Chiara Gnasso

Dr. Chiara Gnasso


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2024 in Circulation: Cardiovascular Imaging
Verified
Journal Article
Closed access
MVMilán Vecsey-Nagy
Milán Vecsey-Nagy
GTGiuseppe Tremamunno
Giuseppe Tremamunno
USU. Joseph Schoepf
U. Joseph Schoepf
CGChiara Gnasso
Chiara Gnasso
EZEmese Zsarnóczay
Emese Zsarnóczay
Tilman EmrichTilman Emrich
Tilman Emrich
BACKGROUND: A recent simulation study proposed that stenosis measurements on coronary computed tomography (CT) angiography are influenced by the improved spatial resolution of photon-counting detector (PCD)-CT. The aim of the current study was to evaluate the impact of ultrahigh-spatial-resolution (UHR) on coronary stenosis measurements and Coronary Artery Disease Reporting and Data System (CAD-RADS) reclassification rates in patients undergoing coronary CT angiography on both PCD-CT and energy-integrating detector (EID)-CT and to compare measurements against quantitative coronary angiography. METHODS: Patients with coronary calcification on EID-CT (collimation, 192×0.6 mm) were prospectively enrolled for a research coronary CT angiography with UHR PCD-CT (collimation, 120×0.2 mm) within 30 days (between April 1, 2023 and January 31, 2024). PCD-CT was acquired with the same or lower CT dose index and equivalent contrast media volume as EID-CT. Percentage diameter stenosis (PDS) for calcified, partially calcified, and noncalcified lesions were compared between scanners. Patient-level reclassification rates for CAD-RADS were evaluated. The accuracy of PDS measurements was validated against quantitative coronary angiography in patients who underwent invasive coronary angiography. RESULTS: In total, PDS of 278 plaques were quantified in 49 patients (calcified, 202; partially calcified, 51; noncalcified, 25). PCD-CT-based PDS values were lower than EID-CT measurements for calcified (45.1±20.7 versus 54.6±19.2%; P <0.001) and partially calcified plaques (44.3±19.6 versus 54.9±20.0%; P <0.001), without significant differences for noncalcified lesions (39.1±15.2 versus 39.0±16.0%; P =0.98). The reduction in stenosis degrees led to a 49.0% (24/49) reclassification rate to a lower CAD-RADS with PCD-CT. In a subset of 12 patients with 56 lesions, UHR–based PDS values showed higher agreement with quantitative coronary angiography (mean difference, 7.3%; limits of agreement, −10.7%/25.2%) than EID-CT measurements (mean difference, 17.4%; limits of agreement, −6.9%/41.7%). CONCLUSIONS: Compared with conventional EID-CT, UHR PCD-CT results in lower PDS values and more accurate stenosis measurements in coronary plaques with calcified components and leads to a substantial Coronary Artery Disease Reporting and Data System reclassification rate in 49.0% of patients.

1 March 2025 in Radiology
Verified
Journal Article
Closed access
MVMilán Vecsey-Nagy
Milán Vecsey-Nagy
GTGiuseppe Tremamunno
Giuseppe Tremamunno
USU. Joseph Schoepf
U. Joseph Schoepf
CGChiara Gnasso
Chiara Gnasso
EZEmese Zsarnóczay
Emese Zsarnóczay
AVAkos Varga-Szemes
Akos Varga-Szemes
Coronary plaque quantification using ultrahigh-spatial-resolution photon-counting detector CT reduced visualized total plaque volume by nearly one-third and improved the reproducibility of low-attenuation plaque measurements compared with that of energy-integrating detector CT.

1 July 2021 in Atherosclerosis
Verified
Journal Article
Closed access
ASAlessandra Scoccia
Alessandra Scoccia
GGGuglielmo Gallone
Guglielmo Gallone
ACAlberto Cereda
Alberto Cereda
APAnna Palmisano
Anna Palmisano
DVDavide Vignale
Davide Vignale
MTMarco Toselli
Marco Toselli

3 June 2021 in The Anatolian Journal of Cardiology
Verified
Journal Article
Open access
Alessandro SticchiAlessandro Sticchi
Alessandro Sticchi
ACAlberto Cereda
Alberto Cereda
MTMarco Toselli
Marco Toselli
AEAntonio Esposito
Antonio Esposito
APAnna Palmisano
Anna Palmisano
FGFrancesco Giannini
Francesco Giannini

5 May 2025 in Journal of Cardiovascular Computed Tomography
Verified
Journal Article
Open access
GTGiuseppe Tremamunno
Giuseppe Tremamunno
AVAkos Varga-Szemes
Akos Varga-Szemes
USU Joseph Schoepf
U Joseph Schoepf
DKDmitrij Kravchenko
Dmitrij Kravchenko
MHMuhammad Taha Hagar
Muhammad Taha Hagar
MVMilan Vecsey-Nagy
Milan Vecsey-Nagy
Quantitative coronary stenosis and plaque volumes have demonstrated intra-individual differences between ultrahigh-resolution (UHR) photon-counting detector (PCD)-CT and energy-integrating detector (EID)-CT. This study aimed to assess the impact of UHR PCD-CT on semiquantitative scores of coronary artery disease (CAD) burden compared with EID-CT. Patients undergoing coronary CT angiography (CCTA) on an EID-CT system for stable chest pain or pre-transcatheter aortic valve replacement evaluation were prospectively enrolled for UHR PCD-CT scan within 30 days. Both datasets were visually evaluated using five established semiquantitative scores: Segment Involvement Score (SIS), Segment Stenosis Score (SSS), Multivessel Aggregate Stenosis Score (MVAS), CCTA-adapted Leaman score (CT-LeSc), and Coronary Artery Disease Reporting and Data System (CAD-RADS). Additionally, the total number of detected plaques and high-risk features were reported (positive remodeling, spotty calcification, low-attenuation, and napkin-ring sign). The cohort comprised 46 patients (37 men, 68.4 ​± ​6.9 years). When assessing stenosis severity, PCD-CT showed lower SSS (3.5 [1.3-5.0] vs 6.5 [3.0-9.8], p ​< ​0.001), MVAS (5.5 [4.0-7.0] vs 7.0 [5.0-9.0], p ​< ​0.001), and CT-LeSc (10.4 [8.5-13.9] vs 11.2 [8.8-15.4], p ​= ​0.032). Furthermore, 52 ​% (24/46) of patients were reclassified to a lower CAD-RADS category compared to EID-CT. In terms of CAD extent, PCD-CT demonstrated higher SIS (8.0 [6.0-9.0] vs 7.0 [6.0-8.8], p ​= ​0.018) and plaque count (9.0 [7.0-13.8] vs 7.0 [7.0-9.8] p ​< ​0.001). Positive remodeling was less frequent in PCD-CT datasets (2.0 [1.0-4.3] vs 1.0 [0.0-3.0], p ​= ​0.012), with no significant differences in other high-risk features. The use of UHR PCD-CT detects less severe, but more extensive CAD compared to EID-CT. The effect of such CCTA-based differences on individual risk stratification needs further investigation.

1 January 2023 in Radiology
Verified
Journal Article
Closed access
DVDavide Vignale
Davide Vignale
APAnna Palmisano
Anna Palmisano
CCCaterina Colantoni
Caterina Colantoni
LBLisa Brunetti
Lisa Brunetti
VNValeria Nicoletti
Valeria Nicoletti
AEAntonio Esposito
Antonio Esposito