Maria Aymerich

Dr. Maria Aymerich

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 February 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
AOAlberto Otero-Cacho
Alberto Otero-Cacho
MAMaria Aymerich
Maria Aymerich
MFM.Teresa Flores-
M.Teresa Flores-
MPMiguel Abal Posada
Miguel Abal Posada
Ezequiel AlvarezEzequiel Alvarez
Ezequiel Alvarez
AMAlberto. P. Munuzuri
Alberto. P. Munuzuri
Understanding hemodynamics in blood circulation is crucial in order to unveil the mechanisms underlying the formation of stenosis and atherosclerosis. In fact, there are experimental evidences pointing out to the existence of some given vessel configurations that are more likely to develop the above mentioned pathologies. Along this manuscript, we performed an exhaustive investigation in a simplified model aiming to characterize by means of physical quantities those regions and configurations in vessel bifurcations that are more likely to develop such pathologies. The two-fold analysis is based, on the one hand, on numerical simulations (via CFD) and, on the other hand, on experiments realized in an ad-hoc designed polydimethylsiloxane (PDMS) channel with the appropriate parameters and appropriate fluid flows. The results obtained demonstrate that low velocity regions and low shear stress zones are located in the outer walls of bifurcations. In fact, we found that there is a critical range of bifurcation angles that is more likely to vascular disease than the others in correspondence with some experimental evidence. The effect of the inflow velocity on this critical range is also analyzed.

1 October 2015 in Colloids and Surfaces B: Biointerfaces
Verified
Journal Article
Closed access
DNDaniel Nieto
Daniel Nieto
RCRamiro Couceiro
Ramiro Couceiro
MAMaria Aymerich
Maria Aymerich
RLRafael Lopez-Lopez
Rafael Lopez-Lopez
MPMiguel Abal Posada
Miguel Abal Posada
MFM.Teresa Flores-
M.Teresa Flores-

9 October 2023 in Life
Verified
Journal Article
Open access
PDF file
PFPaolo Niccolò Franco
Paolo Niccolò Franco
AGAlejandra García-Baizán
Alejandra García-Baizán
MAMaria Aymerich
Maria Aymerich
CMCesare Maino
Cesare Maino
SFSofia Frade-Santos
Sofia Frade-Santos
MOMilagros Otero-García
Milagros Otero-García
In female patients, acute pelvic pain can be caused by gynaecological, gastrointestinal, and urinary tract pathologies. Due to the variety of diagnostic possibilities, the correct assessment of these patients may be challenging. The most frequent gynaecological causes of acute pelvic pain in non-pregnant women are pelvic inflammatory disease, ruptured ovarian cysts, ovarian torsion, and degeneration or torsion of uterine leiomyomas. On the other hand, spontaneous abortion, ectopic pregnancy, and placental disorders are the most frequent gynaecological entities to cause acute pelvic pain in pregnant patients. Ultrasound (US) is usually the first-line diagnostic technique because of its sensitivity across most common aetiologies and its lack of radiation exposure. Computed tomography (CT) may be performed if ultrasound findings are equivocal or if a gynaecologic disease is not initially suspected. Magnetic resonance imaging (MRI) is an extremely useful second-line technique for further characterisation after US or CT. This pictorial review aims to review the spectrum of gynaecological entities that may manifest as acute pelvic pain in the emergency department and to describe the imaging findings of these gynaecological conditions obtained with different imaging techniques.

25 August 2016 in Materials
Verified
Journal Article
Open access
PDF file
MAMaria Aymerich
Maria Aymerich
AGAna Gomez
Ana Gomez
Ezequiel AlvarezEzequiel Alvarez
Ezequiel Alvarez
MFM.Teresa Flores-
M.Teresa Flores-
A study of PDMS (polydimethylsiloxane) sol-gel–coated channels fabricated using soft lithography and a laser direct writing technique is presented. PDMS is a biocompatible material that presents a high versatility to reproduce several structures. It is widely employed in the fabrication of preclinical devices due to its advantages but it presents a rapid chemical deterioration to organic solvents. The use of sol-gel layers to cover the PDMS overcomes this problem since it provides the robustness of glass for the structures made with PDMS, decreasing its deterioration and changing the biocompatibility of the surface. In this work, PDMS channels are coated with three different kinds of sol-gel compositions (60MTES/40TEOS, 70MTES/30TISP and 80MTES/20TISP). The endothelial cell adhesion to the different coated devices is evaluated in order to determine the most suitable sol-gel preparation conditions to enhance cellular adhesion.

26 May 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
MAMaria Aymerich
Maria Aymerich
AGAlejandra García-Baizán
Alejandra García-Baizán
PFPaolo Niccolò Franco
Paolo Niccolò Franco
MGMariña González
Mariña González
PFPilar San Miguel Fraile
Pilar San Miguel Fraile
MOMilagros Otero-García
Milagros Otero-García
Background: Clear cell renal cell carcinoma (ccRCC) is the most common subtype of renal cancer, and its prognosis is closely linked to the International Society of Urological Pathology (ISUP) grade. While histopathological evaluation remains the gold standard for grading, non-invasive methods, such as radiomics, offer potential for automated classification. This study aims to develop a radiomics-based machine learning model for the ISUP grade classification of ccRCC using nephrographic-phase CT images, with an emphasis on model interpretability through SHAP (SHapley Additive exPlanations) values. Objective: To develop and interpret a radiomics-based machine learning model for classifying ISUP grade in clear cell renal cell carcinoma (ccRCC) using nephrographic-phase CT images. Materials and Methods: This retrospective study included 109 patients with histopathologically confirmed ccRCC. Radiomic features were extracted from the nephrographic-phase CT scans. Feature robustness was evaluated via intraclass correlation coefficient (ICC), followed by redundancy reduction using Pearson correlation and minimum Redundancy Maximum Relevance (mRMR). Logistic regression, support vector machine, and random forest classifiers were trained using 8-fold cross-validation. SHAP values were computed to assess feature contribution. Results: The logistic regression model achieved the highest classification performance, with an accuracy of 82% and an AUC of 0.86. SHAP analysis identified major axis length, busyness, and large area emphasis as the most influential features. These variables represented shape and texture information, critical for distinguishing between high and low ISUP grades. Conclusions: A radiomics-based logistic regression model using nephrographic-phase CT enables accurate, non-invasive classification of ccRCC according to ISUP grade. The use of SHAP values enhances model transparency, supporting clinical interpretability and potential adoption in precision oncology.

1 June 2017 in Biofabrication
Verified
Journal Article
Closed access
PDF file
MAMaria Aymerich
Maria Aymerich
Ezequiel AlvarezEzequiel Alvarez
Ezequiel Alvarez
Carmen Bao-VarelaCarmen Bao-Varela
Carmen Bao-Varela
IMIsabel Moscoso
Isabel Moscoso
JGJose R Gonzalez-Juanatey
Jose R Gonzalez-Juanatey
MFM.Teresa Flores-
M.Teresa Flores-
In this work a method for fabricating functionalized preclinical devices is presented. The manufacturing process combines a laser indirect writing technique to fabricate a soda-lime glass master and soft-lithography methods to obtain the final structure in polydimethylsiloxane (PDMS). The roughness of the device is modified in a controlled manner by applying a post-thermal treatment to the master, and thus devices with different roughness values are created. The PDMS devices are fully covered with human umbilical vein cells in a two-step process. In order to determine the most suitable device to perform bioassays, the cell attachment to the channel is evaluated with regards to the walls roughness when flow experiments are carried out.