Prokopios Antonellis

Dr. Prokopios Antonellis

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 October 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
PAProkopios Antonellis
Prokopios Antonellis
SGSamuel Galle
Samuel Galle
DCDirk De Clercq
Dirk De Clercq
PMPhilippe Malcolm
Philippe Malcolm
Exoskeletons can influence human gait. A healthy gait is characterized by a certain amount of variability compared to a non-healthy gait that has more inherent variability; however which exoskeleton assistance parameters are necessary to avoid increasing gait variability or to potentially lower gait variability below that of unassisted walking are unknown. This study investigated the interaction effects of exoskeleton timing and power on gait variability. Ten healthy participants walked on a treadmill with bilateral ankle-foot exoskeletons under ten conditions with different timing (varied from 36% to 54% of the stride) and power (varied from 0.2 to 0.5 W∙kg-1) combinations. We used the largest Lyapunov exponent (LyE) and maximum Floquet multiplier (FM) to evaluate the stride-to-stride fluctuations of the kinematic time series. We found the lowest LyE at the ankle and a significant reduction versus powered-off with exoskeleton power (summed for both legs) of 0.45 W∙kg-1 and actuation timing at 48% of the stride cycle. At the knee, a significant positive effect of power and a negative interaction effect of power and timing were found for LyE. We found significant positive interaction effects of the square of timing and power for LyE at the knee and hip joints. In contrast, the FM at the ankle increased with increasing power and later timing. We found a significant negative effect of power and a positive interaction effect of power and timing for FM at the knee and no significant effects of any of the exoskeleton parameters for FM at the hip. The ability of the exoskeleton to reduce the LyE at the ankle joint offers new possibilities in terms of altering gait variability, which could have applications for using exoskeletons as rehabilitation devices. Further efforts could examine if it is possible to simultaneously reduce the LyE and FM at one or more lower limb joints.

16 March 2022 in Science Robotics
Verified
Journal Article
Closed access
PAProkopios Antonellis
Prokopios Antonellis
Arash Mohammadzadeh GonabadiArash Mohammadzadeh Gonabadi
Arash Mohammadzadeh Gonabadi
Sara MyersSara Myers
Sara Myers
IPIraklis I. Pipinos
Iraklis I. Pipinos
PMPhilippe Malcolm
Philippe Malcolm
The metabolic rate of walking can be reduced by applying a constant forward force at the center of mass. It has been shown that the metabolically optimal constant force magnitude minimizes propulsion ground reaction force at the expense of increased braking. This led to the hypothesis that selectively assisting propulsion could lead to greater benefits. We used a robotic waist tether to evaluate the effects of forward forces with different timings and magnitudes. Here, we show that it is possible to reduce the metabolic rate of healthy participants by 48% with a greater efficiency ratio of metabolic cost reduction per unit of net aiding work compared with other assistive robots. This result was obtained using a sinusoidal force profile with peak timing during the middle of the double support. The same timing could also reduce the metabolic rate in patients with peripheral artery disease. A model explains that the optimal force profile accelerates the center of mass into the inverted pendulum movement during single support. Contrary to the hypothesis, the optimal force timing did not entirely coincide with propulsion. Within the field of wearable robotics, there is a trend to use devices to mimic biological torque or force profiles. Such bioinspired actuation can have relevant benefits; however, our results demonstrate that this is not necessarily optimal for reducing metabolic rate.

15 June 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Arash Mohammadzadeh GonabadiArash Mohammadzadeh Gonabadi
Arash Mohammadzadeh Gonabadi
FFFarahnaz Fallahtafti
Farahnaz Fallahtafti
PAProkopios Antonellis
Prokopios Antonellis
IPIraklis Pipinos
Iraklis Pipinos
Sara MyersSara Myers
Sara Myers
Understanding metabolic cost through biomechanical data, including ground reaction forces (GRFs) and joint moments, is vital for health, sports, and rehabilitation. The long stabilization time (2–5 min) of indirect calorimetry poses challenges in prolonged tests. This study investigated using artificial neural networks (ANNs) to predict metabolic costs from the GRF and joint moment time series. Data from 20 participants collected over 270 walking trials, including the GRF and joint moments, formed a detailed dataset. Two ANN models were crafted, netGRF for the GRF and netMoment for joint moments, and both underwent training, validation, and testing to validate their predictive accuracy for metabolic cost. NetGRF (six hidden layers, two input delays) showed significant correlations: 0.963 (training), 0.927 (validation), 0.883 (testing), p < 0.001. NetMoment (three hidden layers, one input delay) had correlations of 0.920 (training), 0.956 (validation), 0.874 (testing), p < 0.001. The models’ low mean squared errors reflect their precision. Using Partial Dependence Plots, we demonstrated how gait cycle phases affect metabolic cost predictions, pinpointing key phases. Our findings show that the GRF and joint moments data can accurately predict metabolic costs via ANN models, with netGRF being notably consistent. This emphasizes ANNs’ role in biomechanics as a crucial method for estimating metabolic costs, impacting sports science, rehabilitation, assistive technology development, and fostering personalized advancements.

1 January 2019 in Neuroscience Letters
Verified
Journal Article
Closed access
BGBoman R. Groff
Boman R. Groff
PAProkopios Antonellis
Prokopios Antonellis
KSKendra K. Schmid
Kendra K. Schmid
BKBrian A. Knarr
Brian A. Knarr
NSNicholas Stergiou
Nicholas Stergiou

30 March 2024 in Biomimetics
Verified
Journal Article
Open access
PDF file
Arash Mohammadzadeh GonabadiArash Mohammadzadeh Gonabadi
Arash Mohammadzadeh Gonabadi
PAProkopios Antonellis
Prokopios Antonellis
ADAlex C. Dzewaltowski
Alex C. Dzewaltowski
Sara MyersSara Myers
Sara Myers
IPIraklis Pipinos
Iraklis Pipinos
PMPhilippe Malcolm
Philippe Malcolm
This study focused on designing and evaluating a bilateral semi-rigid hip exoskeleton. The exoskeleton assisted the hip joint, capitalizing on its proximity to the body’s center of mass. Unlike its rigid counterparts, the semi-rigid design permitted greater freedom of movement. A temporal force-tracking controller allowed us to prescribe torque profiles during walking. We ensured high accuracy by tuning control parameters and series elasticity. The evaluation involved experiments with ten participants across ten force profile conditions with different end-timings and peak magnitudes. Our findings revealed a trend of greater reductions in metabolic cost with assistance provided at later timings in stride and at greater magnitudes. Compared to walking with the exoskeleton powered off, the largest reduction in metabolic cost was 9.1%. This was achieved when providing assistance using an end-timing at 44.6% of the stride cycle and a peak magnitude of 0.11 Nm kg−1. None of the tested conditions reduced the metabolic cost compared to walking without the exoskeleton, highlighting the necessity for further enhancements, such as a lighter and more form-fitting design. The optimal end-timing aligns with findings from other soft hip exosuit devices, indicating a comparable interaction with this prototype to that observed in entirely soft exosuit prototypes.

6 October 2023 in Physical Therapy
Verified
Journal Article
Closed access
PDF file
AWAngela Weston
Angela Weston
PAProkopios Antonellis
Prokopios Antonellis
PFPeter C Fino
Peter C Fino
CHCarrie W Hoppes
Carrie W Hoppes
MLMark E Lester
Mark E Lester
LKLaurie A King
Laurie A King
Objective: The aim of this study was to establish the test–retest reliability of metrics obtained from wearable inertial sensors that reflect turning performance during tasks designed to imitate various turns in daily activity. Methods: Seventy-one adults who were healthy completed 3 turning tasks: a 1-minute walk along a 6-m walkway, a modified Illinois Agility Test (mIAT), and a complex turning course (CTC). Peak axial turning and rotational velocity (yaw angular velocity) were extracted from wearable inertial sensors on the head, trunk, and lumbar spine. Intraclass correlation coefficients (ICCs) were established to assess the test–retest reliability of average peak turning speed for each task. Lap time was collected for reliability analysis as well. Results: Turning speed across all tasks demonstrated good to excellent reliability, with the highest reliability noted for the CTC (45-degree turns: ICC = 0.73–0.81; 90-degree turns: ICC = 0.71–0.83; and 135-degree turns: ICC = 0.72–0.80). The reliability of turning speed during 180-degree turns from the 1-minute walk was consistent across all body segments (ICC = 0.74–0.76). mIAT reliability ranged from fair to excellent (end turns: ICC = 0.52–0.72; mid turns: ICC = 0.50–0.56; and slalom turns: ICC = 0.66–0.84). The CTC average lap time demonstrated good test–retest reliability (ICC = 0.69), and the mIAT average lap time test–retest reliability was excellent (ICC = 0.91). Conclusion: Turning speed measured by inertial sensors is a reliable outcome across a variety of ecologically valid turning tasks that can be easily tested in a clinical environment. Impact: Turning performance is a reliable and important measure that should be included in clinical assessments and clinical trials.