Kensuke Sasaki

Dr. Kensuke Sasaki


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 October 2021 in IEEE Transactions on Electromagnetic Compatibility
Verified
Journal Article
Closed access
AHAkimasa Hirata
Akimasa Hirata
YDYinliang Diao
Yinliang Diao
TOTeruo Onishi
Teruo Onishi
KSKensuke Sasaki
Kensuke Sasaki
Seungyoung AhnSeungyoung Ahn
Seungyoung Ahn
JCJi Chen
Ji Chen
This article reviews recent standardization activities and scientific studies related to the assessment of human exposure to electromagnetic fields (EMF). The differences of human exposure standards and assessment of consumer products and medical applications are summarized. First, we reviewed human body modeling and tissue dielectric properties. Then, we explain the rationale of current exposure standards from the viewpoint of EMF and the standardization process for product compliance based on these exposure standards. The assessment of wireless power transfer, as an example of emerging wireless devices, and environmental EMFs in our daily lives are reviewed. Safety in magnetic resonance systems, where the EMF exposure is much larger than from typical consumer devices, is also reviewed. Finally, we summarize future research directions and research needs for EMF safety.

8 July 2022 in Physics in Medicine & Biology
Verified
Journal Article
Open access
KSKensuke Sasaki
Kensuke Sasaki
EPEmily Porter
Emily Porter
Essam RashedEssam Rashed
Essam Rashed
LFLourdes Farrugia
Lourdes Farrugia
GSGernot Schmid
Gernot Schmid
The dielectric properties of biological tissues are fundamental pararmeters that are essential for electromagnetic modeling of the human body. The primary database of dielectric properties compiled in 1996 on the basis of dielectric measurements at frequencies from 10 Hz to 20 GHz has attracted considerable attention in the research field of human protection from non-ionizing radiation. This review summarizes findings on the dielectric properties of biological tissues at frequencies up to 1 THz since the database was developed. Although the 1996 database covered general (normal) tissues, this review also covers malignant tissues that are of interest in the research field of medical applications. An intercomparison of dielectric properties based on reported data is presented for several tissue types. Dielectric properties derived from image-based estimation techniques developed as a result of recent advances in dielectric measurement are also included. Finally, research essential for future advances in human body modeling is discussed.

1 August 2014 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
KSKensuke Sasaki
Kensuke Sasaki
KWK Wake
K Wake
SWS Watanabe
S Watanabe
Numerous studies have reported the measurements of the dielectric properties of the skin. Clarifying the manner in which the human body interacts with electromagnetic waves is essential for medical research and development, as well as for the safety assessment of electromagnetic wave exposure. The skin comprises several layers: the epidermis, the dermis, and the subcutaneous fat. Each of these skin layers has a different constitution; however, the previous measurements of their dielectric properties were typically conducted on tissue which included all three layers of the skin. This study presents novel dielectric property data for the epidermis and dermis with in vitro measurement at frequencies ranging from 0.5 GHz to 110 GHz. Measured data was compared with literature values; in particular, the findings were compared with Gabriel's widely used data on skin dielectric properties. The experimental results agreed with the data reported by Gabriel for the dermis of up to 20 GHz, which is the upper limit of the range of frequencies at which Gabriel reported measurements. For frequencies of 20-100 GHz, the experimental results indicated larger values than those extrapolated from Gabriel's data using parametric expansion. For frequencies over 20 GHz, the dielectric properties provided by the parametric model tend toward the experimental results for the epidermis with increasing frequency.

13 June 2014 in Radio Science
Verified
Journal Article
Open access
PDF file
KSKensuke Sasaki
Kensuke Sasaki
KWKanako Wake
Kanako Wake
SWSoichi Watanabe
Soichi Watanabe
In this paper, we developed best fit values for parameters in the Cole-Cole model for the dielectric properties of 43 biological tissues and organs. We developed a parameter-fitting algorithm to build an empirical data set for frequencies between 1 MHz and 20 GHz. Using the dielectric properties obtained from the fitted Cole-Cole parameters, we conducted numerical dosimetry, assessed energy absorption inside a human body exposed to electromagnetic radiation, and compared the results with those obtained on a de facto database.

20 January 2023 in IEEE Access
Verified
Journal Article
Open access
KLKun Li
Kun Li
SKSachiko Kodera
Sachiko Kodera
DPDragan Poljak
Dragan Poljak
YDYinliang Diao
Yinliang Diao
KSKensuke Sasaki
Kensuke Sasaki
AHAkimasa Hirata
Akimasa Hirata
International organizations have collaborated to revise standards and guidelines for human protection from exposure to electromagnetic fields. In the frequency range of 6–300 GHz, the permissible spatially averaged epithelial/absorbed power density, which is primarily derived from thermal modeling, is considered the basic restriction. However, for the averaging methods of the epithelial/absorbed power density inside human tissues, only a few groups have presented calculated results obtained using different exposure conditions and numerical methods. Because experimental validation is extremely difficult in this frequency range, this paper presents the first intercomparison study of the calculated epithelial/absorbed power density inside a human body model exposed to different frequency sources ranging from 10–90 GHz. This intercomparison aims to clarify the difference in the calculated results caused by different numerical electromagnetic methods in dosimetry analysis from 11 research groups using planar skin models. To reduce the comparison variances caused by various key parameters, computational conditions (e.g., the antenna type, dimensions, and dielectric properties of the skin models) were unified. The results indicated that the maximum relative standard deviation (RSD) of the peak spatially averaged epithelial/absorbed power densities for one- and three-layer skin models were less than 17.49% and 17.39%, respectively, when using a dipole antenna as the exposure source. For the dipole array antenna, the corresponding maximum RSD increased to 32.49% and 42.55%, respectively. Under the considered exposure scenarios, the RSD in the spatially averaged epithelial/absorbed power densities decreased from 42.55% to 16.7% when the frequency was increased from 10–90 GHz. Furthermore, the deviation from the two equations recommended by the exposure guidelines for deriving the spatially averaged epithelial/absorptive power density was mostly within 1 dB. The fair agreement in the intercomparison results demonstrates that the variances of the spatially averaged epithelial/absorbed power densities calculated using planar skin models are marginal.

9 November 2021 in IEEE Access
Verified
Journal Article
Open access
KLKun Li
Kun Li
YDYinliang Diao
Yinliang Diao
KSKensuke Sasaki
Kensuke Sasaki
APAlexander Prokop
Alexander Prokop
DPDragan Poljak
Dragan Poljak
WHWalid El Hajj
Walid El Hajj
Recently, international exposure guidelines/standards for human protection from electromagnetic fields were revised. For frequencies between 6-300 GHz, the permissible incident power density is defined as the reference level, which is derived from a new metric “absorbed/epithelial power density” based on thermal modeling. However, only a few groups computed the power density and the resultant temperature rise at frequencies greater than 6 GHz, where their exposure conditions were different. This study presents the first intercomparison study of the incident power density and the resultant temperature rise in a human body exposed to different frequency sources ranging from 10 to 90 GHz. This intercomparison aims to clarify the main causes of numerical calculation errors in dosimetry analyses through objective comparison of computation results from six organizations using their numerical methods with various body and antenna models. The intercomparison results indicate that the maximum relative standard deviation (RSD) of peak spatially averaged incident power densities for dipole and dipole array antennas is less than 22.1% and 6.3%, respectively. The maximum RSD of the heating factor, which is defined as the ratio of the peak temperature elevation at the skin surface to the peak spatially averaged incident power density in free space, for dipole and dipole array antennas is less than 43.2% and 41.2%, respectively. The deviations in the heating factors caused by different body models and dielectric/thermal parameters are within 33.1% and 19.6% at 10 and 30 GHz, respectively, when the antenna-to-skin model distance is greater than 5 mm. Under this condition (>5 mm), the deviation in the heating factors caused by different antenna models at 30 GHz does not exceed 26.3%. The fair agreement among the intercomparison results demonstrates that numerical calculation errors of dosimetry analyses caused by the definition of spatially averaged incident power density are marginal.