In this study, a non-linear hue–wavelength (H-W) curve was investigated from 400 to 650 nm. To date, no study has reported on H-W relationship measurements, especially down to the 400 nm region. A digital camera mounted with complementary metal oxide semiconductor (CMOS) image sensors was used. The obtained digital images of the sample were based on an RGB-based imaging analysis rather than multispectral imaging or hyperspectral imaging. In this study, we focused on the raw image to reconstruct the H-W curve. In addition, several factors affecting the digital image, such as exposure time or international organization for standardization (ISO), were investigated. In addition, cross check of the H-W response using laser was performed. We expect that our method will be useful as an auxiliary method in the future for obtaining the fluor emission wavelength information.
Reactor-emitted electron antineutrinos can be detected via the inverse beta decay reaction, which produces a characteristic signal: a two-fold coincidence between a prompt positron event and a delayed neutron capture event within a specific time frame. While liquid scintillators are widely used for detecting neutrinos reacting with matter, detection is difficult because of the low interaction of neutrinos. In particular, it is important to distinguish between neutron (n) and gamma (γ) signals. The principle of the interaction of neutrons with matter differs from that of gamma rays with matter, and hence the detection signal’s waveform is different. Conventionally, pulse shape discrimination (PSD) is used for n/γ separation. This study developed a machine learning method to see if it is more efficient than the traditional PSD method. The possibility of n/γ discrimination in the region beyond the linear response limits was also examined, by using 10- and 2-inch photomultiplier tubes (PMTs) simultaneously. To the best of our knowledge, no study has attempted PSD in a PMT nonlinear region using artificial neural networks. Our results indicate that the proposed method has the potential to distinguish between n and γ signals in a nonlinear region.
Liquid scintillator (LS) dissolves a scintillating fluor in an organic base solvent to emit light. LS emits light when it receives energy from external sources. In this study, we developed a water-based liquid scintillator (WbLS), where a surfactant was used to mix water and oil. There are various surfactants in the market, hence, finding a suitable surfactant plays an important role in synthesizing liquid scintillators using water. We performed a feasibility study on synthesizing WbLS based on the hydrophilic-lipophilic balance (HLB) index. As far as we are concerned, no literature report on the investigation of WbLS using HLB index has been found. Long-term stability is very important for the WbLS, and it needs to be observed for at least a year for any changes. Meanwhile, as an application of WbLS, sinogram analysis was performed with Radon transformation. It was possible to reconstruct transverse images with longitudinal photo images of the WbLS sample. Optical tomography was done by combining WbLS and digital camera.
We introduced a digital photo image analysis in color space to estimate the spectrum of fluor components dissolved in a liquid scintillator sample through the hue and wavelength relationship. Complementary metal oxide semiconductor (CMOS) image sensors with Bayer color filter array (CFA) technology in the digital camera were used to reconstruct and decode color images. Hue and wavelength are closely related. To date, no literature has reported the hue and wavelength relationship measurements, especially for blue or close to the UV region. The non-linear hue and wavelength relationship in the blue region was investigated using a light emitting diode source. We focused on this wavelength region, because the maximum quantum efficiency of the bi-alkali photomultiplier tube (PMT) is around 430 nm. It is necessary to have a good understanding of this wavelength region in PMT-based experiments. The CMOS Bayer CFA approach was sufficient to estimate the fluor emission spectrum in the liquid scintillator sample without using an expensive spectrophotometer.
Liquid scintillator is widely used in various fields. This paper proposes a new base material, a mixture of alcohol and water for liquid scintillator and introduces photo image analysis to investigate electron beam irradiation on the new alcohol-based liquid scintillator. A possibility of using alcohol as a new detection solution in particle detector is briefly described. Alcohol has good solubility for fluor, is biodegradable and has low toxicity. The development of an alcohol-based liquid scintillator was investigated and some physical and optical properties of the alcohol-based liquid scintillator were measured. The energy exchange process that the absorption spectrum overlaps with the emission spectrum was seen in our alcohol-based liquid scintillator. To date, there have been no R&D studies elsewhere for use of alcohol-based liquid scintillator in particle detectors. As an application, we introduce a new measurement technique where range measurements were achieved after irradiating an alcohol-based liquid scintillator with electron beam energies of 6–12 MeV. By analyzing the range images taken by digital camera, or even mobile phone camera, it was possible to find out the fluor component dissolved in the alcohol-based liquid scintillator. This method has sufficient potential as it enables us to estimate wavelengths in the visible region without using an expensive spectrophotometer. These results can be used in medical imaging applications for the treatment of tumors or cancers where irradiation by electron beams takes place. Furthermore, alcohol-based LS could be used in future, next generation particle detectors.
A novel cardiac motion correction algorithm has been introduced recently. Unlike other segmentation-based approaches it is fully automatic and capable of correcting motion artifacts of myocardial wall and other moving structures as well as coronary arteries of the heart. In addition, it requires raw data of only less than a single rotation for motion estimation and correction, which is a significant advantage from the perspective of x-ray exposure and workflow. The aim of this study is to explore the capability of the proposed method through phantoms and in-vivo experiments. Motion correction of coronary arteries and other heart structures including myocardial wall is the main focus of the evaluation. First, we provide a brief introduction to the concept of the motion correction algorithm. Next we address the procedure of our studies using an XCAT phantom and commercially available physical phantoms. Results of XCAT phantom demonstrate that our solution significantly improves the structural similarity of coronary arteries compared to FBP (proposed: 0.94, FBP: 0.77, p<0.001). Besides, it provides significantly lower root mean square error (proposed: 20.27, FBP: 25.33, p = 0.01) of the whole heart image. Mocomo phantom study shows that the proposed method improves the visualization of coronary arteries estimated based on motion score (1: worst, 5: best) from two experienced radiologists (proposed: 3.5, FBP: 2.1, p<0.001). The results of these phantom studies reveal that the proposed has a great potential in handling motion artifacts of other heart structures as well as coronary arteries. Finally, we provide the results of in-vivo animal and human studies. The 3D and 4D heart images show a consistently superior performance in the visualization of coronary arteries along with myocardial wall and other cardiothoracic structures. Based on these findings of our studies, we are of the opinion that our solution has a considerable potential to improve temporal resolution of cardiac CT imaging. This would open the door to innovations in structural or functional diagnosis of the heart.