracardiac echocardiography (ICE) features direct visualization of LAA from multiple cross-sectional planes at a time. We aimed at reporting procedural success of 3D-ICE-guided LAA occlusion and the correlation between pre-procedural transoesophageal echocardiography (TEE) and intraprocedural 3D-ICE for LAA sizing. Among 274 patients undergoing left atrial appendage occlusion (LAAO) with a Watchman FLX, periprocedural ICE guidance was achieved via a commercially available 2D-ICE catheter (220 patients) or a novel (NUVISION™) 3D-ICE one (54 patients). Primary endpoint was a composite of procedural success and LAA sealing at follow-up TEE. Secondary endpoint was a composite of periprocedural device recapture/resizing plus presence of leaks ≥ 3 mm at follow-up TEE. 3D-ICE measurements of maximum landing zone correlated highly with pre-procedural TEE reference values [Pearson’s: 0.94; P < 0.001; bias: −0.06 (−2.39, 2.27)]. The agreement between 3D-ICE-based device selection and final device size was 96.3% vs. 79.1% with 2D-ICE (P = 0.005). The incidence of the primary endpoint was 98.1% with 3D-ICE and 97.3% with 2D-ICE (P = 0.99). 2D-ICE patients had a trend towards a higher incidence of periprocedural device recapture/redeployment (31.5% vs. 44.5%; P = 0.09). The secondary endpoint occurred in 31.5% of 3D-ICE patients vs. 45.9% of 2D-ICE ones (P = 0.065). Intracardiac echocardiography-guided LAAO showed a very high success, with no major adverse events. A very high level of agreement for LAA sizing was found between pre-procedural TEE and periprocedural 3D-ICE. 3D-ICE performed significantly better than 2D-ICE for FLX size selection and may provide better guidance during device deployment.

1 January 2024 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Open access
Roberto MenèRoberto Menè
Roberto Menè
SBSerge Boveda
Serge Boveda
DRDomenico Giovanni. Della Rocca
Domenico Giovanni. Della Rocca
VSVasileios Sousonis
Vasileios Sousonis
GVGiampaolo Vetta
Giampaolo Vetta
SCStéphane Combes
Stéphane Combes

4 October 2023 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Closed access
AMAlvise Del Monte
Alvise Del Monte
MFMaría Cespón Fernández
María Cespón Fernández
GVGiampaolo Vetta
Giampaolo Vetta
DRDomenico Giovanni Della Rocca
Domenico Giovanni Della Rocca
LPLuigi Pannone
Luigi Pannone
Carlo de AsmundisCarlo de Asmundis
Carlo de Asmundis

23 November 2024 in EP Europace
Verified
Journal Article
Open access
PDF file
GVGiampaolo Vetta
Giampaolo Vetta
DRDomenico Giovanni. Della Rocca
Domenico Giovanni. Della Rocca
APAntonio Parlavecchio
Antonio Parlavecchio
MMMichele Magnocavallo
Michele Magnocavallo
ASAntonio Sorgente
Antonio Sorgente
GCGian Battista Chierchia
Gian Battista Chierchia
Pulsed field ablation (PFA) is an innovative technology recently adopted for the treatment of atrial fibrillation (AF). Preclinical and clinical studies have reported a remarkable safety profile, as a result of its tissue specific effect targeting cardiomyocytes and sparing adjacent tissues. Single-shot pentaspline system was the first PFA device to receive regulatory approval. We performed a meta-analysis to compare the efficacy and safety of PFA with the single-shot pentaspline system versus currently available 2nd/3rd/4th generation Cryoballoon technologies (CRYO). We systematically searched electronic databases for studies focusing on AF ablation employing the PFA single-shot pentaspline system or 2nd/3rd/4th generation CRYO technologies. The primary endpoints were acute procedural success assessed on a vein and patient basis. Safety endpoints included overall periprocedural complications and major periprocedural complications. We also compared procedural, fluoroscopy times, and freedom from atrial tachyarrhythmias (ATs) at follow-up (secondary endpoints). Twenty and 70 studies were included for PFA and CRYO, respectively. PFA demonstrated greater acute procedural success on a vein basis (99.9% vs 99.1%; p<0.001), as well as per patient (99.5% vs 98.4%; p<0.001). PFA yielded lower overall periprocedural complications (3.1% vs 5.6%; p<0.001), shorter procedural time (75.9 min vs 105.6 min; p<0.001) and fluoroscopy time (14.2 min vs 18.9 min; p<0.001) compared to CRYO. No differences were found for major periprocedural complications (1.2% vs 1.0%; p=0.46) and freedom from ATs at 1 year (82.3% vs 80.3%; Log-rank p= 0.61). PFA contributed to higher acute procedural success, and safety compared to CRYO. No statistically significant differences in AT recurrence at 1-year follow-up were observed.