Perovskite is attracting considerable interest because of its excellent semiconducting properties and optoelectronic performance. In particular, lead perovskites have been used extensively in photovoltaic, photodetectors, thin-film transistors, and various electronic applications. On the other hand, the elimination of lead is essential because of its strong toxicity. This paper reports the synthesis of lead-free calcium titanate perovskite (CaTiO3) using a solution-processed combustion method. The chemical and morphological properties of CaTiO3 were examined as a function of its thickness by scanning electron microscopy, X-ray diffraction (XRD), atomic force microscopy, X-ray photoelectron spectroscopy, and ultraviolet–visible spectrophotometry. The analysis showed that thicker films formed by a cumulative coating result in larger grains and more oxygen vacancies. Furthermore, thickness-dependent hysteresis behaviors were examined by fabricating a metal-CaTiO3-metal structure. The electrical hysteresis could be controlled over an extremely low voltage operation, as low as 100 mV, by varying the grain size and oxygen vacancies.
To increase the human lifespan, healthcare monitoring devices that diagnose diseases and check body conditions have attracted considerable interest. Commercial AgCl-based wet electrodes with the advantages of high conductivity and strong adaptability to human skin are considered the most frequently used electrode material for healthcare monitoring. However, commercial AgCl-based wet electrodes, when exposed for a long period, cause an evaporation of organic solvents, which could reduce the signal-to-noise ratio of biosignals and stimulate human skin. In this context, we demonstrate a dry electrode for a poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS)-based blended polymer electrode using a combination of PEDOT:PSS, waterborne polyurethane (WPU) and ethylene glycol (EG) that could be reused for a long period of time to detect electrocardiography (ECG) and electromyography (EMG). Both ECG and EMG are reliably detected by the wireless real-time monitoring system. In particular, the proposed dry electrode detects biosignals without deterioration for over 2 weeks. Additionally, a double layer of a polyimide (PI) substrate and fluorinated polymer CYTOP induces the strong waterproof characteristics of external liquids for the proposed dry electrodes, having a low surface energy of 14.49 mN/m. In addition, the proposed electrode has excellent degradability in water; it dissolves in hot water at 60 °C.