Lukas Müller

Dr. Lukas Müller


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 October 2021 in Cancers
Verified
Journal Article
Open access
PDF file
LMLukas Müller
Lukas Müller
FHFelix Hahn
Felix Hahn
AMAline Mähringer-Kunz
Aline Mähringer-Kunz
FSFabian Stoehr
Fabian Stoehr
SGSimon Johannes Gairing
Simon Johannes Gairing
RKRoman Kloeckner
Roman Kloeckner
The novel CRP–albumin–lymphocyte (CALLY) index is an improved immunonutritive scoring system, based on serum C-reactive protein (CRP), serum albumin, and the lymphocyte count. It has shown promise as a prognostic index for patients with hepatocellular carcinoma (HCC) undergoing resections. This study evaluated the prognostic ability of the CALLY index for patients with HCC undergoing transarterial chemoembolization (TACE). We retrospectively identified 280 treatment-naïve patients with HCC that underwent an initial TACE at our institution, between 2010 and 2020. We compared the CALLY index to established risk factors in univariate and multivariate regression analyses for associations with median overall survival (OS). A low CALLY score was associated with low median OS (low vs. high CALLY: 9.0 vs. 24.0 months, p < 0.001). In the multivariate analysis, the CALLY index remained an independent prognostic predictor (p = 0.008). Furthermore, all factors of the CALLY index reached significance in univariate and in-depth multivariate analyses. However, the concordance index (C-index) of the CALLY index (0.60) was similar to the C-indices of established immunonutritive and inflammation scoring systems (range: 0.54 to 0.63). In conclusion, the CALLY index showed promise as a stratification tool for patients with HCC undergoing TACE. Notably, the CALLY index was not superior to other immunonutritive and inflammation scoring systems in predicting the median OS. Thus, future studies should re-evaluate the mathematical calculation of the index, particularly the contributions of individual parameters.

1 February 2024 in Radiology
Verified
Journal Article
Closed access
MHMoritz C. Halfmann
Moritz C. Halfmann
SBStefanie Bockius
Stefanie Bockius
Tilman EmrichTilman Emrich
Tilman Emrich
MHMichaela Hell
Michaela Hell
USU. Joseph Schoepf
U. Joseph Schoepf
NFNicola Fink
Nicola Fink
Background Coronary CT angiography is a first-line test in coronary artery disease but is limited by severe calcifications. Photon-counting-detector (PCD) CT improves spatial resolution. Purpose To investigate the effect of improved spatial resolution on coronary stenosis assessment and reclassification. Materials and Methods Coronary stenoses were evaluated prospectively in a vessel phantom (in vitro) containing two stenoses (25%, 50%), and retrospectively in patients (in vivo) who underwent ultrahigh-spatial-resolution cardiac PCD CT (from July 2022 to April 2023). Images were reconstructed at standard resolution (section thickness, 0.6 mm; increment, 0.4 mm; Bv44 kernel), high spatial resolution (section thickness, 0.4 mm; increment, 0.2 mm; Bv44 kernel), and ultrahigh spatial resolution (section thickness, 0.2; increment, 0.1 mm; Bv64 kernel). Percentages of diameter stenosis (DS) were compared between reconstructions. In vitro values were compared with the manufacturer specifications of the phantom and patient results were assessed regarding effects on Coronary Artery Disease Reporting and Data System (CAD-RADS) reclassification. Results The in vivo sample included 114 patients (mean age, 68 years ± 9 [SD]; 71 male patients). In vitro percentage DS measurements were more accurate with increasing spatial resolution for both 25% and 50% stenoses (mean bias for standard resolution, high spatial resolution, and ultrahigh spatial resolution, respectively: 10.1%, 8.0%, and 2.3%; P < .001). In vivo results confirmed decreasing median percentage DS with increasing spatial resolution for calcified stenoses (n = 161) (standard resolution, high spatial resolution, and ultrahigh spatial resolution, respectively: 41.5% [IQR, 27.3%-58.2%], 34.8% [IQR, 23.7%-55.1%], and 26.7% [IQR, 18.6%-44.3%]; P < .001), whereas noncalcified (n = 13) and mixed plaques (n = 19) did not show evidence of a difference (P ≥ .88). Ultrahigh-spatial-resolution reconstructions led to reclassification of 62 of 114 (54.4%) patients to lower CAD-RADS category than that assigned using standard resolution. Conclusion In vivo and in vitro coronary stenosis assessment improved for calcified stenoses by using ultrahigh-spatial-resolution PCD CT reconstructions, leading to lower percentage DS compared with standard resolution and clinically relevant rates of reclassification. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by McCollough in this issue.

4 July 2023 in Tomography
Verified
Journal Article
Open access
PDF file
Johannes Matthias WeimerJohannes Matthias Weimer
Johannes Matthias Weimer
NWNina Widmer
Nina Widmer
KSKai-Uwe Strelow
Kai-Uwe Strelow
Paula HopfPaula Hopf
Paula Hopf
HBHolger Buggenhagen
Holger Buggenhagen
JWJulia Weinmann-Menke
Julia Weinmann-Menke
Introduction: Ultrasound diagnostics is an important examination method in everyday clinical practice, but student education is often inadequate for acquiring sufficient basic skills. Individual universities have therefore started integrating (extra)curricular training concepts into medical education. This study aimed to evaluate sustainable skills development through participation in peer-assisted ultrasound courses. Methods: From 2017, students in the clinical part of medical school could opt for extracurricular peer-assisted ultrasound courses. Depending on the format (10-week course/2-day compact course) these comprised 20 teaching units focusing on abdominal and emergency ultrasonography. Students attending compulsory workshops at the start of their practical year were enrolled in this study, allowing for a comparison between the study group (attended ultrasound course) and the control group (did not attend ultrasound course). Competency from two out of four practical exams (subjects: “aorta”, “gallbladder”, “kidney” and “lung”) was measured, and a theory test on the same subject areas (“pathology recognition”) was administered. Additional questions concerned biographical data, subjective competency assessment (7-point Likert scale), and “attitude to ultrasound training in the curriculum”. Results: Analysis included 302 participants in total. Ultrasound courses had been attended on average 2.5 years earlier (10-week course) and 12 months earlier (2-day compact course), respectively. The study group (n = 141) achieved significantly better results than the control group (n = 161) in the long-term follow-up. This applies both to practical exams (p < 0.01) and theory tests (p < 0.01). After course attendance, participants reported a significantly higher subjective assessment of theoretical (p < 0.01) and practical (p < 0.01) ultrasound skills. Conclusions: Peer-assisted ultrasound courses can sustainably increase both theoretical and practical competency of medical students. This highlights the potential and need for standardised implementation of ultrasound courses in the medical education curriculum.

9 May 2019 in Liver International
Verified
Journal Article
Closed access
PDF file
FHFelix Hahn
Felix Hahn
LMLukas Müller
Lukas Müller
FSFabian Stöhr
Fabian Stöhr
AMAline Mähringer‐Kunz
Aline Mähringer‐Kunz
SSSebastian Schotten
Sebastian Schotten
RKRoman Kloeckner
Roman Kloeckner

10 February 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
Johannes Matthias WeimerJohannes Matthias Weimer
Johannes Matthias Weimer
MRMaximilian Rink
Maximilian Rink
LMLukas Müller
Lukas Müller
KDKlaus Dirks
Klaus Dirks
CICarlotta Ille
Carlotta Ille
JKJulian Künzel
Julian Künzel
In Germany, progress assessments in head and neck ultrasonography training have been carried out mainly theoretically and lack standardisation. Thus, quality assurance and comparisons between certified courses from various course providers are difficult. This study aimed to develop and integrate a direct observation of procedural skills (DOPS) in head and neck ultrasound education and explore the perceptions of both participants and examiners. Five DOPS tests oriented towards assessing basic skills were developed for certified head and neck ultrasound courses on national standards. DOPS tests were completed by 76 participants from basic and advanced ultrasound courses (n = 168 documented DOPS tests) and evaluated using a 7-point Likert scale. Ten examiners performed and evaluated the DOPS after detailed training. The variables of “general aspects” (6.0 Scale Points (SP) vs. 5.9 SP; p = 0.71), “test atmosphere” (6.3 SP vs. 6.4 SP; p = 0.92), and “test task setting” (6.2 SP vs. 5.9 SP; p = 0.12) were positively evaluated by all participants and examiners. There were no significant differences between a basic and advanced course in relation to the overall results of DOPS tests (p = 0.81). Regardless of the courses, there were significant differences in the total number of points achieved between individual DOPS tests. DOPS tests are accepted by participants and examiners as an assessment tool in head and neck ultrasound education. In view of the trend toward “competence-based” teaching, this type of test format should be applied and validated in the future.

1 June 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
YYYang Yang
Yang Yang
NFNicola Fink
Nicola Fink
Tilman EmrichTilman Emrich
Tilman Emrich
DGDirk Graafen
Dirk Graafen
RRRosa Richter
Rosa Richter
MHMoritz C. Halfmann
Moritz C. Halfmann
(1) Background: Photon-counting detector (PCD) CT offers a wide variety of kernels and sharpness levels for image reconstruction. The aim of this retrospective study was to determine optimal settings for coronary CT angiography (CCTA). (2) Methods: Thirty patients (eight female, mean age 63 ± 13 years) underwent PCD-CCTA in a high-pitch mode. Images were reconstructed using three different kernels and four sharpness levels (Br36/40/44/48, Bv36/40/44/48, and Qr36/40/44/48). To analyze objective image quality, the attenuation, image noise, contrast-to-noise ratio (CNR), and vessel sharpness were quantified in proximal and distal coronaries. For subjective image quality, two blinded readers assessed image noise, visually sharp reproduction of coronaries, and the overall image quality using a five-point Likert scale. (3) Results: Attenuation, image noise, CNR, and vessel sharpness significantly differed across kernels (all p < 0.001), with the Br-kernel reaching the highest attenuation. With increasing kernel sharpness, image noise and vessel sharpness increased, whereas CNR continuously decreased. Reconstruction with Br-kernel generally had the highest CNR (Br > Bv > Qr), except Bv-kernel had a superior CNR at sharpness level 40. Bv-kernel had significantly higher vessel sharpness than Br- and Qr-kernel (p < 0.001). Subjective image quality was rated best for kernels Bv40 and Bv36, followed by Br36 and Qr36. (4) Conclusion: Reconstructions with kernel Bv40 are beneficial to achieve optimal image quality in spectral high-pitch CCTA using PCD-CT.