For moderate-to-severe glaucoma, trabeculectomy remains the “gold standard” intraocular pressure (IOP)-lowering treatment; nonetheless, this method requires extensive post-operative maintenance. Microinvasive glaucoma surgery (MIGS) treatments are designed to lessen intra- and post-operative care burden while offering an acceptable IOP decrease for individuals with mild to moderate glaucoma. The PreserFlo® MicroShunt (previously InnFocus MicroShunt) is an 8.5 mm glaucoma drainage device manufactured from poly(styrene-block-isobutylene-block-styrene) (SIBS), an extremely biocompatible and bioinert material. The lumen is narrow enough to prevent hypotony, but big enough to avoid being obstructed by sloughed cells or pigment. The device is implanted ab externo, as a stand-alone procedure or in conjunction with cataract surgery, with intraoperative mitomycin C, and a bleb is produced under the conjunctiva and Tenon’s capsule. The MicroShunt was CE-marked in 2012 and designed for primary open-angle glaucoma, the IOP of which remains uncontrolled after maximally tolerated topical treatment. Several clinical trials evaluating the MicroShunt’s long-term safety and effectiveness have been conducted, highlighting the effectiveness of the device over time, along with a tolerable safety profile. The present review aims to gather evidence of PreserFlo’s effectiveness and safety results almost 10 years after its introduction, and furthermore, to compare it with other MIGS and with the gold-standard trabeculectomy for glaucoma management.
3 June 2025 in Progress in Retinal and Eye Research
The adoption of artificial intelligence (AI) in ophthalmology holds great promise for improving diagnostic accuracy, optimizing workflows, and enhancing patient care. However, regulatory, ethical, and technical challenges must be addressed to ensure its safe and effective implementation. Bias in AI can lead to disparities in healthcare delivery, while the "black-box problem" raises concerns about transparency and trust. Ethical principles must guide AI integration, particularly regarding patient safety, accountability, and liability. Privacy risks related to data collection and security are especially critical in ophthalmology, where large imaging datasets are essential. Additionally, AI-generated inaccuracies, or "hallucinations," pose potential risks to clinical decision-making. Cybersecurity threats targeting AI-powered healthcare systems further emphasize the need for robust protections. Despite these challenges, AI has the potential to improve access to ophthalmic care, particularly in underserved regions, as seen in AI-assisted diabetic retinopathy screening. However, financial and infrastructural barriers remain significant obstacles to widespread adoption. Addressing these issues requires collaboration among stakeholders, including regulators, healthcare providers, AI developers, and policymakers, to establish clear guidelines and promote trustworthy AI systems. This review explores key regulatory and ethical concerns and highlights strategies to ensure the responsible integration of AI into ophthalmology.
Myopia is becoming more common across the world, affecting approximately two billion people and rising. Different kinds of therapies (optical, pharmaceutical, environmental, or behavioral) have been proposed to decrease myopia progression, but with variable results and a lack of standardization. The evidence that targeted myopic defocus inhibits eye length growth has paved the way for several contact and spectacle lense designs to induce a peripheral defocus, thus slowing myopia progression, but the perfect configuration has yet to be defined. One of the newest and more promising approaches in this field is the use of Defocus Incorporated Multiple Segments (DIMS) lenses. These lenses are built from the assumption that targeted myopic defocus, produced by 396 mid-peripheral lenslets with positive power, inhibits eye length growth. Recent studies have highlighted the effectiveness of these lenses compared to children who had worn single vision spectacle lenses, in terms of myopia control and tolerability. Despite the evidence that these lenses can help slow down the progression of myopia, the occasional mid-peripheral aberrations they can induce, as well as the overall eye strain that comes with wearing them, should not be overlooked. The aim of this review is to give attention to the advantages and the shortfalls of this new approach and to evaluate its effectiveness in clinical practice.
Background: The purpose of this study is to compare the morphology of six-month follow-up blebs created by a subconjunctival glaucoma surgical device (XEN45) to those created by a PreserFlo MicroShunt with a sub-Tenon insertion, utilizing AS-OCT. Methods: A retrospective study of 29 eyes who underwent XEN45 implantation and 29 eyes who underwent PreserFlo MicroShunt implantation. The patients were analyzed at 24 h, 1 week, 1 month, 3 months and 6 months. At each visit, the maturation and morphological alterations of the blebs were observed, as well as connections with the IOP. Results: In both groups, IOP showed significant reduction at all follow ups (p < 0.0001). In XEN group, the most common bleb morphology in the immediate postoperative was the subconjuntival separation type (42%) followed by the uniform type (34%), with a trend inversion at 6 month follow up (51% of uniform type). On the contrary, the most common morphology after PreserFlo was the multiple internal layer (55%), which showed a tendency to reduce over time and was substituted by the microcystic multiform, whose percentage increased over time (17% at day 1 vs. 44% at month 6). Uniform appearance was associated by the posterior episcleral fluid (PEF) lake presence. Both horizontal and vertical diameters significantly increased over time. Conclusion: XEN and PreserFlo implantation resulted in the production of diffuse blebs with different characteristics, which may influence IOP lowering capacity and bleb revisions necessity over time.
Intraoperative optical coherence tomography (iOCT) is a noninvasive imaging technique that gives real-time dynamic feedback on surgical procedures. iOCT was first employed in vitreoretinal surgery, but successively served as a guidance in several anterior segment surgical approaches: keratoplasty, implantable Collamer lens (ICL) implantation, and cataract surgery. Among all of those approaches, the unbeatable features of iOCT are fully exploited in anterior and posterior lamellar keratoplasty, and the purpose of this review is to focus on the advantages and shortfalls of iOCT in these techniques, in order to assess whether this technology could be a real step forward. In deep anterior lamellar keratoplasty (DALK), iOCT is useful to evaluate the needle depth into the corneal stroma, the big bubble dissection plane, and residual stromal bed, thus aiding the standardization of the technique and the reduction of failures. In Descemet stripping automated endothelial keratoplasty (DSAEK), iOCT allowed for clear visibility of fluid at the graft/host interface, allowing for immediate rescue maneuvers and granting the best graft apposition. In Descemet membrane endothelial keratoplasty (DMEK), iOCT can track the lenticule unfolding in real time and assess graft orientation even in severe hazy corneas, thus optimizing surgical times, as well as avoiding the use of potentially hazardous exterior markers (such as the “S” stamp) and preventing unnecessary manipulation of the graft. Overall, the role of iOCT appeared crucial in several complicated cases, overcoming the difficulties of poor visualization in a fast, non-invasive way, thus raising this approach as possible gold standard for challenging conditions. Further improvements in the technology may enable autonomous centering and tracking, overcoming the current constraint of instrument-induced shadowing.
There is no consensus on whether amblyopia affects the retinal vascular plexus and morphology. Previous studies focused on the differences between amblyopic patients and normal controls without evaluating amblyopic eyes after patching. To evaluate differences in the superficial vascular density of amblyopic eyes, normal eyes, and amblyopic eyes reaching normal BCVA after patch therapy, OCTA was used. All patients underwent a comprehensive ophthalmological examination, including visual acuity, refraction, ocular motility tests, and anterior and posterior segment examination. OCTA was performed by an expert physician using the Zeiss Cirrus 5000-HD-OCT Angioplex (Carl Zeiss, Meditec, Inc., Dublin, OH, USA). OCTA scans were performed using a 3 × 3 mm2 and 6 × 6 mm2 fovea-centered image setting. The mean outer macular vessel density in the previously amblyopic group was 19.15 ± 0.51%. This was statistically significantly higher than in both the amblyopic group (18.70 ± 1.14%) and the normal controls (18.18 ± 1.40%) (p = 0.014). The previously amblyopic group also significantly differed from both normal controls and amblyopic eyes with regards to the inner (p = 0.011), outer (p = 0.006), and full (p = 0.003) macular perfusion. Finally, linear regression analysis revealed that BCVA was linearly correlated to outer perfusion in amblyopic (p = 0.003) and ex amblyopic eyes (p < 0.001). Considering the cross-sectional nature of our study, from our results, we can only hypothesize a possible correlation between light stimulation and retinal vasculature development. However, further longitudinal studies are needed to support this hypothesis.