This paper presents a simplified zero-dimensional mathematical model for a self-humidifying proton exchange membrane (PEM) fuel cell stack of 1 kW. The model incorporates major electric and thermodynamic variables and parameters involved in the operation of the PEM fuel cell under different operational conditions. Influence of each of these parameters and variables upon the operation and the performance of the PEM fuel cell are investigated. The mathematical equations are modeled by using Matlab–Simulink tools in order to simulate the operation of the developed model with a commercial available 1 kW horizon PEM fuel cell stack (H-1000), which is used for the purposes of model validation and tuning of the developed model. The model can be extrapolated to higher wattage fuel cells of similar arrangements. New equation is presented to determine the impact of using air to supply the PEM fuel cell instead of pure oxygen upon the concentration losses and the output voltage when useful current is drawn from it.
The operation and the development of power system networks introduce new types of stability problems. The effect of the power generation and consumption on the frequency of the power system can be described as a demand/generation imbalance resulting from a sudden increase/decrease in the demand and/or generation. This paper investigates the impact of a loss of generation on the transient behaviour of the power grid frequency. A simplified power system model is proposed to examine the impact of change of the main generation system parameters (system inertia, governor droop setting, load damping constant, and the high-pressure steam turbine power fraction), on the primary frequency response in responding to the disturbance of a 1.32 GW generation loss on the UK power grid. Various rates of primary frequency responses are simulated via adjusting system parameters of the synchronous generators to enable the controlled generators providing a fast-reliable primary frequency response within 10 s after a loss of generation. It is concluded that a generation system inertia and a governor droop setting are the most dominant parameters that effect the system frequency response after a loss of generation. Therefore, for different levels of generation loss, the recovery rate will be dependent on the changes of the governor droop setting values. The proposed model offers a fundamental basis for a further investigation to be carried on how a power system will react during a secondary frequency response.
Hydrogen is emerging as a key energy carrier in the transition to a low-carbon economy. This study reviews blue and green hydrogen, analysing their production technologies, environmental impacts, economic viability and global deployment trends. Blue hydrogen, derived from natural gas, coal or biomass with carbon capture, utilisation and storage, offers a transitional pathway by reducing emissions relative to unabated fossil routes, but its benefits depend on high CO2 capture efficiencies and strict methane leakage control. Green hydrogen, produced via renewable-powered electrolysis and advanced thermochemical, photochemical and photoelectrochemical methods, represents the most sustainable long-term solution, though it is currently limited by cost and scale. This comparative assessment shows that green hydrogen’s production emissions, in the range of 0.67 kgCO-eq/kgH to 1.74 kgCO2-eq/kgH2, are substantially lower than those of blue hydrogen, in the range of 1.21 kgCO2-eq/kgH2 to 4.56 kgCO2-eq/kgH2, reinforcing its alignment with climate neutrality goals. Global production remains below 1% from low-emission sources, yet momentum is growing, with renewable-rich regions investing in large-scale electrolysers. A long short-term memory forecast suggests that blue hydrogen will dominate in the short term, but green hydrogen will surpass it around 2042. Together, both pathways are essential, blue hydrogen as a bridging option and green hydrogen as the foundation of a sustainable hydrogen economy.
The UK National Grid has placed increased emphasis on the development of Demand Side Response (DSR) tariff mechanisms to manage load at peak times. Refrigeration systems, along with HVAC, are estimated to consume 14% of the UK’s electricity and could have a significant role for DSR application. However, characterized by relatively low individual electrical loads and massive asset numbers, multiple low power refrigerators need aggregation for inclusion in these tariffs. In this paper, the impact of the Demand Side Response (DSR) control mechanisms on food retailing refrigeration systems is investigated. The experiments are conducted in a test-rig built to resemble a typical small supermarket store. The paper demonstrates how the temperature and pressure profiles of the system, the active power and the drawn current of the compressors are affected following a rapid shut down and subsequent return to normal operation as a response to a DSR event. Moreover, risks and challenges associated with primary and secondary Firm Frequency Response (FFR) mechanisms, where the load is rapidly shed at high speed in response to changes in grid frequency, is considered. For instance, measurements are included that show a significant increase in peak inrush currents of approx. 30% when the system returns to normal operation at the end of a DSR event. Consideration of how high inrush currents after a DSR event can produce voltage fluctuations of the supply and we assess risks to the local power supply system.
14 May 2021 in Journal of Thermal Science and Engineering Applications
Commercial food outlets in the UK are responsible for 3% of the UK total energy consumption, with refrigeration systems account for 29% of this total. This highlights the potential and importance of huge energy saving within commercial refrigeration systems. In this paper, a validated model that simulates a commercial refrigeration system installed over 2000 sq. ft to mimic a real express store installed at the Riseholme Refrigeration Research Centre at the University of Lincoln, UK, is developed and presented. The detailed modeling of the display case using a temperature model comprising of three states includes air inside the display case, products, and the evaporator. Additionally, the model presents a holistic view of the whole system with each subsystem cohesively linked together. Further focus has been given on the high-temperature (HT) system due to the high level of installations of this system found in retail commercial refrigeration stores as well as low-temperature (LT) systems featuring doors which decrease the heat transfer from the store into the cases. It is concluded that the trends of the simulation results for the display case temperatures, expansion valve opening degree, suction line pressures, and compressors power consumption, all have high resemblance to the trends of collected data obtained from the Riseholme Refrigeration Research Centre. This supports the validation of the developed model.
3 February 2025 in Journal of Thermal Analysis and Calorimetry