With the development of technology, systems gravitate towards increasing in their complexity, miniaturization, and level of automation. Amongst these systems, ultrasonic devices have adhered to this trend of advancement. Ultrasonic systems require transducers to generate and sense ultrasonic signals. These transducers heavily impact the system’s performance. Advancements in microelectromechanical systems have led to the development of micromachined ultrasonic transducers (MUTs), which are utilized in miniaturized ultrasound systems. Piezoelectric micromachined ultrasonic transducers (PMUTs) exhibit higher capacitance and lower electrical impedance, which enhances the transducer’s sensitivity by minimizing the effect of parasitic capacitance and facilitating their integration with low-voltage electronics. PMUTs utilize high-yield batch microfabrication with the use of thin piezoelectric films. The deposition of thin piezoelectric material compatible with complementary metal-oxide semiconductors (CMOS) has opened novel avenues for the development of miniaturized compact systems with the same substrate for application and control electronics. PMUTs offer a wide variety of applications, including medical imaging, fingerprint sensing, range-finding, energy harvesting, and intrabody and underwater communication links. This paper reviews the current research and recent advancements on PMUTs and their applications. This paper investigates in detail the important transduction metrics and critical design parameters for high-performance PMUTs. Piezoelectric materials and microfabrication processes utilized to manufacture PMUTs are discussed. Promising PMUT applications and outlook on future advancements are presented.
Conventional sensor systems employ single-transduction technology where they respond to an input stimulus and transduce the measured parameter into a readable output signal. As such, the technology can only provide limited corresponding data of the detected parameters due to relying on a single transformed output signal for information acquisition. This limitation commonly results in the need for utilizing sensor array technology to detect targeted parameters in complex environments. Multi-transduction-mechanism technology, on the other hand, may combine more than one transduction mechanism into a single structure. By employing this technology, sensors can be designed to simultaneously distinguish between different input signals from complex environments for greater degrees of freedom. This allows a multi-parameter response, which results in an increased range of detection and improved signal-to-noise ratio. In addition, utilizing a multi-transduction-mechanism approach can achieve miniaturization by reducing the number of required sensors in an array, providing further miniaturization and enhanced performance. This paper introduces the concept of multi-transduction-mechanism technology by exploring different candidate combinations of fundamental transduction mechanisms such as piezoresistive, piezoelectric, triboelectric, capacitive, and inductive mechanisms.
This work presents the first fabrication and experimental validation of a novel electrode design approach for enhancing the mass sensitivity of Quartz Crystal Microbalances (QCMs). The development of unique QCM electrode configurations includes a study of mass loading area distribution and its impact on resonant frequency shift, a key parameter that defines mass sensing performance. Finite Element Analysis (FEA) is conducted to identify areas of opportunity where localized energy trapping occurs and simulate the sensing performances of the configured electrode topologies compared to the conventional circular design. Theoretical models are experimentally validated through the fabrication of 5 MHz QCM sensors with non-conventional designs and the utilization of an automated controlled environment and sensor readout system. The unique QCMs presented herein exhibit noticeably higher resonant frequency shifts in response to variations in water vapor concentration, where the observed shift in frequency serves as an indicator for sensing performance. Experimental results reveal that unique topologies based on the novel Distribution of Area for Improving mass Sensitivity (DAIS) electrode design approach, featuring patterns of annularly distributed small electrodes, effectively utilize the energy trapping effect and outperform the conventional QCM design.
29 October 2024 in IEEE Transactions on Electron Devices
A new set of capacitive-based resonators is introduced in this work that utilizes a unique configured boundaries approach. The proposed design strategy is utilized to develop and characterize three circular resonators as proof-of-concept with strategically configured boundaries. For a fair comparison, the introduced novel resonators along with a reference conventional structure are fabricated using a commercially available fabrication technique, PolyMUMPs. The effects of the presented approach on plate deflection and electromechanical coupling coefficient are demonstrated through finite element analysis (FEA) using COMSOL Multiphysics as well as experimental characterizations. The fabricated devices are electrically evaluated. The white light interferometry is further used for deflection measurements. The device performance evaluations illustrate a robust control of the resonator’s plate stiffness and deflection while maintaining the same dimensions. Experimental evaluations demonstrate an enhanced deflection profile of the plate, which significantly increases the average deflection by up to 50% compared to the conventional resonator developed with the same dimensions and fabrication process. Furthermore, it is observed that using the proposed approach reduces the pull-in voltage by up to 17% compared to the conventional resonators while preserving the resonant frequency within $\pm$ 150 kHz.