We have proposed and experimentally demonstrated a novel optical fiber sensor for simultaneous measurement of high temperature and gas pressure based on a Regenerated Fiber Bragg grating (RFBG) cascaded with a homemade hollow core Bragg fiber (HCBF). The HCBF functions as an anti-resonant reflecting waveguide and acts as a pressure and temperature sensing unit. The sample was fabricated and tested in our lab, exhibiting a high linear pressure and temperature sensitivity of −3.747 nm/MPa and 25.925 pm/°C in a large-dynamic range of 2 MPa and 600 °C, respectively. The RFBG, as a temperature monitor, was integrated to compensate the temperature cross-correspondence of the HCBF. By utilizing a 2 × 2 matrix obtained with the experimental results, simultaneous measurement of temperature and gas pressure can be achieved. Besides, compact size, low cost and high sensitivity make the sensor more competitive in harsh environment application.
A highly sensitive inline gas pressure sensor based on the hollow core Bragg fiber (HCBF) and harmonic Vernier effect (VE) is proposed and experimentally demonstrated. By sandwiching a segment of HCBF between the lead-in single-mode fiber (SMF) and the hollow core fiber (HCF), a cascaded Fabry–Perot interferometer is produced. The lengths of the HCBF and HCF are precisely optimized and controlled to generate the VE, achieving a high sensitivity of the sensor. Meanwhile, a digital signal processing (DSP) algorithm is proposed to research the mechanism of the VE envelope, thus providing an effective way to improve the sensor’s dynamic range based on calibrating the order of the dip. Theoretical simulations are investigated and matched well with the experimental results. The proposed sensor exhibits a maximum gas pressure sensitivity of 150.02 nm/MPa with a low temperature cross talk of 0.00235 MPa/∘C. All these advantages highlight the sensor’s enormous potential for gas pressure monitoring under various extreme conditions.
In this paper, an all-fiber sensor based on hollow core Bragg fiber (HCBF) is proposed and successfully manufactured, which can be used for human breath monitoring. Benefiting from the identical outer diameters of HCBF and single mode fibers (SMFs), the sensor can be directly constructed by sandwiching a segment of HCBF between two SMFs. Based on optical propagation properties of HCBF, the transmission light is sensitive to specific environmental change induced by human breath. Thus, the breath signals can be explicitly recorded by measuring the intensity of the transmitted laser. The sensor presents a rapid response time of ∼0.15 s and recovery time of ∼0.65 s. In addition, the HCBF-based sensor shows good insensitivity to the variation of temperature and curvature, which enables its reliable sensing performance in the dynamic and changeful environment.
A novel hollow-core anti-resonant fiber (HC-ARF) with glass-sheet conjoined nested tubes that supports five core modes of LP01-LP31 with low mode couplings, large differential group delays (DGDs), and low bending losses (BLs) is proposed. A novel cladding structure with glass-sheet conjoined nested tubes (CNT) is induced for the proposed HC-ARF which can suppress mode couplings between the LP01-LP31 modes and the cladding modes. The higher-order modes (HOMs) which are LP11-LP31 modes also have very low loss by optimizing the radius of the nested tube and the core radius. Moreover, the large effective refractive index differences Δneff between HOMs are all larger than 1 × 10−4 which contributes to a large DGD in the wavelength range from 1.3 to 1.7 µm. The bending loss of the HC-ARF is analyzed and optimized emphatically. Our calculation results show that bending losses of LP01-LP31 modes are all lower than 3.0 × 10−4 dB/m in the wavelength range from 1.4 to 1.61 µm even when the fiber bending radius of the HC-ARF is 6 cm.
26 March 2012 in Inverse Problems in Science and Engineering
A left ventricular assist device (LVAD) is a mechanical pump that helps patients with a heart failure (HF) condition. This pump works in parallel to the ailing heart and provides a continuous flow from the weak left ventricle to the ascending aorta. The current supplied to the pump motor controls the flow of blood. A new feedback control system is developed to automatically adjust the pump motor current to provide the blood flow required by the level of activity of the patient. The systemic vascular resistance (RS) is the only undeterministic variable parameter in a patient-specific model and also a key value that expresses the level of activity of the patient. The rest of the parameters are constants for a patient-specific model. To determine the level of activity of the patient, an inverse problem approach is followed. The output data (pump flow) are observed and using an optimized search technique, the best model to describe such output is selected. Furthermore, the estimated RS is used in another patient-specific cardiovascular model that assumes a healthy heart, to determine the blood flow demand. Once the physiological demand is established, the current supplied to the pump motor of the LVAD can be adjusted to achieve the desired blood flow through the cardiovascular system. This process can be performed automatically in a real-time basis using information that is readily available and thus rendering a high degree of applicability. Results from simulated data show that the feedback control system is fast and very stable.
A highly sensitive relative humidity (RH) sensor based on Fabry-Perot interferometers (FPI) is proposed and experimentally demonstrated. The sensor is fabricated by splicing a segment of hollow core Bragg fiber (HCBF) with single mode fiber (SMF) and functionalized with chitosan and ultraviolet optical adhesive (UVOA) composite at the end of HCBF to form a hygroscopic polymer film. The reflection beams from the splicing point and the two surfaces of the polymer film generate the Vernier effect in the reflection spectrum, which significantly improves the humidity sensitivity of the sensor. To demodulate the envelope based on the Vernier effect and realize multi-point sensing, a digital signal processing (DSP) algorithm is proposed to process the reflection spectrum. The performance of the DSP algorithm is theoretically analyzed and experimentally verified. The proposed sensor demonstrates a high sensitivity of 1.45 nm/% RH for RH ranging from 45% RH to 90% RH. The compact size, high sensitivity and multiplexing capability make this sensor a promising candidate for RH monitoring. Furthermore, the proposed DSP can potentially be applied to other sensors based on the Vernier effect to analyze and extract valuable information from the interference spectrum.