Arash Mohammadzadeh Gonabadi

Dr. Arash Mohammadzadeh Gonabadi

Rehabilitation Science and Engineering, Madonna Rehabilitation Hospital, Lincoln, Alabama, USA
orcid
Madonna Rehabilitation Hospitals, Institute for Rehabilitati...

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 January 2017 in Journal of Sandwich Structures & Materials
Verified
Journal Article
Closed access
MDMohammad Nouri Damghani
Mohammad Nouri Damghani
Arash Mohammadzadeh GonabadiArash Mohammadzadeh Gonabadi
Arash Mohammadzadeh Gonabadi
The sandwich structures with aluminum foam core and metal surfaces have widespread use in the absorption of energy, because they are light weighted with high performance in dissipating energy. The cell structure of the foam core is subjected to plastic deformation in the constant compression level that absorbs a lot of kinetic energy before destruction of the structure. In this research, experimental tests of low-velocity impact on the sandwich structure by a drop machine are simulated by LS-DYNA software. Numerical results are obtained for different velocities and weights of projectile on samples of aluminum foam core sandwich panels with relative density (the ratio of the density of aluminum foam to the density of solid aluminum) of 18, 23, and 27. The results are compared with experimental results which reveal a good conformity. As well, from the numerical simulations, the effect of weight, velocity and energy of the projectile and the density of the foam core on the global deformation and energy loss rate of projectile have been studied.

3 May 2021 in Biomechanics
Verified
Journal Article
Open access
PDF file
FFFarahnaz Fallahtafti
Farahnaz Fallahtafti
Arash Mohammadzadeh GonabadiArash Mohammadzadeh Gonabadi
Arash Mohammadzadeh Gonabadi
KSKaeli Samson
Kaeli Samson
JYJennifer Yentes
Jennifer Yentes
Margin of stability (MOS) is considered a measure of mechanical gait stability. Due to broad application of treadmills in gait assessment experiments, we aimed to determine if walking on a treadmill vs. overground would affect MOS during three speed-matched conditions. Eight healthy young participants walked on a treadmill and overground at Slow, Preferred, and Fast speed-matched conditions. The mean and variability (standard deviation) of the MOS in anterior-posterior and mediolateral directions at heel contact were calculated. Anterior-posterior and mediolateral mean MOS values decreased with increased speed for both overground and treadmill; although mediolateral mean MOS was always wider on the treadmill compared to overground. Due to lack of optic flow and different proprioceptive inputs during treadmill walking, subjects may employ strategies to increase their lateral stability on treadmill compared to overground. Anterior-posterior MOS variability increased with speed overground, while it did not change on treadmill, which might be due to the fixed speed of treadmill. Whereas, lateral variability on both treadmill and overground was U-shaped. Walking at preferred speed was less variable (may be interpreted as more stable) laterally, compared to fast and slow speeds. Caution should be given when interpreting MOS between modes and speeds of walking. As sagittal plane walking is functionally unstable, this raises the consideration as to the meaningfulness of using MOS as a global measure of gait stability in this direction.

28 October 2020 in PLOS Computational Biology
Verified
Journal Article
Open access
PDF file
Arash Mohammadzadeh GonabadiArash Mohammadzadeh Gonabadi
Arash Mohammadzadeh Gonabadi
PAProkopios Antonellis
Prokopios Antonellis
PMPhilippe Malcolm
Philippe Malcolm
Motion capture laboratories can measure multiple variables at high frame rates, but we can only measure the average metabolic rate of a stride using respiratory measurements. Biomechanical simulations with equations for calculating metabolic rate can estimate the time profile of metabolic rate within the stride cycle. A variety of methods and metabolic equations have been proposed, including metabolic time profile estimations based on joint parameters. It is unclear whether differences in estimations are due to differences in experimental data or due to methodological differences. This study aimed to compare two methods for estimating the time profile of metabolic rate, within a single dataset. Knowledge about the consistency of different methods could be useful for applications such as detecting which part of the gait cycle causes increased metabolic cost in patients. Here we compare estimations of metabolic rate time profiles using a musculoskeletal and a joint-space method. The musculoskeletal method was driven by kinematics and electromyography data and used muscle metabolic rate equations, whereas the joint-space method used metabolic rate equations based on joint parameters. Both estimations of changes in stride average metabolic rate correlated significantly with large changes in indirect calorimetry from walking on different grades showing that both methods accurately track changes. However, estimations of changes in stride average metabolic rate did not correlate significantly with more subtle changes in indirect calorimetry due to walking with different shoe inclinations, and both the musculoskeletal and joint-space time profile estimations did not correlate significantly with each other except in the most downward shoe inclination. Estimations of the relative cost of stance and swing matched well with previous simulations with similar methods and estimations from experimental perturbations. Rich experimental datasets could further advance time profile estimations. This knowledge could be useful to develop therapies and assistive devices that target the least metabolically economic part of the gait cycle. Respiratory oxygen consumption measurements allow recording of the average metabolic cost of walking, but the slow rate of these measurements prevents assessing which part of the gait cycle has the highest metabolic cost. Simulation methods allow estimation of the time profile of metabolic cost within the gait cycle. We compared estimations of the metabolic cost of walking using a method that is based on kinematic and electromyography recordings from participants in conjunction with muscle metabolic rate equations and a method based on joint kinematics and kinetics. While both methods are able to accurately estimate large changes in the average metabolic cost from walking on different inclinations, the time profiles estimated by the two methods are different, indicating that estimations of the time profile of metabolic cost are dependent on the estimation method. Both estimation methods matched well with the results from experimental perturbation studies that suggest that the metabolic cost of the swing phase is approximately 10% to 20% of the metabolic cost of the entire gait cycle. Advances in estimations of the time profile of metabolic cost could lead to practical applications such as designing rehabilitation robots that assist specifically during the phase with the highest metabolic cost.

16 March 2022 in Science Robotics
Verified
Journal Article
Closed access
PAProkopios Antonellis
Prokopios Antonellis
Arash Mohammadzadeh GonabadiArash Mohammadzadeh Gonabadi
Arash Mohammadzadeh Gonabadi
Sara MyersSara Myers
Sara Myers
IPIraklis I. Pipinos
Iraklis I. Pipinos
PMPhilippe Malcolm
Philippe Malcolm
The metabolic rate of walking can be reduced by applying a constant forward force at the center of mass. It has been shown that the metabolically optimal constant force magnitude minimizes propulsion ground reaction force at the expense of increased braking. This led to the hypothesis that selectively assisting propulsion could lead to greater benefits. We used a robotic waist tether to evaluate the effects of forward forces with different timings and magnitudes. Here, we show that it is possible to reduce the metabolic rate of healthy participants by 48% with a greater efficiency ratio of metabolic cost reduction per unit of net aiding work compared with other assistive robots. This result was obtained using a sinusoidal force profile with peak timing during the middle of the double support. The same timing could also reduce the metabolic rate in patients with peripheral artery disease. A model explains that the optimal force profile accelerates the center of mass into the inverted pendulum movement during single support. Contrary to the hypothesis, the optimal force timing did not entirely coincide with propulsion. Within the field of wearable robotics, there is a trend to use devices to mimic biological torque or force profiles. Such bioinspired actuation can have relevant benefits; however, our results demonstrate that this is not necessarily optimal for reducing metabolic rate.

15 June 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Arash Mohammadzadeh GonabadiArash Mohammadzadeh Gonabadi
Arash Mohammadzadeh Gonabadi
FFFarahnaz Fallahtafti
Farahnaz Fallahtafti
PAProkopios Antonellis
Prokopios Antonellis
IPIraklis Pipinos
Iraklis Pipinos
Sara MyersSara Myers
Sara Myers
Understanding metabolic cost through biomechanical data, including ground reaction forces (GRFs) and joint moments, is vital for health, sports, and rehabilitation. The long stabilization time (2–5 min) of indirect calorimetry poses challenges in prolonged tests. This study investigated using artificial neural networks (ANNs) to predict metabolic costs from the GRF and joint moment time series. Data from 20 participants collected over 270 walking trials, including the GRF and joint moments, formed a detailed dataset. Two ANN models were crafted, netGRF for the GRF and netMoment for joint moments, and both underwent training, validation, and testing to validate their predictive accuracy for metabolic cost. NetGRF (six hidden layers, two input delays) showed significant correlations: 0.963 (training), 0.927 (validation), 0.883 (testing), p < 0.001. NetMoment (three hidden layers, one input delay) had correlations of 0.920 (training), 0.956 (validation), 0.874 (testing), p < 0.001. The models’ low mean squared errors reflect their precision. Using Partial Dependence Plots, we demonstrated how gait cycle phases affect metabolic cost predictions, pinpointing key phases. Our findings show that the GRF and joint moments data can accurately predict metabolic costs via ANN models, with netGRF being notably consistent. This emphasizes ANNs’ role in biomechanics as a crucial method for estimating metabolic costs, impacting sports science, rehabilitation, assistive technology development, and fostering personalized advancements.

30 March 2024 in Biomimetics
Verified
Journal Article
Open access
PDF file
Arash Mohammadzadeh GonabadiArash Mohammadzadeh Gonabadi
Arash Mohammadzadeh Gonabadi
PAProkopios Antonellis
Prokopios Antonellis
ADAlex C. Dzewaltowski
Alex C. Dzewaltowski
Sara MyersSara Myers
Sara Myers
IPIraklis Pipinos
Iraklis Pipinos
PMPhilippe Malcolm
Philippe Malcolm
This study focused on designing and evaluating a bilateral semi-rigid hip exoskeleton. The exoskeleton assisted the hip joint, capitalizing on its proximity to the body’s center of mass. Unlike its rigid counterparts, the semi-rigid design permitted greater freedom of movement. A temporal force-tracking controller allowed us to prescribe torque profiles during walking. We ensured high accuracy by tuning control parameters and series elasticity. The evaluation involved experiments with ten participants across ten force profile conditions with different end-timings and peak magnitudes. Our findings revealed a trend of greater reductions in metabolic cost with assistance provided at later timings in stride and at greater magnitudes. Compared to walking with the exoskeleton powered off, the largest reduction in metabolic cost was 9.1%. This was achieved when providing assistance using an end-timing at 44.6% of the stride cycle and a peak magnitude of 0.11 Nm kg−1. None of the tested conditions reduced the metabolic cost compared to walking without the exoskeleton, highlighting the necessity for further enhancements, such as a lighter and more form-fitting design. The optimal end-timing aligns with findings from other soft hip exosuit devices, indicating a comparable interaction with this prototype to that observed in entirely soft exosuit prototypes.