This paper discusses a non-destructive evaluation (NDE) technique for the detection of damage in composite aircraft structures following high energy wide area blunt impact (HEWABI) from ground service equipment (GSE), such as heavy cargo loaders and other heavy equipment. The test structures typically include skin, co-cured stringers, and C-frames that are bolt-connected onto the skin with shear ties. The inspection exploits the waveguide geometry of these structures by utilizing ultrasonic guided waves and a line scan approach. Both a contact prototype and a non-contact prototype were developed and tested on realistic test panels subjected to impact in the laboratory. The results are presented in terms of receiver operating characteristic curves that show excellent probability of detection with low false alarm rates for defects located in the panel skin and stringers.
Shear wave elastography (SWE) is an ultrasonic technique able to quantitatively assess the mechanical properties of tissues by combining acoustic radiation force and ultrafast imaging. While utilizing coherent plane wave compounding enhances echo and shear wave motion signal-to-noise ratio (SNR), it also reduces the effective pulse repetition frequency (PRFe), affecting the accuracy of the measurements of motion and, consequently, of material properties. It is important to maintain both high-motion SNR and PRFe, particularly for the characterization of (material and/or geometrical) dispersive tissues such as arteries. This work proposes a method for SWE measurements with high SNR, while maintaining a high PRFe, using conventional clinical ultrasound scanners. A time alignment process is applied after acquiring data from plane wave transmissions at different angles. The time alignment uses interpolation to obtain data points at higher frame rates, and the time-aligned data are compounded to increase the SNR. The method is used for SWE in tissue-mimicking phantoms of different stiffness and is compared with traditional plane wave compounding. Increases of 58% and 36% in spatial and temporal bandwidth compared with conventional plane wave compounding, respectively, can be achieved for SWE measurements of representative arterial stiffness values. Improvements in phase velocity accuracy and bandwidth in an arterial phantom are also described, to emphasize the beneficial advantage in dispersive cases.
Objective . Arterial dispersion ultrasound vibrometry (ADUV) relies on the use of guided waves in arterial geometries for shear wave elastography measurements. Both the generation of waves through the use of acoustic radiation force (ARF) and the techniques employed to infer the speed of the resulting wave motion affect the spectral content and accuracy of the measurement. In particular, the effects of the shape and location of the ARF beam in ADUV have not been widely studied. In this work, we investigated how such variations of the ARF beam affect the induced motion and the measurements in the dispersive modes that are excited. Approach. The study includes an experimental evaluation on an arterial phantom and an in vivo validation of the observed trends, observing the two walls of the waveguide, simultaneously, when subjected to variations in the ARF beam extension ( F / N ) and focus location. Main results. Relying on the theory of guided waves in cylindrical shells, the shape of the beam controls the selection and nature of the induced modes, while the location affects the measured dispersion curves (i.e. variation of phase velocity with frequency or wavenumber, multiple modes) across the waveguide walls. Significance. This investigation is important to understand the spectral content variations in ADUV measurements and to maximize inversion accuracy by tuning the ARF beam settings in clinical applications.
The nondestructive characterization and monitoring of defects in composite structures by ultrasonic guided waves are hindered by the complexity of the interaction. Efficient computational modeling of propagating ultrasonic guided waves in waveguides with discontinuities is necessary to properly tune inspections and correctly interpret the scattering behavior. This paper studies the influence of different defect types in composite plates on ultrasonic guided wave scattering. Employing a hybrid global–local method, the energy spectra of transmitted and reflected waves in defected composite plates are numerically analyzed over a broad frequency range. Through parametric analyses of defect dimensions and locations, the resulting trends of the effect of specific defect features on the scattering behavior, as well as the importance of observing scattering on a broad frequency range, are accurately computed and highlighted. The presented findings indicate the potential for effective defect characterization and monitoring.
9 February 2023 in Journal of Nondestructive Evaluation, Diagnostics and Prognostics of Engineering Systems
As structures increase in complexity, in the use of high-performing materials and designs, their health assessment becomes increasingly challenging. Ultrasonic guided waves (UGWs) have shown to be very promising in the inspection of large (i.e. aerospace components) attenuating (i.e. composite materials) structures and have been successfully employed for damage detection in a variety of fields. The intrinsic complex nature of UGWs, due to their dispersive behavior, combined with the structural complexity of the applications, though, makes the interpretation of UGW inspections very challenging. Numerical simulations of UGW propagation become crucial to this end and have been addressed with fully numerical, semi-analytical and hybrid approaches. The capability of predicting UGW scattering can inform experimental testing in optimizing the sensitivity of UGW inspections to specific waveguides and defects, and in interpreting the acquired data for the non-destructive identification and quantification of damages. In this work, an improved computational tool for UGW scattering predictions is presented. The approach relies on the Global-Local method and leverages the efficiency of the semi-analytical finite element (SAFE) method and the parallelized implementation of the coupled solution. 2D applications of the Global-Local approach for UGW scattering predictions in composite structures over a wide range of frequencies will be presented, together with the demonstration of the improved computational performance. The computational efficiency promises feasible and reliable UGWs predictions in multi-layered complex assemblies and different damage scenarios, and enables virtual UGWs inspections and future integration in NDE testing.