A modified single‐phase hybrid cascaded H bridge multilevel inverter with a minimum number of power electronic devices and isolated DC sources is presented in this study. It consists of two inverters (upper and lower) coupled in cascade. The lower inverter is capable of developing a multilevel output and switches at low frequency and another inverter develops two‐level output and switches at high frequency. In the proposed inverter, every additional power electronic switch in the lower inverter increases the level by four. This study also introduces a generalised hybrid modulation switching strategy, which gives arithmetical and logical expressions for switching the additional device for any required increase in levels. The voltage rating of the devices, conduction and switching loss of the proposed inverter are compared with the similarly setup topologies. The generalised hybrid modulation algorithm is simulated in MATLAB/Simulink and implemented in a SPATRAN 3A DSP board. Simulation and experimental results are presented for different loading conditions.
This paper presents the theoretical analysis, design and simulation of a single phase single stage boost dc-ac converter powered from PV array. The main attribute of the boost inverter topology is the fact that it generates an ac output voltage larger than the dc input one, depending on the instantaneous duty cycle. This paper proposes an accurate solar panel simulation to incorporate the temperature and irradiation dependence of panel voltage and current along with neural network based MPPT algorithm. This paper also analyses the performance of proportional and integral (PI) and sliding mode controllers (SMC) for the closed loop controlling of PV fed boost inverter.
21 December 2021 in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
Due to advancements in power electronics devices and the support of improvements on both the power supply and load sides, Distributed Energy (DG) is rapidly being connected to the grid in the form of AC/DC Hybrid Micro-Grid (HMG). The development will result in a substantial change in the network topology, new design problems for the micro-grid control unit, and new requirements for the simulation testing laboratory. The Bidirectional AC-DC converter (BAC) is necessary for hybrid microgrids to provide voltage stableness and power equilibrium between the AC and DC grids. To suppress the harmonic current control approach, an enhanced Fryze-Buchholz Depenbrock (FBD) current harmonic detection technique is integrated with droop control in this paper. This proposed system not only performs the power transformation but also minimizes harmonics. While considering non-linear load, the proposed system yields the control ability for regulating the converter to eliminate the harmonics of 74.41% in the grid current. While incorporating the HMG in the proposed system, the control strategy decreases 90.3% and 89.4% of reactive power in both linear and non-linear loads. The obtained simulation results are used to confirm the feasibility and effectiveness of the control scheme.
In this paper, a novel single-phase cascaded grid connected multilevel inverter (MLI) is proposed for feeding power to microgrid from renewable energy sources (RESs). The proposed inverter is capable of feeding power to microgrid with low total harmonic distortion (THD). The proposed inverter consists of two H bridge inverters connected in cascade, namely, upper and lower inverters. The upper inverter is fed from photovoltaic (PV) array through a DC–DC boost converter, whereas the lower inverter is fed from wind turbine (WT) coupled to permanent magnet synchronous generator (PMSG) through an uncontrolled rectifier and DC–DC boost converter. The upper inverter operates at high frequency, whereas the lower inverter operates at fundamental frequency. To extract maximum power from the WT and PV array, a sliding mode control based maximum power point tracker (MPPT) is used. The proposed inverter is connected to the single phase 230 V, 50 Hz grid, and the control algorithm is implemented in the SPARTAN 3A digital signal processor (DSP) board. The proposed inverter is simulated using matlab/simulink, and detailed experimental results are presented to show the efficacy of the proposed inverter under different environmental conditions.