Contact mechanics is the study of the behavior of solids when they come into contact at one or more points. Contact mechanics research allows for the investigation of tribology, contact stiffness, electrical contact resistance, and indentation hardness. This understanding is required for the safe and efficient design of technological systems. One of the main interesting research observations is the study of contact mechanics behavior between two brass hemisphere with different diameter ratios and friction coefficients, which subsequently becomes the subject of this study. For this study, seven diameter ratios ranging from one- to seven-folds were compared using friction coefficients of 0.05, 0.1, 0.4, and 0.8. Both experiments and simulations were performed to investigate the behavior of the contact mechanics. The experiments and simulation were designed to investigate the effect of friction coefficient and diameter ratio on Von-Misses in the loading process and deformation. The results of the finite element method simulations µ = 0 and lubricated condition experiments are coherent between each other. As a result, it is proven that the coefficient of friction has influenced the unloading deformation and von Mises stress distribution. However, the impact on the deformation ratio with a coefficient of friction from 0.05 to 0.8 does not show a significant difference. The distribution of von Mises stress on diameter ratio 1 showed similar results between the two specimens. Specimen 2 had a wider von Mises stress distribution than specimen 1 at a higher diameter ratio. From diameter ratio 3 to diameter ratio 7, there is a highly localized stress at the edge of the contact area. This region is caused by shear stress as a result of the middle material pushing the surrounding material sideways. When the friction coefficient is increased, the localized stress area decreases, which indicates that the resultant load given is reduced.
The term “contact area” refers to the total surface area of two entities in direct physical touch. When discussing an artificial hip joint, “contact area” refers to the surface area of contact between the components of the artificial hip joint (ball and cup) positioned inside the patient. Several methods can be used to figure out the contact area of an artificial hip joint, such as finite element analysis and traditional experiments on contact mechanics with hip joint simulators. The contact area in an artificial hip joint ensures load distribution. For optimal and long-term performance, the prosthetic hip joint’s contact area must be well understood for design, fitting, and monitoring. This study presented a novel method to estimate the liner surface contact area due to interaction contact in the artificial hip joint using a computer-aided design (CAD) program. This study also contrasted numerical approaches utilizing computer-aided engineering software and theoretical predictions based on Hertz theory with three-dimensional processes using CAD software to determine the contact area in the inner liner. There were no significant discrepancies in the outcomes of the three approaches.
29 December 2023 in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
The running-in process is considered an essential aspect of the comprehensive wear process. The phenomenon of running-in occurs during the initial stages of wear in the prosthetic hip joint. Within the field of tribology, the running-in phenomenon of the hip joint pertains to the mechanism by which the contact surfaces of the artificial hip joint components are adjusted and a suitable lubricating film is formed. During the process of hip joint running-in, there is an interaction between the metal surface of the ball and the joint cup, which results in adjustments being made until a steady state is achieved. The achievement of desirable wear existence and reliable performance of artificial hip joint components are reliant upon the tribological running-in of the hip joint. Despite the establishment of current modeling approaches, there remains a significant lack of understanding concerning running-in wear, particularly the metal-on-polyethylene (MoP) articulations in dual-mobility cups (DMC). An essential aspect to consider is the running-in phase of the dual mobility component. The present study employed finite element analysis to investigate the running-in behavior of dual mobility cups, wherein femoral head components were matched with polyethylene liners of varying thicknesses. The analysis of the running-in phase was conducted during the normal gait cycle. The results of this investigation may be utilized to design a dual-mobility prosthetic hip joint that exhibits minimal running-in wear.
Background and Aims: Mental and neurological disorders are a growing global concern, further intensified by the COVID‐19 pandemic. Stress management techniques, such as deep pressure therapy, have gained attention, with weighted vests commonly used for anxiety relief. However, there is limited scientific evidence supporting their efficacy. This study aimed to rigorously assess the effectiveness of a weighted vest incorporating vibrotactile stimulation in reducing anxiety by measuring physiological indicators—pulse rate and skin conductance (SC)—as well as subjective comfort ratings.Methods: A total of 30 final‐semester college students participated in the study. Participants wore a vibrotactile‐weighted vest, and both pulse rate and skin conductance (SC) were measured to gauge anxiety levels. Additionally, participants rated their comfort using a Comfort Rating Scale (CRS). Changes in pulse rate and SC were statistically analyzed, and effect sizes (Cohen's d) were calculated to assess the magnitude of the intervention's impact.Results: The weighted vest with vibrotactile stimulation resulted in a significant reduction in both pulse rate (dpulse = 0.23–0.62) and SC (dsc = 0.32–0.66), indicating a small to medium effect size in anxiety reduction. Subjective evaluations of the vest using the CRS revealed low scores on discomfort‐related items, with participants rating unfavorable statements between 1.5/10 and 4.6/10, suggesting overall comfort during use.Conclusion: This study provides compelling evidence that vibrotactile‐weighted vests effectively reduce anxiety, as indicated by both physiological measures and subjective comfort ratings. The findings support the potential of this intervention as a formal therapeutic tool for stress and anxiety reduction. Further research may explore long‐term effects and broader applications in clinical settings.
Objectives: This study aimed to evaluate the subjective acceptability and physiological response of an inflatable vest as a wearable device to stimulate calming effects. Methods: A Visual Analogue Scale (VAS) was used as a subjective measurement and an electroenceph- alogram (EEG) as an objective/physiological measurement. Results: The results showed that the subjective scores of 30 male participants rated the prototype as an ‘excellent’ device, with an average score of 81. An increase in the theta (4–8 Hz) frequency band was the most noticeable change in EEG, which represented the calming effect behavior experienced in 64% of all participants. Conclusion: The self-regulated inflatable vest could be beneficial for therapeutic purposes by inducing a calming effect.