Yu-Jie Tan

Dr. Yu-Jie Tan

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 August 2025 in Classical and Quantum Gravity
Verified
Journal Article
Closed access
JLJun Luo
Jun Luo
SBShaojun Bai
Shaojun Bai
YBYanzheng Bai
Yanzheng Bai
LCLin Cai
Lin Cai
HDHao Dang
Hao Dang
JMJianwei Mei
Jianwei Mei
TianQin is a future space-based gravitational wave (GW) observatory targeting the frequency window of 10−4–1 Hz. A large variety of GW sources are expected in this frequency band, including the merger of massive black hole binaries, the inspiral of extreme/intermediate mass ratio systems, stellar-mass black hole binaries, Galactic compact binaries, and so on. TianQin will consist of three Earth orbiting satellites on nearly identical orbits with orbital radii of about 105 km. The satellites will form a normal triangle constellation whose plane is nearly perpendicular to the ecliptic plane. The TianQin project has been progressing smoothly following the ‘0123’ technology roadmap. In step ‘0’, the TianQin laser ranging station has been constructed and it has successfully ranged to all the five retro-reflectors on the Moon. In step ‘1’, the drag-free control technology has been tested and demonstrated using the TianQin-1 satellite. In step ‘2’, the inter-satellite laser interferometry technology will be tested using the pair of TianQin-2 satellites. The TianQin-2 mission has been officially approved and the satellites will be launched around 2026. In step ‘3’, i.e. the TianQin-3 mission, three identical satellites will be launched around 2035 to form the space-based GW detector, TianQin, and to start GW detection in space.

22 August 2019 in Physical Review D
Verified
Journal Article
Closed access
PDF file
XLXiao-Yu Lu
Xiao-Yu Lu
YTYu-Jie Tan
Yu-Jie Tan
CSChenggang Shao
Chenggang Shao
Time-delay interferometry is put forward to improve the signal-to-noise ratio of space-borne gravitational wave detectors by canceling the large laser phase noise with different combinations of measured data. Based on the Michelson data combination, the sensitivity function of the detector can be obtained by averaging the all-sky wave source positions. At present, there are two main methods to encode gravitational wave signal into detector. One is to adapt gravitational wave polarization angle depending on the arm orientation in the gravitational wave frame, and the other is to divide the gravitational wave signal into plus and cross polarizations in the detector frame. Although there are some attempts using the first method to provide the analytical expression of sensitivity function, only a semianalytical one could be obtained. Here, starting with the second method, we demonstrate the equivalence of both methods. First time to obtain the full analytical expression of sensitivity function, which provides a fast and accurate mean to evaluate and compare the performance of different space-borne detectors, such as LISA and TianQin.

17 March 2021 in Physical Review D
Verified
Journal Article
Closed access
PDF file
PWPan pan Wang
Pan pan Wang
YTYu-Jie Tan
Yu-Jie Tan
Wei-Liang QianWei-Liang Qian
Wei-Liang Qian
CSChenggang Shao
Chenggang Shao
The principal aim of the space-based gravitational wave detectors is to explore the gravitational waves in the 0.1 mHz-1 Hz frequency band. To maximize the potential capability of the experimental apparatus regarding the instrument performance, one needs to acquire accurate information on its sensitivity limit. The sensitivity curve in question, by definition, depends on the amplitudes of signal and noise involved in the measurement. In this work, we explicitly derive, under rather universal assumptions irrelevant to the detailed form of the time-delay interferometry combination, general results of the sensitivity functions. The key feature of the present approach is that both the all-sky and polarization average can be factorized and henceforth evaluated analytically. The resultant expressions are then applied to a variety of time-delay interferometry combinations, inclusively for the optimal channels. In particular, the asymptotical forms of the sensitivity functions are obtained at the high and low frequency limits, and the subsequential implications are analyzed. When compared with the approaches in terms of numerical integration, the obtained formulism furnishes a more straightforward as well as efficient access to the relevant signal noise ratios for the spaceborne gravitational wave detectors.

2 July 2021 in Physical Review D
Verified
Journal Article
Closed access
PDF file
PWPan pan Wang
Pan pan Wang
YTYu-Jie Tan
Yu-Jie Tan
Wei-Liang QianWei-Liang Qian
Wei-Liang Qian
CSChenggang Shao
Chenggang Shao
Direct observation of gravitational waves offers us numerous novel possibilities to further explore the Universe. In practice, the efficiency of the experimental facility for a given gravitational wave source can be measured in terms of the sensitivity function of the instrument. The latter essentially indicates the least incident amplitude required in order to achieve the desired level of the signal-to-noise ratio. Among others, the resultant sensitivity function depends on the specific polarization state of the incident gravitational wave as well as the spatial layout of the detector and its orientation to the wave source. Theoretically, Einstein’s general relativity predicts two tensor polarization modes, from a total of six possible modes arising from an arbitrary perturbation of the spacetime metric. Therefore, in this context, the feasibility of measuring nontensorial polarization states provides access to an alternative theory of gravity. In the present study, we analytically evaluate the response functions for arbitrary time-delay interferometry combinations while enumerating all possible polarization modes. The derivation is accomplished by separating the average on the all-sky solid angle from the remaining expression, which, in turn, gives rise to a few factors independent of the time-delay interferometry combination in question. Moreover, we applied the obtained results to the LISA and TianQin missions, and the asymptotic behavior of the resultant sensitivity functions is analyzed and discussed. Among others, it is observed that, for Sagnac combinations, the averaged response function of the breathing mode attains zero at specific discrete frequencies. Such a frequency value corresponds to a multiple of the reciprocal of the one-way light propagation time along the detector arm, irrelevant to the orientation of the wave source. For all six polarization modes, the present findings can be readily applied to an arbitrary time-delay interferometry combination with improved efficiency and accuracy.

1 October 2021 in Physical Review D
Verified
Journal Article
Closed access
PDF file
PWPan pan Wang
Pan pan Wang
YTYu-Jie Tan
Yu-Jie Tan
Wei-Liang QianWei-Liang Qian
Wei-Liang Qian
CSChenggang Shao
Chenggang Shao
The ongoing development of the space-based laser interferometer missions is aiming at unprecedented gravitational wave detections in the millihertz frequency band. The spaceborne nature of the experimental setups leads to a degree of subtlety regarding the otherwise overwhelming laser frequency noise. The cancellation of the latter is accomplished through the time-delay interferometry technique. Moreover, to eventually achieve the desired noise level, the phase fluctuations of the onboard ultrastable oscillator must also be suppressed. This can be fulfilled by introducing sideband signals which, in turn, give rise to an improved cancellation scheme accounting for the clock-jitter noise. Nonetheless, for certain Sagnac-type interferometry layouts, it can be shown that resultant residual clock noise found in the literature can be further improved. In this regard, we propose refined cancellation combinations for two specific clock noise patterns. This is achieved by employing the so-called geometric time-delay interferometry interpretation. It is shown that for specific Sagnac combinations, the residual noise diminishes significantly to attain the experimentally acceptable sensitivity level. Moreover, we argue that the derived combination, in addition to the existing ones in the literature, furnishes a general-purpose cancellation scheme that serves for arbitrary time-delay interferometry combinations. The subsequential residual noise will only involve factors proportional to the commutators between the delay operators. Our arguments reside in the form of the clock noise expressed in terms of the coefficients of the generating set of the first module of syzygies, the linear combination of which originally constitutes the very solution for laser noise reduction.

22 August 2022 in Metrologia
Verified
Journal Article
Closed access
YXYao-Yao Xu
Yao-Yao Xu
JCJia-Feng Cui
Jia-Feng Cui
KQKun Qi
Kun Qi
LCLe-Le Chen
Le-Le Chen
XDXiao-Bing Deng
Xiao-Bing Deng
ZHZhongkun Hu
Zhongkun Hu
Atom interferometry provides an important method of high-precision absolute gravity measurement. As absolute gravimeters, various systematic errors of atom gravimeters have been identified and evaluated. Here a comprehensive evaluation of systematic errors for a transportable atom gravimeter Huazhong University of Science and Technology-Quantum Gravimeter (HUST-QG) is presented. HUST-QG exhibited a short-term sensitivity of 24 μGal Hz−1/2 and a combined uncertainty of 3 μGal. The operation and evaluation of HUST-QG for transportable gravity measurements during the 10th International Comparison of Absolute Gravimeters are discussed. And the degree of equivalence for HUST-QG in this comparison is 1.3 μGal, which supports our evaluation.