Federico Olivieri

Dr. Federico Olivieri

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 May 2021 in Nanoscale
Verified
Journal Article
Open access
PDF file
FOFederico Olivieri
Federico Olivieri
Rachele CastaldoRachele Castaldo
Rachele Castaldo
MCMariacristina Cocca
Mariacristina Cocca
Gennaro GentileGennaro Gentile
Gennaro Gentile
Marino LavorgnaMarino Lavorgna
Marino Lavorgna
Mesoporous silica nanoparticles with properly designed textural properties and tailored release of corrosion inhibitors are highly efficient smart carriers for advanced anticorrosive nanocomposite coatings.

29 March 2017 in Light: Science & Applications
Verified
Journal Article
Open access
PDF file
VBVittorio Bianco
Vittorio Bianco
BMBiagio Mandracchia
Biagio Mandracchia
VMValentina Marchesano
Valentina Marchesano
VPVito Pagliarulo
Vito Pagliarulo
FOFederico Olivieri
Federico Olivieri
PFPietro Ferraro
Pietro Ferraro
Lab-on-a-Chip (LoC) devices are extremely promising in that they enable diagnostic functions at the point-of-care. Within this scope, an important goal is to design imaging schemes that can be used out of the laboratory. In this paper, we introduce and test a pocket holographic slide that allows digital holography microscopy to be performed without an interferometer setup. Instead, a commercial off-the-shelf plastic chip is engineered and functionalized with this aim. The microfluidic chip is endowed with micro-optics, that is, a diffraction grating and polymeric lenses, to build an interferometer directly on the chip, avoiding the need for a reference arm and external bulky optical components. Thanks to the single-beam scheme, the system is completely integrated and robust against vibrations, sharing the useful features of any common path interferometer. Hence, it becomes possible to bring holographic functionalities out of the lab, moving complexity from the external optical apparatus to the chip itself. Label-free imaging and quantitative phase contrast mapping of live samples are demonstrated, along with flexible refocusing capabilities. Thus, a liquid volume can be analyzed in one single shot with no need for mechanical scanning systems.

5 May 2017 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
SCSara Coppola
Sara Coppola
Giuseppe NastiGiuseppe Nasti
Giuseppe Nasti
MTMichele Todino
Michele Todino
FOFederico Olivieri
Federico Olivieri
VVVeronica Vespini
Veronica Vespini
PFPietro Ferraro
Pietro Ferraro

4 January 2018 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
LMLaura Mecozzi
Laura Mecozzi
OGOriella Gennari
Oriella Gennari
SCSara Coppola
Sara Coppola
FOFederico Olivieri
Federico Olivieri
RRRomina Rega
Romina Rega
SGSimonetta Grilli
Simonetta Grilli

14 November 2023 in Polymer Composites
Verified
Journal Article
Open access
FOFederico Olivieri
Federico Olivieri
RARoberto Avolio
Roberto Avolio
Gennaro GentileGennaro Gentile
Gennaro Gentile
AMAnnamaria Mazzone
Annamaria Mazzone
Rosanna RizziRosanna Rizzi
Rosanna Rizzi
Marino LavorgnaMarino Lavorgna
Marino Lavorgna
Acrylonitrile‐butadiene‐styrene (ABS) based composites with a high content of tungsten and bismuth oxide were developed using an innovative process to obtain lead‐free x‐ray shielding materials. ABS was chosen for its good mechanical properties and its widespread availability as a recycled material. The composites underwent flexural tests, Shore D hardness tests, thermogravimetric and morphological analysis, and their x‐ray attenuation properties were determined through numerical simulations and experimental measurements. Despite their high filler content (up to 75 wt%), the composites showed good filler dispersion within the polymeric matrix and maintained their mechanical properties. Across the investigated energy range (50–150 kV), the lead equivalence for x‐ray shielding was achieved with composite plates containing 75 wt% of tungsten and bismuth oxide, at thickness values corresponding to a weight increase of only 29% and 36%, respectively, in comparison to lead. These findings pave the way for a new generation of lead‐free x‐ray shielding materials. Moreover, their mechanical properties, including flexibility for potential application in wearable personal protective equipment, can be tailored by adjusting the filler content.Highlights: High filler content lead‐free ABS composites with WO3 and Bi2O3 were developed. They show good polymer/filler interfacial adhesion and flexural properties. Numerical simulations of their x‐ray shielding properties were performed. Experimental tests with polychromatic sources confirmed good x‐ray attenuation. Results pave the way for the development of new lead‐free x‐ray shielding systems.

11 May 2024 in Journal of Colloid and Interface Science
Verified
Journal Article
Open access
NFNoemi Faggio
Noemi Faggio
FOFederico Olivieri
Federico Olivieri
IBIrene Bonadies
Irene Bonadies
Gennaro GentileGennaro Gentile
Gennaro Gentile
Veronica AmbrogiVeronica Ambrogi
Veronica Ambrogi
Pierfrancesco CerrutiPierfrancesco Cerruti
Pierfrancesco Cerruti
Electroactive coatings for smart wearable textiles based on a furan bio-epoxy monomer (BOMF) crosslinked with isophorone diamine (IPD) and additivated with carbon nanotubes (CNTs) are reported herein. The effect of BOMF/IPD molar ratio on the curing reaction, as well as on the properties of the crosslinked resins was first assessed, and it was found that 1.5:1 BOMF/IPD molar ratio provided higher heat of reaction, glass transition temperature, and mechanical performance. The resin was then modified with CNT to prepare electrically conductive nanocomposite films, which exhibited conductivity values increased by eight orders of magnitude upon addition of 5 phr of CNTs. The epoxy/CNT nanocomposites were finally applied as coatings onto a cotton fabric to develop electrically conductive, hydrophobic and breathable textiles. Notably, the integration of CNTs imparted efficient and reversible electrothermal behavior to the cotton fabric, showcasing its potential application in smart and comfortable wearable electronic devices.