In this study, a non-linear hue–wavelength (H-W) curve was investigated from 400 to 650 nm. To date, no study has reported on H-W relationship measurements, especially down to the 400 nm region. A digital camera mounted with complementary metal oxide semiconductor (CMOS) image sensors was used. The obtained digital images of the sample were based on an RGB-based imaging analysis rather than multispectral imaging or hyperspectral imaging. In this study, we focused on the raw image to reconstruct the H-W curve. In addition, several factors affecting the digital image, such as exposure time or international organization for standardization (ISO), were investigated. In addition, cross check of the H-W response using laser was performed. We expect that our method will be useful as an auxiliary method in the future for obtaining the fluor emission wavelength information.
We introduced a digital photo image analysis in color space to estimate the spectrum of fluor components dissolved in a liquid scintillator sample through the hue and wavelength relationship. Complementary metal oxide semiconductor (CMOS) image sensors with Bayer color filter array (CFA) technology in the digital camera were used to reconstruct and decode color images. Hue and wavelength are closely related. To date, no literature has reported the hue and wavelength relationship measurements, especially for blue or close to the UV region. The non-linear hue and wavelength relationship in the blue region was investigated using a light emitting diode source. We focused on this wavelength region, because the maximum quantum efficiency of the bi-alkali photomultiplier tube (PMT) is around 430 nm. It is necessary to have a good understanding of this wavelength region in PMT-based experiments. The CMOS Bayer CFA approach was sufficient to estimate the fluor emission spectrum in the liquid scintillator sample without using an expensive spectrophotometer.
This paper describes a practical method for obtaining the spectra of lights emitted by a fluor in a liquid scintillator (LS) using a digital camera. The emission wavelength results obtained using a digital image were compared with those obtained using a fluorescence spectrophotometer. For general users, conventional spectrophotometers are expensive and difficult to access. Moreover, their experimental measurement setup and processes are highly complicated, and they require considerable care in handling. To overcome these limitations, a feasibility study was performed to obtain the emission spectrum through image analysis. Specifically, the emission spectrum of a fluor dissolved in a liquid scintillator was obtained using digital image analysis. An image processing method was employed to convert the light irradiated during camera exposure into wavelengths. Hue (H) and wavelength (W) are closely related. Thus, we obtained an H-W response curve in the 400~450 nm wavelength region, using a light-emitting diode. Another relevant advantage of the method described in this study is its non-invasiveness in sealed LS samples. Our results showed that this method has the potential to accurately investigate the emission wavelengths of fluor within acceptable uncertainties. We envision the use of this method to perform experiments in chemistry and physics laboratories in the future.
Liquid scintillators are extensively employed as targets in neutrino experiments and in medical radiography. Perovskite nanocrystals are recognized for their tunable emission spectra and high photoluminescence quantum yields. In this study, we investigated the feasibility of using perovskites as an alternative to fluor, a substance that shifts the wavelengths. The liquid scintillator candidates were synthesized by doping perovskite nanocrystals with emission wavelengths of 450, 480, and 510 nm into fluor PPO with varying nanocrystal concentrations in a toluene solvent. The several properties of the perovskite nanocrystal-doped liquid scintillator were measured and compared with those of a secondary wavelength shifter, bis-MSB. The emission spectra of the perovskite nanocrystal-doped liquid scintillator exhibited a distinct monochromatic wavelength, indicating energy transfer from PPO to the perovskite nanocrystals. Using a radioactive source setup with two photomultiplier tubes (PMTs), the light yields, pulse shape, and wavelength shifts of the scintillation events were measured. The light yields were evaluated based on the observed Compton edges from -rays, and compared across the synthesized samples. A decrease (or increase) in area-normalized PMT pulse height was observed at higher perovskite nanocrystal (or PPO) concentrations. The results demonstrated the sufficient potential of perovskite nanocrystals as an alternative to traditional wavelength shifters in a liquid scintillator.
Neutrinos are difficult to detect because they weakly interact with matter, making their properties least known. The response of the neutrino detector depends on the optical properties of the liquid scintillator (LS). Monitoring any characteristic changes in the LS helps to understand the temporal variation of detector response. In this study, a detector filled with LS was used to study the characteristics of the neutrinos detector. We investigated a method to distinguish the concentrations of PPO and bis-MSB, which are fluors added to LS, through a photomultiplier tube (PMT) acting as an optical sensor. Conventionally, it is very challenging to discriminate the flour concentration dissolved in LS. We employed the information of pulse shape and PMT coupled with the short-pass filter. To date, no literature report on a measurement using such an experimental setup has been published. As the concentration of PPO was increased, changes in the pulse shape were observed. In addition, as the concentration of bis-MSB was increased, a decrease in the light yield was observed in the PMT equipped with the short-pass filter. This result suggests the feasibility of real-time monitoring of LS properties, which are correlated with the fluor concentration, using a PMT without extracting the LS samples from the detector during the data acquisition process.