To enable future deep space exploration, orbital refueling of spacecraft is essential. However, transferring liquid in a microgravity environment is a complex process dependent on various factors. One of the basic and critical tasks is to separate phases to allow the supply of gas-free liquid from one tank to another. For this purpose, a liquid acquisition device is essential. In this work, a screen channel liquid acquisition device was designed and used to investigate phase separation and liquid removal from an experiment tank in a microgravity environment. The experiments were performed using the drop tower facility at the University of Bremen, with HFE-7500 as the test liquid under isothermal conditions. This investigation explored the interdependent effects of various phenomena, including the reorientation of liquid in the tank, capillary rise between parallel plates, flow through screen pressure variation, and bubble point breakthrough. Under subcritical conditions, the SC-LAD was found to supply gas-free liquid at the outlet, as long as the pressure drop across the screen was lower than the bubble point threshold. At the critical point, the screen started to ingest bubbles, resulting in a sharp peak in the differential pressure signal. The wetted area of the screen was obtained by analyzing images captured with a high-speed camera and used to calculate the analytical pressure drop. The experimental results were compared with the analytical solution and discussed in detail.
The development of porous ceramic screens with high chemical stability, low density, and thermal conductivity can lead to promising screen channel liquid acquisition devices (SC-LADs) for propellant management under microgravity conditions in the future. Therefore, SiOC screens with aligned pores were fabricated via freeze-casting and applied as a SC-LAD. The pore window sizes and open porosity varied from 6 µm to 43 µm and 65% or 79%, depending on the freezing temperature or the solid loading, respectively. The pore window size distributions and bubble point tests indicate crack-free screens. On the one hand, SC-LADs with an open porosity of 79% removed gas-free liquid up to a volumetric flow rate of 4 mL s−1. On the other hand, SC-LADs with an open porosity of 65% were limited to 2 mL s−1 as the pressure drop across these screens was relatively higher. SC-LADs with the same open porosity but smaller pore window sizes showed a higher pressure drop across the screen and bubble ingestion at higher values of effective screen area when increasing the applied removal volumetric flow rate. The removed liquid from the SC-LADs was particle-free, thus representing a potential for applications in a harsh chemical environment or broad-range temperatures.