Yan Yan

Dr. Yan Yan

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 June 2010 in International Journal of Hematology
Verified
Journal Article
Closed access
PDF file
RHRonghua Hu
Ronghua Hu
YYYan Yan
Yan Yan
QLQinghua Li
Qinghua Li
YLYani Lin
Yani Lin
WJWei-na Jin
Wei-na Jin
TPTianxiang Pang
Tianxiang Pang

7 December 2023 in Cells
Verified
Journal Article
Open access
PDF file
Tian LiuTian Liu
Tian Liu
LWLiam Wetzel
Liam Wetzel
ZZZexi Zhu
Zexi Zhu
PKPavan Kumaraguru
Pavan Kumaraguru
VGViraj Gorthi
Viraj Gorthi
DKDavid E Kang
David E Kang
Coiled-coil-helix-coiled-coil-helix domain-containing 10 (CHCHD10) is a nuclear-encoded mitochondrial protein which is primarily mutated in the spectrum of familial and sporadic amyotrophic lateral sclerosis (ALS)–frontotemporal dementia (FTD). Endogenous CHCHD10 levels decline in the brains of ALS–FTD patients, and the CHCHD10S59L mutation in Drosophila induces dominant toxicity together with PTEN-induced kinase 1 (PINK1), a protein critical for the induction of mitophagy. However, whether and how CHCHD10 variants regulate mitophagy flux in the mammalian brain is unknown. Here, we demonstrate through in vivo and in vitro models, as well as human FTD brain tissue, that ALS/FTD-linked CHCHD10 mutations (R15L and S59L) impair mitophagy flux and mitochondrial Parkin recruitment, whereas wild-type CHCHD10 (CHCHD10WT) normally enhances these measures. Specifically, we show that CHCHD10R15L and CHCHD10S59L mutations reduce PINK1 levels by increasing PARL activity, whereas CHCHD10WT produces the opposite results through its stronger interaction with PARL, suppressing its activity. Importantly, we also demonstrate that FTD brains with TAR DNA-binding protein-43 (TDP-43) pathology demonstrate disruption of the PARL–PINK1 pathway and that experimentally impairing mitophagy promotes TDP-43 aggregation. Thus, we provide herein new insights into the regulation of mitophagy and TDP-43 aggregation in the mammalian brain through the CHCHD10–PARL–PINK1 pathway.

12 February 2026 in American Journal of Gastroenterology
Verified
Journal Article
Closed access
KNKapil D. Nayar
Kapil D. Nayar
AYAbdelrahman Yakout
Abdelrahman Yakout
NBNader Bakheet
Nader Bakheet
PSPatrick Sanchez
Patrick Sanchez
OOOsayande Osagiede
Osayande Osagiede
VKVivek Kumbhari
Vivek Kumbhari
INTRODUCTION: Colonoscopies reduce colorectal cancer incidence and mortality, but challenges remain in detecting all precancerous lesions. Operator fatigue, technique variability, and subtle lesions can lead to missed adenomas, highlighting the need for tools that standardize detection quality. Computer-aided detection (CADe) systems use artificial intelligence to enhance lesion detection and improve screening colonoscopy quality. This study evaluates the impact of CADe on key quality and efficiency metrics in a clinical setting. METHODS: A single-center retrospective study at an academic tertiary center analyzed 4,028 colonoscopies from October 2022 to December 2023. The CADe system was used in 4 of 8 endoscopy suites, creating a CADe and control group. Propensity matching accounted for age, sex, indication, and physician. Primary outcomes included adenoma detection rate (ADR) and polyp detection rate (PDR). Adenomas per colonoscopy (APC) and polyps per colonoscopy (PPC) were also measured. Per-polyp analyses were performed as a tertiary outcome. RESULTS: ADR was significantly higher in the CADe group (38.6%) vs control (34.2%) (rate ratio [RR] = 1.127, P < 0.05). PDR was significantly higher in the CADe group (67.2%) vs control (59.4%) (RR = 1.130, P < 0.05). APC was significantly higher in the CADe group (M = 0.406, SD 0.637) vs control (M = 0.359, SD 0.599) (RR = 1.131, P < 0.05). PPC was significantly higher in the CADe group (M = 1.297, SD 1.188) vs control (M = 1.046, SD 1.002) (RR = 1.240, P < 0.05). The increase in polyp resection with CADe was driven predominantly by ≤5 mm lesions, with comparatively smaller differences for larger polyps. DISCUSSION: Implementing CADe in clinical practice significantly improved ADR, PDR, APC, and PPC. However, the increase in ADR seems inflated by the detection of polyps ≤5 mm, whose clinical significance in reducing colorectal cancer remains uncertain.

23 December 2024 in Livers
Verified
Journal Article
Open access
PDF file
YHYuting Huang
Yuting Huang
YWYichen Wang
Yichen Wang
YYYan Yan
Yan Yan
Samuel O AntwiSamuel O Antwi
Samuel O Antwi
DBDilhana S. Badurdeen
Dilhana S. Badurdeen
YLYang Liu
Yang Liu
Background: Metabolic dysfunction-associated steatotic liver disease (MASLD) has surged as a major cause of liver transplants in the United States. Existing studies have presented conflicting findings regarding the association between liver characteristics (specifically steatosis and fibrosis) and mortality. This study investigates the relationship between the controlled attenuation parameter (CAP) and liver stiffness measurement (LSM) via vibration-controlled transient elastography (VCTE) and all-cause mortality in MASLD patients. Methods: Using the NHANES 2017-2018 database, 3821 individuals representing the United States population with MASLD underwent VCTE for liver stiffness measurement. Exclusion criteria were applied, eliminating ineligible cases, incomplete examinations, underage individuals, and those with hepatitis B or C, along with significant alcohol consumption history. Cox proportional hazard models assessed the hazard ratio (HR) for all-cause mortality in CAP and LSM. Cox regression analysis with interaction terms was employed for deeper exploration. Results: The study unveiled a strong, independent correlation between LSM and all-cause mortality. However, the CAP failed to demonstrate a significant association with mortality in both univariate and adjusted analyses, contrary to recent findings. The analysis underscores the importance of accurately measuring liver stiffness via VCTE in predicting adverse outcomes in MASLD patients, emphasizing the pivotal role of fibrosis in assessing mortality risk. Conclusion: This study reaffirms the robust link between liver fibrosis (measured through VCTE) and mortality among MASLD individuals. The absence of a significant association between steatosis (indicated by CAP) and mortality challenges recent research, urging further comprehensive investigations with larger cohorts to delineate steatosis’ precise impact on MASLD-related mortality.

16 June 2022 in Gastroenterology
Verified
Journal Article
Closed access
KWKai Wang
Kai Wang
RMRaaj S. Mehta
Raaj S. Mehta
WMWenjie Ma
Wenjie Ma
LNLong H. Nguyen
Long H. Nguyen
DWDong Wang
Dong Wang
MSMingyang Song
Mingyang Song

24 June 2026 in Livers
Verified
Journal Article
Open access
PDF file
PTPaul Travers
Paul Travers
YWYichen Wang
Yichen Wang
YYYan Yan
Yan Yan
JZJiang Zou
Jiang Zou
NHNabanita Halder
Nabanita Halder
YHYuting Huang
Yuting Huang
Ex vivo liver perfusion (EVLP) sustains human or large animal livers outside the body under near-physiological conditions, enabling functional monitoring for lactate clearance, bile production, and oxygen consumption and allowing targeted therapeutic interventions. Originally developed to optimize donor grafts for transplantation, EVLP has evolved into a powerful translational research platform bridging preclinical discovery and early clinical translation. This review discusses EVLP as a platform for gene therapy, immunotherapy, pharmacology, and personalized medicine, with particular emphasis on gene- and immune-based interventions as mechanistically mature exemplars. We consolidate advances in pharmacological testing and toxicity modeling, viral and non-viral gene delivery, genome engineering, and immunomodulation using perfused livers. We further describe emerging applications, including autologous EVLP pathways for organ-confined therapy, ex vivo liver surgery, and bioengineering strategies such as biliary organoid repair, RNA interference, and mitochondrial transfer. We highlight how these applications align with a paradigm shift in biomedical research, including the NIH’s recent initiative to prioritize human-based experimental models over animal-only studies. By leveraging transplant-declined or surgically resected organs that would otherwise be unused, ex vivo perfusion bridges the gap between pre-clinical testing and clinical practice, enabling real-time evaluation of interventions in functional human tissue. We discuss both the scientific opportunities afforded by EVLP and the technical, biosafety, and ethical challenges that must be addressed to enable responsible clinical translation.