With the development of technology, systems gravitate towards increasing in their complexity, miniaturization, and level of automation. Amongst these systems, ultrasonic devices have adhered to this trend of advancement. Ultrasonic systems require transducers to generate and sense ultrasonic signals. These transducers heavily impact the system’s performance. Advancements in microelectromechanical systems have led to the development of micromachined ultrasonic transducers (MUTs), which are utilized in miniaturized ultrasound systems. Piezoelectric micromachined ultrasonic transducers (PMUTs) exhibit higher capacitance and lower electrical impedance, which enhances the transducer’s sensitivity by minimizing the effect of parasitic capacitance and facilitating their integration with low-voltage electronics. PMUTs utilize high-yield batch microfabrication with the use of thin piezoelectric films. The deposition of thin piezoelectric material compatible with complementary metal-oxide semiconductors (CMOS) has opened novel avenues for the development of miniaturized compact systems with the same substrate for application and control electronics. PMUTs offer a wide variety of applications, including medical imaging, fingerprint sensing, range-finding, energy harvesting, and intrabody and underwater communication links. This paper reviews the current research and recent advancements on PMUTs and their applications. This paper investigates in detail the important transduction metrics and critical design parameters for high-performance PMUTs. Piezoelectric materials and microfabrication processes utilized to manufacture PMUTs are discussed. Promising PMUT applications and outlook on future advancements are presented.
Conventional sensor systems employ single-transduction technology where they respond to an input stimulus and transduce the measured parameter into a readable output signal. As such, the technology can only provide limited corresponding data of the detected parameters due to relying on a single transformed output signal for information acquisition. This limitation commonly results in the need for utilizing sensor array technology to detect targeted parameters in complex environments. Multi-transduction-mechanism technology, on the other hand, may combine more than one transduction mechanism into a single structure. By employing this technology, sensors can be designed to simultaneously distinguish between different input signals from complex environments for greater degrees of freedom. This allows a multi-parameter response, which results in an increased range of detection and improved signal-to-noise ratio. In addition, utilizing a multi-transduction-mechanism approach can achieve miniaturization by reducing the number of required sensors in an array, providing further miniaturization and enhanced performance. This paper introduces the concept of multi-transduction-mechanism technology by exploring different candidate combinations of fundamental transduction mechanisms such as piezoresistive, piezoelectric, triboelectric, capacitive, and inductive mechanisms.
Piezoelectric micromachined ultrasonic transducers (PMUTs) traditionally operate at a single frequency, requiring physical modifications to alter their operational frequency. In ultrasonic applications such as diagnostic imaging, the working frequency is critical in determining resolution and detection range. Dual-electrode PMUTs present a promising alternative to conventional designs, enabling multi-frequency operation by activating distinct resonant modes through tailored electrode configurations and actuations. This study details the design, fabrication, and characterization of three dual-electrode PMUT geometries: circular, square, and rectangular membranes. Fabricated using the PiezoMUMPs process, these geometries feature identical material properties and membrane areas. Their electromechanical performance was evaluated through finite element simulations and experimental methods, focusing on metrics such as electromechanical coupling coefficient (EMCC), resonant frequencies, and membrane displacement. A comparative performance analysis across the geometries is presented. Multi-frequency operation was achieved using a dual-electrode configuration with an outer ring electrode and an inner disk electrode, allowing independent activation of two resonant modes. These findings highlight the potential of dual-electrode PMUTs to enhance multi-frequency operation, especially in ultrasonic imaging and related applications.
Multi-frequency operation in ultrasonic transducers balances the trade-off between resolution and penetration depth in ultrasonic imaging. Single top-electrode PMUTs couple strongly to the fundamental mode but weakly to higher-order modes because uniform electrode coverage does not conform to the higher-mode strain profile. Dual concentric ring-and-disk (C–C) electrodes access multiple modes yet reduce fundamental-mode coupling due to misalignment between the segmented coverage and the fundamental strain profile. In this work a circular square (C-Sq) dual top electrode is introduced to strengthen coupling in both the fundamental and higher order modes for multifrequency operation. The configuration pairs a circular outer electrode with a square inner electrode on a circular membrane. The topology aligns with the strain profiles of the fundamental and a selected higher mode enabling mode selective excitation by electrode switching. The proposed C-Sq dual electrode design and reference single electrode and dual electrode concentric ring and disk (C-C) devices were fabricated using the PiezoMUMPs multi-user MEMS process for fair comparison. Electrical impedance analysis, laser doppler vibrometry, and acoustic measurements show a 37% increase in fundamental mode electromechanical coupling relative to C-C dual electrode PMUT and a 27% improvement for the higher mode relative to single electrode PMUTs. Membrane displacement increases by 67% and acoustic pressure at the fundamental resonance is enhanced by 13%. The proposed C-Sq PMUT supports efficient, mode selective multifrequency operation for biomedical imaging and sensing.[2025-0152]
Multifrequency operation in micromachined ultrasonic transducers, enabled by targeted excitation of specific vibrational modes, has emerged as an attractive approach for achieving tunable performance and configurability, well-suited for advanced ultrasound imaging and therapeutic applications. This paper presents a dual-electrode rectangular piezoelectric micromachined ultrasonic transducer (PMUT) designed for efficient dual-frequency operation through mode selective actuation. The proposed architecture employs segmented electrodes that are spatially aligned with the strain distributions of two distinct flexural modes, enabling selective excitation of Mode 1 (fundamental) and Mode 3 (higher order) through appropriate electrode actuation. Finite element simulations and impedance analysis were used to guide the electrode configuration and validate the mode-selective behavior. The dual-mode PMUT was fabricated alongside a conventional single-electrode PMUT using identical membrane dimensions and material stack for direct comparison. Comprehensive electrical and underwater acoustic characterization confirmed that the conventional PMUT is limited to single-frequency operation at the fundamental resonance. In contrast, the proposed design achieved a substantial improvement in higher-order performance, with a threefold increase in acoustic pressure at Mode 3 compared to the conventional device. These results demonstrate that mode-aligned electrode segmentation enables efficient dual-mode operation without added fabrication complexity, making the design highly suitable for multifrequency ultrasonic applications such as biomedical imaging and sensing.