Tilman Emrich

Dr. Tilman Emrich

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2024 in Radiology
Verified
Journal Article
Closed access
MHMoritz C. Halfmann
Moritz C. Halfmann
SBStefanie Bockius
Stefanie Bockius
Tilman EmrichTilman Emrich
Tilman Emrich
MHMichaela Hell
Michaela Hell
USU. Joseph Schoepf
U. Joseph Schoepf
NFNicola Fink
Nicola Fink
Background Coronary CT angiography is a first-line test in coronary artery disease but is limited by severe calcifications. Photon-counting-detector (PCD) CT improves spatial resolution. Purpose To investigate the effect of improved spatial resolution on coronary stenosis assessment and reclassification. Materials and Methods Coronary stenoses were evaluated prospectively in a vessel phantom (in vitro) containing two stenoses (25%, 50%), and retrospectively in patients (in vivo) who underwent ultrahigh-spatial-resolution cardiac PCD CT (from July 2022 to April 2023). Images were reconstructed at standard resolution (section thickness, 0.6 mm; increment, 0.4 mm; Bv44 kernel), high spatial resolution (section thickness, 0.4 mm; increment, 0.2 mm; Bv44 kernel), and ultrahigh spatial resolution (section thickness, 0.2; increment, 0.1 mm; Bv64 kernel). Percentages of diameter stenosis (DS) were compared between reconstructions. In vitro values were compared with the manufacturer specifications of the phantom and patient results were assessed regarding effects on Coronary Artery Disease Reporting and Data System (CAD-RADS) reclassification. Results The in vivo sample included 114 patients (mean age, 68 years ± 9 [SD]; 71 male patients). In vitro percentage DS measurements were more accurate with increasing spatial resolution for both 25% and 50% stenoses (mean bias for standard resolution, high spatial resolution, and ultrahigh spatial resolution, respectively: 10.1%, 8.0%, and 2.3%; P < .001). In vivo results confirmed decreasing median percentage DS with increasing spatial resolution for calcified stenoses (n = 161) (standard resolution, high spatial resolution, and ultrahigh spatial resolution, respectively: 41.5% [IQR, 27.3%-58.2%], 34.8% [IQR, 23.7%-55.1%], and 26.7% [IQR, 18.6%-44.3%]; P < .001), whereas noncalcified (n = 13) and mixed plaques (n = 19) did not show evidence of a difference (P ≥ .88). Ultrahigh-spatial-resolution reconstructions led to reclassification of 62 of 114 (54.4%) patients to lower CAD-RADS category than that assigned using standard resolution. Conclusion In vivo and in vitro coronary stenosis assessment improved for calcified stenoses by using ultrahigh-spatial-resolution PCD CT reconstructions, leading to lower percentage DS compared with standard resolution and clinically relevant rates of reclassification. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by McCollough in this issue.

1 April 2023 in Radiology
Verified
Journal Article
Closed access
GAGilberto J. Aquino
Gilberto J. Aquino
JDJim O Doherty
Jim O Doherty
USU. Joseph Schoepf
U. Joseph Schoepf
BEBenjamin Ellison
Benjamin Ellison
JBJordan Byrne
Jordan Byrne
Tilman EmrichTilman Emrich
Tilman Emrich
Background Photon-counting detector (PCD) CT provides comprehensive spectral data with every acquisition, but studies evaluating myocardial extracellular volume (ECV) quantification with use of PCD CT compared with an MRI reference remain lacking. Purpose To compare ECV quantification for myocardial tissue characterization between a first-generation PCD CT system and cardiac MRI. Materials and Methods In this single-center prospective study, adults without contraindication to iodine-based contrast media underwent same-day cardiac PCD CT and MRI with native and postcontrast T1 mapping and late gadolinium enhancement for various clinical indications for cardiac MRI (the reference standard) between July 2021 and January 2022. Global and midventricular ECV were assessed with use of three methods: single-energy PCD CT, dual-energy PCD CT, and MRI T1 mapping. Quantitative comparisons among all techniques were performed. Correlation and reliability between different methods of ECV quantification were assessed with use of the Pearson correlation coefficient (r) and the intraclass correlation coefficient. Results The final sample included 29 study participants (mean age ± SD, 54 years ± 17; 15 men). There was a strong correlation of ECV between dual- and single-energy PCD CT (r = 0.91, P < .001). Radiation dose was 40% lower with dual-energy versus single-energy PCD CT (volume CT dose index, 10.1 mGy vs 16.8 mGy, respectively; P < .001). In comparison with MRI, dual-energy PCD CT showed strong correlation (r = 0.82 and 0.91, both P < .001) and good to excellent reliability (intraclass correlation coefficients, 0.81 and 0.90) for midventricular and global ECV quantification, but it overestimated ECV by approximately 2%. Single-energy PCD CT showed similar relationship with MRI but underestimated ECV by 3%. Conclusion Myocardial tissue characterization with photon-counting detector CT-based quantitative extracellular volume analysis showed a strong correlation to MRI. © RSNA, 2023 Supplemental material is available for this article.

1 October 2024 in Circulation: Cardiovascular Imaging
Verified
Journal Article
Closed access
MVMilán Vecsey-Nagy
Milán Vecsey-Nagy
GTGiuseppe Tremamunno
Giuseppe Tremamunno
USU. Joseph Schoepf
U. Joseph Schoepf
CGChiara Gnasso
Chiara Gnasso
EZEmese Zsarnóczay
Emese Zsarnóczay
Tilman EmrichTilman Emrich
Tilman Emrich
BACKGROUND: A recent simulation study proposed that stenosis measurements on coronary computed tomography (CT) angiography are influenced by the improved spatial resolution of photon-counting detector (PCD)-CT. The aim of the current study was to evaluate the impact of ultrahigh-spatial-resolution (UHR) on coronary stenosis measurements and Coronary Artery Disease Reporting and Data System (CAD-RADS) reclassification rates in patients undergoing coronary CT angiography on both PCD-CT and energy-integrating detector (EID)-CT and to compare measurements against quantitative coronary angiography. METHODS: Patients with coronary calcification on EID-CT (collimation, 192×0.6 mm) were prospectively enrolled for a research coronary CT angiography with UHR PCD-CT (collimation, 120×0.2 mm) within 30 days (between April 1, 2023 and January 31, 2024). PCD-CT was acquired with the same or lower CT dose index and equivalent contrast media volume as EID-CT. Percentage diameter stenosis (PDS) for calcified, partially calcified, and noncalcified lesions were compared between scanners. Patient-level reclassification rates for CAD-RADS were evaluated. The accuracy of PDS measurements was validated against quantitative coronary angiography in patients who underwent invasive coronary angiography. RESULTS: In total, PDS of 278 plaques were quantified in 49 patients (calcified, 202; partially calcified, 51; noncalcified, 25). PCD-CT-based PDS values were lower than EID-CT measurements for calcified (45.1±20.7 versus 54.6±19.2%; P <0.001) and partially calcified plaques (44.3±19.6 versus 54.9±20.0%; P <0.001), without significant differences for noncalcified lesions (39.1±15.2 versus 39.0±16.0%; P =0.98). The reduction in stenosis degrees led to a 49.0% (24/49) reclassification rate to a lower CAD-RADS with PCD-CT. In a subset of 12 patients with 56 lesions, UHR–based PDS values showed higher agreement with quantitative coronary angiography (mean difference, 7.3%; limits of agreement, −10.7%/25.2%) than EID-CT measurements (mean difference, 17.4%; limits of agreement, −6.9%/41.7%). CONCLUSIONS: Compared with conventional EID-CT, UHR PCD-CT results in lower PDS values and more accurate stenosis measurements in coronary plaques with calcified components and leads to a substantial Coronary Artery Disease Reporting and Data System reclassification rate in 49.0% of patients.

25 March 2021 in European Radiology Experimental
Verified
Journal Article
Open access
PDF file
Tilman EmrichTilman Emrich
Tilman Emrich
MHMoritz Halfmann
Moritz Halfmann
USU. Joseph Schoepf
U. Joseph Schoepf
KKKarl-Friedrich Kreitner
Karl-Friedrich Kreitner
Ischemic heart disease and its sequelae are one of the major contributors to morbidity and mortality worldwide. Over the last decades, technological developments have strengthened the role of noninvasive imaging for detection, risk stratification, and management of patients with ischemic heart disease. Cardiac magnetic resonance (CMR) imaging incorporates both functional and morphological characterization of the heart to determine presence, acuteness, and severity of ischemic heart disease by evaluating myocardial wall motion and function, the presence and extent of myocardial edema, ischemia, and scarring. Currently established clinical protocols have already demonstrated their diagnostic and prognostic value. Nevertheless, there are emerging imaging technologies that provide additional information based on advanced quantification of imaging biomarkers and improved diagnostic accuracy, therefore potentially allowing reduction or avoidance of contrast and/or stressor agents. The aim of this review is to summarize the current state of the art of CMR imaging for ischemic heart disease and to provide insights into promising future developments.

1 March 2025 in Radiology
Verified
Journal Article
Closed access
MVMilán Vecsey-Nagy
Milán Vecsey-Nagy
GTGiuseppe Tremamunno
Giuseppe Tremamunno
USU. Joseph Schoepf
U. Joseph Schoepf
CGChiara Gnasso
Chiara Gnasso
EZEmese Zsarnóczay
Emese Zsarnóczay
AVAkos Varga-Szemes
Akos Varga-Szemes
Coronary plaque quantification using ultrahigh-spatial-resolution photon-counting detector CT reduced visualized total plaque volume by nearly one-third and improved the reproducibility of low-attenuation plaque measurements compared with that of energy-integrating detector CT.