Background Coronary CT angiography is a first-line test in coronary artery disease but is limited by severe calcifications. Photon-counting-detector (PCD) CT improves spatial resolution. Purpose To investigate the effect of improved spatial resolution on coronary stenosis assessment and reclassification. Materials and Methods Coronary stenoses were evaluated prospectively in a vessel phantom (in vitro) containing two stenoses (25%, 50%), and retrospectively in patients (in vivo) who underwent ultrahigh-spatial-resolution cardiac PCD CT (from July 2022 to April 2023). Images were reconstructed at standard resolution (section thickness, 0.6 mm; increment, 0.4 mm; Bv44 kernel), high spatial resolution (section thickness, 0.4 mm; increment, 0.2 mm; Bv44 kernel), and ultrahigh spatial resolution (section thickness, 0.2; increment, 0.1 mm; Bv64 kernel). Percentages of diameter stenosis (DS) were compared between reconstructions. In vitro values were compared with the manufacturer specifications of the phantom and patient results were assessed regarding effects on Coronary Artery Disease Reporting and Data System (CAD-RADS) reclassification. Results The in vivo sample included 114 patients (mean age, 68 years ± 9 [SD]; 71 male patients). In vitro percentage DS measurements were more accurate with increasing spatial resolution for both 25% and 50% stenoses (mean bias for standard resolution, high spatial resolution, and ultrahigh spatial resolution, respectively: 10.1%, 8.0%, and 2.3%; P < .001). In vivo results confirmed decreasing median percentage DS with increasing spatial resolution for calcified stenoses (n = 161) (standard resolution, high spatial resolution, and ultrahigh spatial resolution, respectively: 41.5% [IQR, 27.3%-58.2%], 34.8% [IQR, 23.7%-55.1%], and 26.7% [IQR, 18.6%-44.3%]; P < .001), whereas noncalcified (n = 13) and mixed plaques (n = 19) did not show evidence of a difference (P ≥ .88). Ultrahigh-spatial-resolution reconstructions led to reclassification of 62 of 114 (54.4%) patients to lower CAD-RADS category than that assigned using standard resolution. Conclusion In vivo and in vitro coronary stenosis assessment improved for calcified stenoses by using ultrahigh-spatial-resolution PCD CT reconstructions, leading to lower percentage DS compared with standard resolution and clinically relevant rates of reclassification. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by McCollough in this issue.

1 March 2025 in Radiology
Verified
Journal Article
Closed access
MVMilán Vecsey-Nagy
Milán Vecsey-Nagy
GTGiuseppe Tremamunno
Giuseppe Tremamunno
USU. Joseph Schoepf
U. Joseph Schoepf
CGChiara Gnasso
Chiara Gnasso
EZEmese Zsarnóczay
Emese Zsarnóczay
AVAkos Varga-Szemes
Akos Varga-Szemes
Coronary plaque quantification using ultrahigh-spatial-resolution photon-counting detector CT reduced visualized total plaque volume by nearly one-third and improved the reproducibility of low-attenuation plaque measurements compared with that of energy-integrating detector CT.

1 June 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
YYYang Yang
Yang Yang
NFNicola Fink
Nicola Fink
Tilman EmrichTilman Emrich
Tilman Emrich
DGDirk Graafen
Dirk Graafen
RRRosa Richter
Rosa Richter
MHMoritz C. Halfmann
Moritz C. Halfmann
(1) Background: Photon-counting detector (PCD) CT offers a wide variety of kernels and sharpness levels for image reconstruction. The aim of this retrospective study was to determine optimal settings for coronary CT angiography (CCTA). (2) Methods: Thirty patients (eight female, mean age 63 ± 13 years) underwent PCD-CCTA in a high-pitch mode. Images were reconstructed using three different kernels and four sharpness levels (Br36/40/44/48, Bv36/40/44/48, and Qr36/40/44/48). To analyze objective image quality, the attenuation, image noise, contrast-to-noise ratio (CNR), and vessel sharpness were quantified in proximal and distal coronaries. For subjective image quality, two blinded readers assessed image noise, visually sharp reproduction of coronaries, and the overall image quality using a five-point Likert scale. (3) Results: Attenuation, image noise, CNR, and vessel sharpness significantly differed across kernels (all p < 0.001), with the Br-kernel reaching the highest attenuation. With increasing kernel sharpness, image noise and vessel sharpness increased, whereas CNR continuously decreased. Reconstruction with Br-kernel generally had the highest CNR (Br > Bv > Qr), except Bv-kernel had a superior CNR at sharpness level 40. Bv-kernel had significantly higher vessel sharpness than Br- and Qr-kernel (p < 0.001). Subjective image quality was rated best for kernels Bv40 and Bv36, followed by Br36 and Qr36. (4) Conclusion: Reconstructions with kernel Bv40 are beneficial to achieve optimal image quality in spectral high-pitch CCTA using PCD-CT.

1 August 2024 in Radiology: Cardiothoracic Imaging
Verified
Journal Article
Closed access
NFNicola Fink
Nicola Fink
Tilman EmrichTilman Emrich
Tilman Emrich
USU. Joseph Schoepf
U. Joseph Schoepf
EZEmese Zsarnoczay
Emese Zsarnoczay
JOJim O’dOherty
Jim O’dOherty
AVAkos Varga-Szemes
Akos Varga-Szemes
Purpose To investigate the impact of plaque size and density on virtual noncontrast (VNC)-based coronary artery calcium scoring (CACS) using photon-counting detector CT and to provide safety net reconstructions for improved detection of subtle plaques in patients whose VNC-based CACS would otherwise be erroneously zero when compared with true noncontrast (TNC)-based CACS. Materials and Methods In this prospective study, CACS was evaluated in a phantom containing calcifications with different diameters (5, 3, and 1 mm) and densities (800, 400, and 200 mg/cm3) and in participants who underwent TNC and contrast-enhanced cardiac photon-counting detector CT (July 2021-March 2022). VNC images were reconstructed at different virtual monoenergetic imaging (55-80 keV) and quantum iterative reconstruction (QIR) levels (QIR,1-4). TNC scans at 70 keV with QIR off served as the reference standard. In vitro CACS was analyzed using standard settings (3.0-mm sections, kernel Qr36, 130-HU threshold). Calcification detectability and CACS of small and low-density plaques were also evaluated using 1.0-mm sections, kernel Qr44, and 120- or 110-HU thresholds. Safety net reconstructions were defined based on background Agatston scores and evaluated in vivo in TNC plaques initially nondetectable using standard VNC reconstructions. Results The in vivo cohort included 63 participants (57.8 years ± 15.5 [SD]; 37 [59%] male, 26 [41%] female). Correlation and agreement between standard CACSVNC and CACSTNC were higher in large- and medium-sized and high- and medium-density than in low-density plaques (in vitro: intraclass correlation coefficient [ICC] ≥ 0.90; r > 0.9 vs ICC = 0.20-0.48; r = 0.5-0.6). Small plaques were not detectable using standard VNC reconstructions. Calcification detectability was highest using 1.0-mm sections, kernel Qr44, 120- and 110-HU thresholds, and QIR level of 2 or less VNC reconstructions. Compared with standard VNC, using safety net reconstructions (55 keV, QIR 2, 110-HU threshold) for in vivo subtle plaque detection led to higher detection (increased by 89% [50 of 56]) and improved correlation and agreement of CACSVNC with CACSTNC (in vivo: ICC = 0.51-0.61; r = 0.6). Conclusion Compared with TNC-based calcium scoring, VNC-based calcium scoring was limited for small and low-density plaques but improved using safety net reconstructions, which may be particularly useful in patients with low calcium scores who would otherwise be treated based on potentially false-negative results. Keywords: Coronary Artery Calcium CT, Photon-Counting Detector CT, Virtual Noncontrast, Plaque Size, Plaque Density Supplemental material is available for this article. © RSNA, 2024.

24 November 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
DGDirk Graafen
Dirk Graafen
MHMoritz C. Halfmann
Moritz C. Halfmann
Tilman EmrichTilman Emrich
Tilman Emrich
YYYang Yang
Yang Yang
MKMichael Kreuter
Michael Kreuter
TJTobias Jorg
Tobias Jorg
Photon-counting detector computed tomography (PCD-CT) yields improved spatial resolution. The combined use of PCD-CT and a modern iterative reconstruction method, known as quantum iterative reconstruction (QIR), has the potential to significantly improve the quality of lung CT images. In this study, we aimed to analyze the impacts of different slice thicknesses and QIR levels on low-dose ultra-high-resolution (UHR) PCD-CT imaging of the lungs. Our study included 51 patients with different lung diseases who underwent unenhanced UHR-PCD-CT scans. Images were reconstructed using three different slice thicknesses (0.2, 0.4, and 1.0 mm) and three QIR levels (2–4). Noise levels were determined in all reconstructions. Three raters evaluated the delineation of anatomical structures and conspicuity of various pulmonary pathologies in the images compared to the clinical reference reconstruction (1.0 mm, QIR-3). The highest QIR level (QIR-4) yielded the best image quality. Reducing the slice thickness to 0.4 mm improved the delineation and conspicuity of pathologies. The 0.2 mm reconstructions exhibited lower image quality due to high image noise. In conclusion, the optimal reconstruction protocol for low-dose UHR-PCD-CT of the lungs includes a slice thickness of 0.4 mm, with the highest QIR level. This optimized protocol might improve the diagnostic accuracy and confidence of lung imaging.

18 June 2023 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
MHMoritz C. Halfmann
Moritz C. Halfmann
LMLukas Müller
Lukas Müller
UHUrs von Henning
Urs von Henning
RKRoman Kloeckner
Roman Kloeckner
TSTheresia Schöler
Theresia Schöler
Tilman EmrichTilman Emrich
Tilman Emrich
MRI T2 mapping has been proven to be sensitive to the level of blood oxygenation. We hypothesized that impaired exercise capacity in chronic heart failure is associated with a greater difference between right (RV) to left ventricular (LV) blood pool T2 relaxation times due to a higher level of peripheral blood desaturation, compared to patients with preserved exercise capacity and to healthy controls. Patients with chronic heart failure (n = 70) who had undergone both cardiac MRI (CMR) and a 6-min walk test (6MWT) were retrospectively identified. Propensity score matched healthy individuals (n = 35) served as control group. CMR analyses included cine acquisitions and T2 mapping to obtain blood pool T2 relaxation times of the RV and LV. Following common practice, age- and gender-adjusted nominal distances and respective percentiles were calculated for the 6MWT. The relationship between the RV/LV T2 blood pool ratio and the results from 6MWT were evaluated by Spearman’s correlation coefficients and regression analyses. Inter-group differences were assessed by independent t-tests and univariate analysis of variance. The RV/LV T2 ratio moderately correlated with the percentiles of nominal distances in the 6MWT (r = 0.66) while ejection fraction, end-diastolic and end-systolic volumes showed no correlation (r = 0.09, 0.07 and − 0.01, respectively). In addition, there were significant differences in the RV/LV T2 ratio between patients with and without significant post-exercise dyspnea (p = 0.001). Regression analyses showed that RV/LV T2 ratio was an independent predictor of the distance walked and the presence of post-exercise dyspnea (p < 0.001). The proposed RV/LV T2 ratio, obtained by two simple measurements on a routinely acquired four-chamber T2 map, was superior to established parameters of cardiac function to predict exercise capacity and the presence of post-exercise dyspnea in patients with chronic heart failure.